Cargando…

Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile

To develop a wearable multi-lead electrocardiogram (ECG) measuring system, we fabricated the electrodes and wires by using electrostatic flocking technology on a textile. By using this technology, it was possible to fabricate many electrodes and wires, simultaneously. Also the flocked electrodes and...

Descripción completa

Detalles Bibliográficos
Autores principales: Takeshita, Toshihiro, Yoshida, Manabu, Takei, Yusuke, Ouchi, Atsushi, Hinoki, Akinari, Uchida, Hiroo, Kobayashi, Takeshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459913/
https://www.ncbi.nlm.nih.gov/pubmed/30976016
http://dx.doi.org/10.1038/s41598-019-42027-x
_version_ 1783410251302699008
author Takeshita, Toshihiro
Yoshida, Manabu
Takei, Yusuke
Ouchi, Atsushi
Hinoki, Akinari
Uchida, Hiroo
Kobayashi, Takeshi
author_facet Takeshita, Toshihiro
Yoshida, Manabu
Takei, Yusuke
Ouchi, Atsushi
Hinoki, Akinari
Uchida, Hiroo
Kobayashi, Takeshi
author_sort Takeshita, Toshihiro
collection PubMed
description To develop a wearable multi-lead electrocardiogram (ECG) measuring system, we fabricated the electrodes and wires by using electrostatic flocking technology on a textile. By using this technology, it was possible to fabricate many electrodes and wires, simultaneously. Also the flocked electrodes and wires had stretchability and washing resistance properties. To use dry electrodes, it is important to reduce the influence of motion artifacts (MAs). The results of the experiment with the skin phantom revealed that the contact pressure between the skin and the electrode is an important factor in MA reduction. Then, we conducted experiments with a human body to determine the relationship between the contact pressure and the MAs. Under the pressures of 200 Pa and 500 Pa, MAs were observed. Meanwhile, under the pressures of 1000 Pa, 2000Pa and 4000 Pa, the ECG signals under rest and deep breathing conditions were able to be measured without MAs. Considering the comfortability, the contact pressure from 1000 Pa to 2000 is preferable. Finally, we fabricated the wearable ECG measuring system and succeeded in measuring 18-lead ECG signals. The measured ECG waveform is in good agreement with the ECG waveform measured by a commercial system.
format Online
Article
Text
id pubmed-6459913
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-64599132019-04-16 Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile Takeshita, Toshihiro Yoshida, Manabu Takei, Yusuke Ouchi, Atsushi Hinoki, Akinari Uchida, Hiroo Kobayashi, Takeshi Sci Rep Article To develop a wearable multi-lead electrocardiogram (ECG) measuring system, we fabricated the electrodes and wires by using electrostatic flocking technology on a textile. By using this technology, it was possible to fabricate many electrodes and wires, simultaneously. Also the flocked electrodes and wires had stretchability and washing resistance properties. To use dry electrodes, it is important to reduce the influence of motion artifacts (MAs). The results of the experiment with the skin phantom revealed that the contact pressure between the skin and the electrode is an important factor in MA reduction. Then, we conducted experiments with a human body to determine the relationship between the contact pressure and the MAs. Under the pressures of 200 Pa and 500 Pa, MAs were observed. Meanwhile, under the pressures of 1000 Pa, 2000Pa and 4000 Pa, the ECG signals under rest and deep breathing conditions were able to be measured without MAs. Considering the comfortability, the contact pressure from 1000 Pa to 2000 is preferable. Finally, we fabricated the wearable ECG measuring system and succeeded in measuring 18-lead ECG signals. The measured ECG waveform is in good agreement with the ECG waveform measured by a commercial system. Nature Publishing Group UK 2019-04-11 /pmc/articles/PMC6459913/ /pubmed/30976016 http://dx.doi.org/10.1038/s41598-019-42027-x Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Takeshita, Toshihiro
Yoshida, Manabu
Takei, Yusuke
Ouchi, Atsushi
Hinoki, Akinari
Uchida, Hiroo
Kobayashi, Takeshi
Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title_full Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title_fullStr Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title_full_unstemmed Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title_short Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile
title_sort relationship between contact pressure and motion artifacts in ecg measurement with electrostatic flocked electrodes fabricated on textile
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459913/
https://www.ncbi.nlm.nih.gov/pubmed/30976016
http://dx.doi.org/10.1038/s41598-019-42027-x
work_keys_str_mv AT takeshitatoshihiro relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT yoshidamanabu relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT takeiyusuke relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT ouchiatsushi relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT hinokiakinari relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT uchidahiroo relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile
AT kobayashitakeshi relationshipbetweencontactpressureandmotionartifactsinecgmeasurementwithelectrostaticflockedelectrodesfabricatedontextile