Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal ox...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460983/ https://www.ncbi.nlm.nih.gov/pubmed/31000891 http://dx.doi.org/10.4103/ija.IJA_653_18 |
_version_ | 1783410420037451776 |
---|---|
author | Dias, Raylene Dave, Nandini Agrawal, Barkha Baghele, Aarti |
author_facet | Dias, Raylene Dave, Nandini Agrawal, Barkha Baghele, Aarti |
author_sort | Dias, Raylene |
collection | PubMed |
description | BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal oxygen concentration (Fi−Et)O(2)% in measuring anaesthetic depth in toddlers and preschool children. Primary outcome was to correlate BIS with ETAG-sevo. Secondary outcome was to correlate (Fi−Et)O(2)% with ETAG-sevo and to derive cut-off value of (Fi−Et)O(2)%which corresponds with light planes of anaesthesia [minimum alveolar concentration (MAC <0.6)]. METHODS: Thirty patients between 1 and 5 years of age undergoing short procedures were included. ETAG, MAC, BIS and (Fi−Et)O(2)% were measured at intubation, maintenance phase, last 15 min of surgery, end of surgery, extubation, recovery. Pearson's correlation coefficient was used to measure correlation. Receiver operating characteristic (ROC) curves were used to derive cut-off value of (Fi−Et)O(2)% which corresponded with MAC <0.6. RESULTS: BIS correlated poorly with ETAG at all time intervals. Significant correlation was seen between (Fi−Et)O(2)% and ETAG at intubation (P = 0.042), last 15 min of surgery (P = 0.019) and end of surgery (P = 0.001). Cut-off value >7 was obtained for (Fi−Et)O(2)% corresponding to MAC <0.6 at extubation with area under ROC curve0.955 (95% confidence interval 0.811–0.997), with sensitivity 0.8571 and specificity 1.00. CONCLUSION: BIS was an unreliable measure of anaesthetic depth. (Fi−Et)O(2)% values >7 corresponded with light planes of anaesthesia. |
format | Online Article Text |
id | pubmed-6460983 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-64609832019-04-18 Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures Dias, Raylene Dave, Nandini Agrawal, Barkha Baghele, Aarti Indian J Anaesth Original Article BACKGROUND AND AIMS: Measurement of end-tidal anaesthetic gas concentrations (ETAG) is currently a pragmatic indicator for monitoring anaesthetic depth. We aimed to assess the performance of ETAG for sevoflurane (ETAG-sevo) with bispectral index (BIS) and difference between inspired and end-tidal oxygen concentration (Fi−Et)O(2)% in measuring anaesthetic depth in toddlers and preschool children. Primary outcome was to correlate BIS with ETAG-sevo. Secondary outcome was to correlate (Fi−Et)O(2)% with ETAG-sevo and to derive cut-off value of (Fi−Et)O(2)%which corresponds with light planes of anaesthesia [minimum alveolar concentration (MAC <0.6)]. METHODS: Thirty patients between 1 and 5 years of age undergoing short procedures were included. ETAG, MAC, BIS and (Fi−Et)O(2)% were measured at intubation, maintenance phase, last 15 min of surgery, end of surgery, extubation, recovery. Pearson's correlation coefficient was used to measure correlation. Receiver operating characteristic (ROC) curves were used to derive cut-off value of (Fi−Et)O(2)% which corresponded with MAC <0.6. RESULTS: BIS correlated poorly with ETAG at all time intervals. Significant correlation was seen between (Fi−Et)O(2)% and ETAG at intubation (P = 0.042), last 15 min of surgery (P = 0.019) and end of surgery (P = 0.001). Cut-off value >7 was obtained for (Fi−Et)O(2)% corresponding to MAC <0.6 at extubation with area under ROC curve0.955 (95% confidence interval 0.811–0.997), with sensitivity 0.8571 and specificity 1.00. CONCLUSION: BIS was an unreliable measure of anaesthetic depth. (Fi−Et)O(2)% values >7 corresponded with light planes of anaesthesia. Wolters Kluwer - Medknow 2019-04 /pmc/articles/PMC6460983/ /pubmed/31000891 http://dx.doi.org/10.4103/ija.IJA_653_18 Text en Copyright: © 2019 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Dias, Raylene Dave, Nandini Agrawal, Barkha Baghele, Aarti Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title | Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title_full | Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title_fullStr | Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title_full_unstemmed | Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title_short | Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
title_sort | correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired–end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6460983/ https://www.ncbi.nlm.nih.gov/pubmed/31000891 http://dx.doi.org/10.4103/ija.IJA_653_18 |
work_keys_str_mv | AT diasraylene correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures AT davenandini correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures AT agrawalbarkha correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures AT bagheleaarti correlationbetweenbispectralindexendtidalanaestheticgasconcentrationanddifferenceininspiredendtidaloxygenconcentrationasmeasuresofanaestheticdepthinpaediatricpatientspostedforshortsurgicalprocedures |