Cargando…
Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study
BACKGROUND: With the in-depth development of minimally invasive spine surgery in recent years, robot- and computer-assisted technologies have been increasingly used and successfully applied to spinal surgery. MATERIAL/METHODS: We performed a retrospective analysis of 60 patients with grade I or II l...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462172/ https://www.ncbi.nlm.nih.gov/pubmed/30946733 http://dx.doi.org/10.12659/MSM.913124 |
_version_ | 1783410578315804672 |
---|---|
author | Yang, Jun-Song He, Baorong Tian, Fang Liu, Tuan-Jiang Liu, Peng Zhang, Jia-Nan Liu, Shi-Chang Tuo, Yuan Chu, Lei Hao, Ding-Jun |
author_facet | Yang, Jun-Song He, Baorong Tian, Fang Liu, Tuan-Jiang Liu, Peng Zhang, Jia-Nan Liu, Shi-Chang Tuo, Yuan Chu, Lei Hao, Ding-Jun |
author_sort | Yang, Jun-Song |
collection | PubMed |
description | BACKGROUND: With the in-depth development of minimally invasive spine surgery in recent years, robot- and computer-assisted technologies have been increasingly used and successfully applied to spinal surgery. MATERIAL/METHODS: We performed a retrospective analysis of 60 patients with grade I or II lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) from January 2017 to December 2017. A robot-assisted surgical system was used in 30 patients for pedicle screw placement. The other 30 patients underwent fluoroscopy-guided percutaneous pedicle screw placement. RESULTS: There were 130 screws placed under fluoroscopic guidance, with 26.2% penetration of the pedicle wall. There were 130 screws placed in robotic-assisted surgery, with 6.2% penetration of the pedicle wall. Severe screw deviation (Neo grade III) was identified in 4 screws in the fluoroscopy-guided group, while no severe deviation was noted in the robot-assisted group. In the fluoroscopic group, 15.6% of screws penetrated the superior articular process, and 2.1% screws had severe complications (Babu grade III). However, only 5.1% of screws in the robot-assisted group had severe complications. The mean screw insertion angle was significantly greater in the robot-assisted group than in the fluoroscopy-guided group (23.8±6.1° vs. 18.4±7.2°, P=0.017). CONCLUSIONS: Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the following advantages: greater accuracy, lower incidences of screw penetration of the pedicle wall and invasion of the facet joints, and better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis. |
format | Online Article Text |
id | pubmed-6462172 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64621722019-04-26 Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study Yang, Jun-Song He, Baorong Tian, Fang Liu, Tuan-Jiang Liu, Peng Zhang, Jia-Nan Liu, Shi-Chang Tuo, Yuan Chu, Lei Hao, Ding-Jun Med Sci Monit Clinical Research BACKGROUND: With the in-depth development of minimally invasive spine surgery in recent years, robot- and computer-assisted technologies have been increasingly used and successfully applied to spinal surgery. MATERIAL/METHODS: We performed a retrospective analysis of 60 patients with grade I or II lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) from January 2017 to December 2017. A robot-assisted surgical system was used in 30 patients for pedicle screw placement. The other 30 patients underwent fluoroscopy-guided percutaneous pedicle screw placement. RESULTS: There were 130 screws placed under fluoroscopic guidance, with 26.2% penetration of the pedicle wall. There were 130 screws placed in robotic-assisted surgery, with 6.2% penetration of the pedicle wall. Severe screw deviation (Neo grade III) was identified in 4 screws in the fluoroscopy-guided group, while no severe deviation was noted in the robot-assisted group. In the fluoroscopic group, 15.6% of screws penetrated the superior articular process, and 2.1% screws had severe complications (Babu grade III). However, only 5.1% of screws in the robot-assisted group had severe complications. The mean screw insertion angle was significantly greater in the robot-assisted group than in the fluoroscopy-guided group (23.8±6.1° vs. 18.4±7.2°, P=0.017). CONCLUSIONS: Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the following advantages: greater accuracy, lower incidences of screw penetration of the pedicle wall and invasion of the facet joints, and better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis. International Scientific Literature, Inc. 2019-04-04 /pmc/articles/PMC6462172/ /pubmed/30946733 http://dx.doi.org/10.12659/MSM.913124 Text en © Med Sci Monit, 2019 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Yang, Jun-Song He, Baorong Tian, Fang Liu, Tuan-Jiang Liu, Peng Zhang, Jia-Nan Liu, Shi-Chang Tuo, Yuan Chu, Lei Hao, Ding-Jun Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title | Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title_full | Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title_fullStr | Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title_full_unstemmed | Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title_short | Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study |
title_sort | accuracy of robot-assisted percutaneous pedicle screw placement for treatment of lumbar spondylolisthesis: a comparative cohort study |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462172/ https://www.ncbi.nlm.nih.gov/pubmed/30946733 http://dx.doi.org/10.12659/MSM.913124 |
work_keys_str_mv | AT yangjunsong accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT hebaorong accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT tianfang accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT liutuanjiang accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT liupeng accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT zhangjianan accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT liushichang accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT tuoyuan accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT chulei accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy AT haodingjun accuracyofrobotassistedpercutaneouspediclescrewplacementfortreatmentoflumbarspondylolisthesisacomparativecohortstudy |