Cargando…

The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence

PURPOSE: The purpose of our study was to investigate the effect of different slice thicknesses and/or interslice gaps on longitudinal and transverse relaxation times (T(1) and T(2)) measured by a multi-dynamic, multi-echo (MDME) sequence. MATERIALS AND METHODS: This retrospective study included nine...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Koung Mi, Choi, Seung Hong, Kim, Hyeonjin, Hwang, Moonjung, Yo, Roh-Eul, Yun, Tae Jin, Kim, Ji-hoon, Sohn, Chul-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460125/
https://www.ncbi.nlm.nih.gov/pubmed/29984783
http://dx.doi.org/10.2463/mrms.mp.2018-0010
_version_ 1783410287505833984
author Kang, Koung Mi
Choi, Seung Hong
Kim, Hyeonjin
Hwang, Moonjung
Yo, Roh-Eul
Yun, Tae Jin
Kim, Ji-hoon
Sohn, Chul-Ho
author_facet Kang, Koung Mi
Choi, Seung Hong
Kim, Hyeonjin
Hwang, Moonjung
Yo, Roh-Eul
Yun, Tae Jin
Kim, Ji-hoon
Sohn, Chul-Ho
author_sort Kang, Koung Mi
collection PubMed
description PURPOSE: The purpose of our study was to investigate the effect of different slice thicknesses and/or interslice gaps on longitudinal and transverse relaxation times (T(1) and T(2)) measured by a multi-dynamic, multi-echo (MDME) sequence. MATERIALS AND METHODS: This retrospective study included nine healthy subjects who underwent MDME sequence (at 3T) with four different combinations of slice thicknesses and/or interslice gaps: slice thickness of 4 mm and interslice gap of 0 mm (TH4/G0), TH4/G1, TH5/G0, and TH5/G1. T(1) and T(2) were measured in various brain regions by a qualified neuroradiologist with 8 years of clinical experience: the frontal white matter (WM), occipital WM, genu, splenium, frontal cortex, thalamus, putamen, caudate head, and cerebrospinal fluid (CSF). The paired samples t-test was used to investigate the effect of different slice thicknesses and interslice gaps (TH4/G0 versus TH4/G1 and TH5/G0 versus TH5/G1). P < 0.013 was considered statistically significant. RESULTS: T(2) in all brain regions and T(1) in the frontal WM, putamen, and CSF did not significantly change for different slice thicknesses and/or gaps (Ps > 0.013). In addition, T(1) in all brain regions of interest did not significantly change between TH4/G0, TH4/G1, TH5/G0 and TH5/G1. However, T(1) in some of the brain regions was higher with TH4/G0 than with TH5/G0 (occipital WM, frontal cortex, and caudate head) and with TH4/G1 than with TH5/G1 (occipital WM, genu, splenium and thalamus, all Ps < 0.013). CONCLUSION: T(2) estimated using the MDME sequence was stable regardless of slice thickness or gap. Although the sequence seems to provide stable relaxation values, identical slice thicknesses need to be used for follow-up to prevent potential T(1) changes.
format Online
Article
Text
id pubmed-6460125
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-64601252019-04-15 The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence Kang, Koung Mi Choi, Seung Hong Kim, Hyeonjin Hwang, Moonjung Yo, Roh-Eul Yun, Tae Jin Kim, Ji-hoon Sohn, Chul-Ho Magn Reson Med Sci Major Paper PURPOSE: The purpose of our study was to investigate the effect of different slice thicknesses and/or interslice gaps on longitudinal and transverse relaxation times (T(1) and T(2)) measured by a multi-dynamic, multi-echo (MDME) sequence. MATERIALS AND METHODS: This retrospective study included nine healthy subjects who underwent MDME sequence (at 3T) with four different combinations of slice thicknesses and/or interslice gaps: slice thickness of 4 mm and interslice gap of 0 mm (TH4/G0), TH4/G1, TH5/G0, and TH5/G1. T(1) and T(2) were measured in various brain regions by a qualified neuroradiologist with 8 years of clinical experience: the frontal white matter (WM), occipital WM, genu, splenium, frontal cortex, thalamus, putamen, caudate head, and cerebrospinal fluid (CSF). The paired samples t-test was used to investigate the effect of different slice thicknesses and interslice gaps (TH4/G0 versus TH4/G1 and TH5/G0 versus TH5/G1). P < 0.013 was considered statistically significant. RESULTS: T(2) in all brain regions and T(1) in the frontal WM, putamen, and CSF did not significantly change for different slice thicknesses and/or gaps (Ps > 0.013). In addition, T(1) in all brain regions of interest did not significantly change between TH4/G0, TH4/G1, TH5/G0 and TH5/G1. However, T(1) in some of the brain regions was higher with TH4/G0 than with TH5/G0 (occipital WM, frontal cortex, and caudate head) and with TH4/G1 than with TH5/G1 (occipital WM, genu, splenium and thalamus, all Ps < 0.013). CONCLUSION: T(2) estimated using the MDME sequence was stable regardless of slice thickness or gap. Although the sequence seems to provide stable relaxation values, identical slice thicknesses need to be used for follow-up to prevent potential T(1) changes. Japanese Society for Magnetic Resonance in Medicine 2018-07-06 /pmc/articles/PMC6460125/ /pubmed/29984783 http://dx.doi.org/10.2463/mrms.mp.2018-0010 Text en © 2018 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Major Paper
Kang, Koung Mi
Choi, Seung Hong
Kim, Hyeonjin
Hwang, Moonjung
Yo, Roh-Eul
Yun, Tae Jin
Kim, Ji-hoon
Sohn, Chul-Ho
The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title_full The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title_fullStr The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title_full_unstemmed The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title_short The Effect of Varying Slice Thickness and Interslice Gap on T(1) and T(2) Measured with the Multidynamic Multiecho Sequence
title_sort effect of varying slice thickness and interslice gap on t(1) and t(2) measured with the multidynamic multiecho sequence
topic Major Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460125/
https://www.ncbi.nlm.nih.gov/pubmed/29984783
http://dx.doi.org/10.2463/mrms.mp.2018-0010
work_keys_str_mv AT kangkoungmi theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT choiseunghong theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT kimhyeonjin theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT hwangmoonjung theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT yoroheul theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT yuntaejin theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT kimjihoon theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT sohnchulho theeffectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT kangkoungmi effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT choiseunghong effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT kimhyeonjin effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT hwangmoonjung effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT yoroheul effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT yuntaejin effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT kimjihoon effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence
AT sohnchulho effectofvaryingslicethicknessandinterslicegapont1andt2measuredwiththemultidynamicmultiechosequence