Cargando…

Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period

OBJECTIVE: This study was performed to observe the effect of radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF) and to explore the risk factors for late recurrence of atrial fibrillation (LRAF) after a single RFCA session. METHODS: In this retrospective stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yubing, Xu, Yanping, Ling, Zhiyu, Chen, Weijie, Su, Li, Du, Huaan, Xiao, Peilin, Liu, Zengzhang, Yin, Yuehui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460609/
https://www.ncbi.nlm.nih.gov/pubmed/30803295
http://dx.doi.org/10.1177/0300060519828522
_version_ 1783410352805904384
author Wang, Yubing
Xu, Yanping
Ling, Zhiyu
Chen, Weijie
Su, Li
Du, Huaan
Xiao, Peilin
Liu, Zengzhang
Yin, Yuehui
author_facet Wang, Yubing
Xu, Yanping
Ling, Zhiyu
Chen, Weijie
Su, Li
Du, Huaan
Xiao, Peilin
Liu, Zengzhang
Yin, Yuehui
author_sort Wang, Yubing
collection PubMed
description OBJECTIVE: This study was performed to observe the effect of radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF) and to explore the risk factors for late recurrence of atrial fibrillation (LRAF) after a single RFCA session. METHODS: In this retrospective study, 243 patients with PAF underwent RFCA and were followed up regularly. RESULTS: At a median follow-up of 37 months after a single procedure, 60.5% of patients maintained sinus rhythm (SR), and at a median follow-up of 42 months after multiple procedures, 74.9% of patients maintained SR. The statistically significant risk factors for LRAF after a single RFCA session were the left atrial diameter (LAD), left inferior pulmonary vein superior–inferior diameter (LIPV SID), PV number variation, circumferential pulmonary vein isolation (CPVI) combined with additional ablation, and early recurrence of atrial fibrillation (ERAF). The best cut-off value for LAD was 35.5 mm. CONCLUSIONS: During a 3-year follow-up, about 70% of the patients with PAF maintained SR. LRAF after a single procedure was associated with the LAD, LIPV SID, PV number variation, CPVI combined with additional ablation, and ERAF.
format Online
Article
Text
id pubmed-6460609
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-64606092019-04-19 Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period Wang, Yubing Xu, Yanping Ling, Zhiyu Chen, Weijie Su, Li Du, Huaan Xiao, Peilin Liu, Zengzhang Yin, Yuehui J Int Med Res Clinical Research Reports OBJECTIVE: This study was performed to observe the effect of radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF) and to explore the risk factors for late recurrence of atrial fibrillation (LRAF) after a single RFCA session. METHODS: In this retrospective study, 243 patients with PAF underwent RFCA and were followed up regularly. RESULTS: At a median follow-up of 37 months after a single procedure, 60.5% of patients maintained sinus rhythm (SR), and at a median follow-up of 42 months after multiple procedures, 74.9% of patients maintained SR. The statistically significant risk factors for LRAF after a single RFCA session were the left atrial diameter (LAD), left inferior pulmonary vein superior–inferior diameter (LIPV SID), PV number variation, circumferential pulmonary vein isolation (CPVI) combined with additional ablation, and early recurrence of atrial fibrillation (ERAF). The best cut-off value for LAD was 35.5 mm. CONCLUSIONS: During a 3-year follow-up, about 70% of the patients with PAF maintained SR. LRAF after a single procedure was associated with the LAD, LIPV SID, PV number variation, CPVI combined with additional ablation, and ERAF. SAGE Publications 2019-02-26 2019-04 /pmc/articles/PMC6460609/ /pubmed/30803295 http://dx.doi.org/10.1177/0300060519828522 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Clinical Research Reports
Wang, Yubing
Xu, Yanping
Ling, Zhiyu
Chen, Weijie
Su, Li
Du, Huaan
Xiao, Peilin
Liu, Zengzhang
Yin, Yuehui
Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title_full Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title_fullStr Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title_full_unstemmed Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title_short Radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
title_sort radiofrequency catheter ablation for paroxysmal atrial fibrillation: outcomes during a 3-year follow-up period
topic Clinical Research Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460609/
https://www.ncbi.nlm.nih.gov/pubmed/30803295
http://dx.doi.org/10.1177/0300060519828522
work_keys_str_mv AT wangyubing radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT xuyanping radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT lingzhiyu radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT chenweijie radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT suli radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT duhuaan radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT xiaopeilin radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT liuzengzhang radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod
AT yinyuehui radiofrequencycatheterablationforparoxysmalatrialfibrillationoutcomesduringa3yearfollowupperiod