Cargando…

Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures

BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal ox...

Descripción completa

Detalles Bibliográficos
Autores principales: Dias, Raylene, Dave, Nandini, Agrawal, Barkha, Baghele, Aarti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460983/
https://www.ncbi.nlm.nih.gov/pubmed/31000891
http://dx.doi.org/10.4103/ija.IJA_653_18
_version_ 1783410420037451776
author Dias, Raylene
Dave, Nandini
Agrawal, Barkha
Baghele, Aarti
author_facet Dias, Raylene
Dave, Nandini
Agrawal, Barkha
Baghele, Aarti
author_sort Dias, Raylene
collection PubMed
description BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal oxygen concentration (Fi−Et)O(2)% in measuring anaesthetic depth in toddlers and preschool children. Primary outcome was to correlate BIS with ETAG-sevo. Secondary outcome was to correlate (Fi−Et)O(2)% with ETAG-sevo and to derive cut-off value of (Fi−Et)O(2)%which corresponds with light planes of anaesthesia [minimum alveolar concentration (MAC <0.6)]. METHODS: Thirty patients between 1 and 5 years of age undergoing short procedures were included. ETAG, MAC, BIS and (Fi−Et)O(2)% were measured at intubation, maintenance phase, last 15 min of surgery, end of surgery, extubation, recovery. Pearson's correlation coefficient was used to measure correlation. Receiver operating characteristic (ROC) curves were used to derive cut-off value of (Fi−Et)O(2)% which corresponded with MAC <0.6. RESULTS: BIS correlated poorly with ETAG at all time intervals. Significant correlation was seen between (Fi−Et)O(2)% and ETAG at intubation (P = 0.042), last 15 min of surgery (P = 0.019) and end of surgery (P = 0.001). Cut-off value >7 was obtained for (Fi−Et)O(2)% corresponding to MAC <0.6 at extubation with area under ROC curve0.955 (95% confidence interval 0.811–0.997), with sensitivity 0.8571 and specificity 1.00. CONCLUSION: BIS was an unreliable measure of anaesthetic depth. (Fi−Et)O(2)% values >7 corresponded with light planes of anaesthesia.
format Online
Article
Text
id pubmed-6460983
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-64609832019-04-18 Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures Dias, Raylene Dave, Nandini Agrawal, Barkha Baghele, Aarti Indian J Anaesth Original Article BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal oxygen concentration (Fi−Et)O(2)% in measuring anaesthetic depth in toddlers and preschool children. Primary outcome was to correlate BIS with ETAG-sevo. Secondary outcome was to correlate (Fi−Et)O(2)% with ETAG-sevo and to derive cut-off value of (Fi−Et)O(2)%which corresponds with light planes of anaesthesia [minimum alveolar concentration (MAC <0.6)]. METHODS: Thirty patients between 1 and 5 years of age undergoing short procedures were included. ETAG, MAC, BIS and (Fi−Et)O(2)% were measured at intubation, maintenance phase, last 15 min of surgery, end of surgery, extubation, recovery. Pearson's correlation coefficient was used to measure correlation. Receiver operating characteristic (ROC) curves were used to derive cut-off value of (Fi−Et)O(2)% which corresponded with MAC <0.6. RESULTS: BIS correlated poorly with ETAG at all time intervals. Significant correlation was seen between (Fi−Et)O(2)% and ETAG at intubation (P = 0.042), last 15 min of surgery (P = 0.019) and end of surgery (P = 0.001). Cut-off value >7 was obtained for (Fi−Et)O(2)% corresponding to MAC <0.6 at extubation with area under ROC curve0.955 (95% confidence interval 0.811–0.997), with sensitivity 0.8571 and specificity 1.00. CONCLUSION: BIS was an unreliable measure of anaesthetic depth. (Fi−Et)O(2)% values >7 corresponded with light planes of anaesthesia. Wolters Kluwer - Medknow 2019-04 /pmc/articles/PMC6460983/ /pubmed/31000891 http://dx.doi.org/10.4103/ija.IJA_653_18 Text en Copyright: © 2019 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Dias, Raylene
Dave, Nandini
Agrawal, Barkha
Baghele, Aarti
Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title_full Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title_fullStr Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title_full_unstemmed Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title_short Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
title_sort correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460983/
https://www.ncbi.nlm.nih.gov/pubmed/31000891
http://dx.doi.org/10.4103/ija.IJA_653_18
work_keys_str_mv AT diasraylene correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures
AT davenandini correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures
AT agrawalbarkha correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures
AT bagheleaarti correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures