Cargando…

Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes

Bioconversion processes offer many economic, environmental, and societal advantages for production of fuels and chemicals. Successful commercialization of any biotechnology usually requires accurate characterization of cell growth dynamics, substrate conversion and production excretion rates. Despit...

Descripción completa

Detalles Bibliográficos
Autores principales: Stone, Kyle A., He, Q. Peter, Wang, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459910/
https://www.ncbi.nlm.nih.gov/pubmed/30976062
http://dx.doi.org/10.1038/s41598-019-42469-3
_version_ 1783410250500538368
author Stone, Kyle A.
He, Q. Peter
Wang, Jin
author_facet Stone, Kyle A.
He, Q. Peter
Wang, Jin
author_sort Stone, Kyle A.
collection PubMed
description Bioconversion processes offer many economic, environmental, and societal advantages for production of fuels and chemicals. Successful commercialization of any biotechnology usually requires accurate characterization of cell growth dynamics, substrate conversion and production excretion rates. Despite recent advancements in analytical equipment, obtaining accurate measurement of gas component uptake or production rates remains challenging due to their high sensitivity to system pressure or volume changes. Specifically, the consumption and production of various gases will result in changes in system pressure (for batch operations) or off-gas flow rate (for continuous operations). These changes would cause significant errors in the estimated gas component uptake and production rates if they were not accounted for. In this work, we propose two easy-to-implement experimental protocols and associated calculation procedures to obtain accurate measurements of gas component consumption and production rates; one is for batch operation and one is for continuous operation. For depressurized (i.e., system pressure below 1 atm) batch cultures, nitrogen (or other inert gases) is used to repressurize the system to 1 atm before taking sample; while for continuous cultures, He (or other inert gases) is used as an internal tracer to accurately measure off-gas flow rate. The effectiveness and accuracy of the two protocols and associated calculation procedures are demonstrated using several case studies with both abiotic and biotic systems.
format Online
Article
Text
id pubmed-6459910
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-64599102019-04-16 Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes Stone, Kyle A. He, Q. Peter Wang, Jin Sci Rep Article Bioconversion processes offer many economic, environmental, and societal advantages for production of fuels and chemicals. Successful commercialization of any biotechnology usually requires accurate characterization of cell growth dynamics, substrate conversion and production excretion rates. Despite recent advancements in analytical equipment, obtaining accurate measurement of gas component uptake or production rates remains challenging due to their high sensitivity to system pressure or volume changes. Specifically, the consumption and production of various gases will result in changes in system pressure (for batch operations) or off-gas flow rate (for continuous operations). These changes would cause significant errors in the estimated gas component uptake and production rates if they were not accounted for. In this work, we propose two easy-to-implement experimental protocols and associated calculation procedures to obtain accurate measurements of gas component consumption and production rates; one is for batch operation and one is for continuous operation. For depressurized (i.e., system pressure below 1 atm) batch cultures, nitrogen (or other inert gases) is used to repressurize the system to 1 atm before taking sample; while for continuous cultures, He (or other inert gases) is used as an internal tracer to accurately measure off-gas flow rate. The effectiveness and accuracy of the two protocols and associated calculation procedures are demonstrated using several case studies with both abiotic and biotic systems. Nature Publishing Group UK 2019-04-11 /pmc/articles/PMC6459910/ /pubmed/30976062 http://dx.doi.org/10.1038/s41598-019-42469-3 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Stone, Kyle A.
He, Q. Peter
Wang, Jin
Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title_full Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title_fullStr Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title_full_unstemmed Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title_short Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes
title_sort two experimental protocols for accurate measurement of gas component uptake and production rates in bioconversion processes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459910/
https://www.ncbi.nlm.nih.gov/pubmed/30976062
http://dx.doi.org/10.1038/s41598-019-42469-3
work_keys_str_mv AT stonekylea twoexperimentalprotocolsforaccuratemeasurementofgascomponentuptakeandproductionratesinbioconversionprocesses
AT heqpeter twoexperimentalprotocolsforaccuratemeasurementofgascomponentuptakeandproductionratesinbioconversionprocesses
AT wangjin twoexperimentalprotocolsforaccuratemeasurementofgascomponentuptakeandproductionratesinbioconversionprocesses