Cargando…
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
BACKGROUND: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. METHODS: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI o...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462767/ https://www.ncbi.nlm.nih.gov/pubmed/31011608 http://dx.doi.org/10.1016/j.plabm.2019.e00121 |
_version_ | 1783410635705417728 |
---|---|
author | Lamrabat, Somiya Lyagoubi, Amina Bouayadi, Ouardia Elmalki, Jalila Elkouche, Khadija Bensalah, Mohammed Choukri, Mohammed |
author_facet | Lamrabat, Somiya Lyagoubi, Amina Bouayadi, Ouardia Elmalki, Jalila Elkouche, Khadija Bensalah, Mohammed Choukri, Mohammed |
author_sort | Lamrabat, Somiya |
collection | PubMed |
description | BACKGROUND: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. METHODS: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. RESULTS: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect = −0,5625 + 0,9917 XIntegra with a correlation coefficient r(2) = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. CONCLUSION: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. |
format | Online Article Text |
id | pubmed-6462767 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-64627672019-04-22 Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay Lamrabat, Somiya Lyagoubi, Amina Bouayadi, Ouardia Elmalki, Jalila Elkouche, Khadija Bensalah, Mohammed Choukri, Mohammed Pract Lab Med Article BACKGROUND: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. METHODS: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. RESULTS: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect = −0,5625 + 0,9917 XIntegra with a correlation coefficient r(2) = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. CONCLUSION: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. Elsevier 2019-03-22 /pmc/articles/PMC6462767/ /pubmed/31011608 http://dx.doi.org/10.1016/j.plabm.2019.e00121 Text en © 2019 Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Lamrabat, Somiya Lyagoubi, Amina Bouayadi, Ouardia Elmalki, Jalila Elkouche, Khadija Bensalah, Mohammed Choukri, Mohammed Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title | Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_full | Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_fullStr | Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_full_unstemmed | Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_short | Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_sort | comparison between roche integra 400 plus and abbott architect ci8200 in alanine aminotransferase assay |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462767/ https://www.ncbi.nlm.nih.gov/pubmed/31011608 http://dx.doi.org/10.1016/j.plabm.2019.e00121 |
work_keys_str_mv | AT lamrabatsomiya comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT lyagoubiamina comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT bouayadiouardia comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT elmalkijalila comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT elkouchekhadija comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT bensalahmohammed comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT choukrimohammed comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay |