Cargando…

Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study

PURPOSE: To evaluate laser in situ keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the LASIK procedure were stratified into two groups: FS laser...

Descripción completa

Detalles Bibliográficos
Autores principales: Eldaly, Zeiad H., Abdelsalam, Mahmoud A., Hussein, Mohamed S., Nassr, Mohamed A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462471/
https://www.ncbi.nlm.nih.gov/pubmed/30977320
http://dx.doi.org/10.3341/kjo.2018.0035
_version_ 1783410622187175936
author Eldaly, Zeiad H.
Abdelsalam, Mahmoud A.
Hussein, Mohamed S.
Nassr, Mohamed A.
author_facet Eldaly, Zeiad H.
Abdelsalam, Mahmoud A.
Hussein, Mohamed S.
Nassr, Mohamed A.
author_sort Eldaly, Zeiad H.
collection PubMed
description PURPOSE: To evaluate laser in situ keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the LASIK procedure were stratified into two groups: FS laser-assisted (Allegretto FS-200) and MK flap creation (Moria 2). Flap thickness was determined at five points. The side-cut angle was measured in three directions at the margin interface. LASIK flap assessment was performed one month postoperatively by Spectralis anterior segment optical coherence tomography. RESULTS: Fifty-two patients (93 eyes) were recruited; 49 eyes were stratified to the FS group and 44 eyes to the MK group. The FS group had relatively even flap configurations, and the MK group had meniscus-shaped flaps. Mean differences between planned and actual flap thickness were 12.93 ± 8.89 and 19.91 ± 5.77 µm in the FS and MK groups, respectively. In thin flaps (100 to 110 µm), there was a significant disparity between the two groups (7.80 ± 4.71 and 19.44 ± 4.46 µm in the FS and MK groups, respectively). However, in thicker flaps (130 µm), comparable flap thickness disparity was achieved (18.54 ± 9.52 and 20.83 ± 5.99 µm in the FS and MK groups, respectively). Mean side-cut angle was 74.29 ± 5.79 degrees and 32.34 ± 4.94 degrees in the FS and MK groups, respectively. CONCLUSIONS: Comparable flap thickness predictability was achieved in thicker flaps (130 µm), while the FS laser technique yielded a more predictable result in thinner flaps (100 to 110 µm). Different flap morphology was observed in meniscus flaps in MK-LASIK and flap morphology in FS-LASIK.
format Online
Article
Text
id pubmed-6462471
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-64624712019-04-21 Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study Eldaly, Zeiad H. Abdelsalam, Mahmoud A. Hussein, Mohamed S. Nassr, Mohamed A. Korean J Ophthalmol Original Article PURPOSE: To evaluate laser in situ keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the LASIK procedure were stratified into two groups: FS laser-assisted (Allegretto FS-200) and MK flap creation (Moria 2). Flap thickness was determined at five points. The side-cut angle was measured in three directions at the margin interface. LASIK flap assessment was performed one month postoperatively by Spectralis anterior segment optical coherence tomography. RESULTS: Fifty-two patients (93 eyes) were recruited; 49 eyes were stratified to the FS group and 44 eyes to the MK group. The FS group had relatively even flap configurations, and the MK group had meniscus-shaped flaps. Mean differences between planned and actual flap thickness were 12.93 ± 8.89 and 19.91 ± 5.77 µm in the FS and MK groups, respectively. In thin flaps (100 to 110 µm), there was a significant disparity between the two groups (7.80 ± 4.71 and 19.44 ± 4.46 µm in the FS and MK groups, respectively). However, in thicker flaps (130 µm), comparable flap thickness disparity was achieved (18.54 ± 9.52 and 20.83 ± 5.99 µm in the FS and MK groups, respectively). Mean side-cut angle was 74.29 ± 5.79 degrees and 32.34 ± 4.94 degrees in the FS and MK groups, respectively. CONCLUSIONS: Comparable flap thickness predictability was achieved in thicker flaps (130 µm), while the FS laser technique yielded a more predictable result in thinner flaps (100 to 110 µm). Different flap morphology was observed in meniscus flaps in MK-LASIK and flap morphology in FS-LASIK. The Korean Ophthalmological Society 2019-04 2019-04-08 /pmc/articles/PMC6462471/ /pubmed/30977320 http://dx.doi.org/10.3341/kjo.2018.0035 Text en © 2019 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Eldaly, Zeiad H.
Abdelsalam, Mahmoud A.
Hussein, Mohamed S.
Nassr, Mohamed A.
Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title_full Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title_fullStr Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title_full_unstemmed Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title_short Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study
title_sort comparison of laser in situ keratomileusis flap morphology and predictability by wavelight fs200 femtosecond laser and moria microkeratome: an anterior segment optical coherence tomography study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462471/
https://www.ncbi.nlm.nih.gov/pubmed/30977320
http://dx.doi.org/10.3341/kjo.2018.0035
work_keys_str_mv AT eldalyzeiadh comparisonoflaserinsitukeratomileusisflapmorphologyandpredictabilitybywavelightfs200femtosecondlaserandmoriamicrokeratomeananteriorsegmentopticalcoherencetomographystudy
AT abdelsalammahmouda comparisonoflaserinsitukeratomileusisflapmorphologyandpredictabilitybywavelightfs200femtosecondlaserandmoriamicrokeratomeananteriorsegmentopticalcoherencetomographystudy
AT husseinmohameds comparisonoflaserinsitukeratomileusisflapmorphologyandpredictabilitybywavelightfs200femtosecondlaserandmoriamicrokeratomeananteriorsegmentopticalcoherencetomographystudy
AT nassrmohameda comparisonoflaserinsitukeratomileusisflapmorphologyandpredictabilitybywavelightfs200femtosecondlaserandmoriamicrokeratomeananteriorsegmentopticalcoherencetomographystudy