Cargando…

Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein

BACKGROUND: The ECG characteristics of the distal coronary venous system ventricular arrhythmias (VAs) share common features with VAs arising from the aortic cusps or the endocardial left ventricular outflow tract (LVOT) beneath the cusps. The purpose of this study was to identify specific electroca...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Teng, Xu, Qiong, Zhan, Xian-zhang, Xue, Yu-mei, Liao, Hong-tao, Li, Yi-fu, Letsas, Konstantinos P., Wu, Shu-lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6466655/
https://www.ncbi.nlm.nih.gov/pubmed/30987582
http://dx.doi.org/10.1186/s12872-019-1064-9
_version_ 1783411149301088256
author Li, Teng
Xu, Qiong
Zhan, Xian-zhang
Xue, Yu-mei
Liao, Hong-tao
Li, Yi-fu
Letsas, Konstantinos P.
Wu, Shu-lin
author_facet Li, Teng
Xu, Qiong
Zhan, Xian-zhang
Xue, Yu-mei
Liao, Hong-tao
Li, Yi-fu
Letsas, Konstantinos P.
Wu, Shu-lin
author_sort Li, Teng
collection PubMed
description BACKGROUND: The ECG characteristics of the distal coronary venous system ventricular arrhythmias (VAs) share common features with VAs arising from the aortic cusps or the endocardial left ventricular outflow tract (LVOT) beneath the cusps. The purpose of this study was to identify specific electrocardiographic and electrophysiological characteristics of VAs originating from the distal great cardiac vein (GCV). METHODS: Based on the successful ablation site, patients with idiopathic VAs from the distal GCV, left coronary cusp (LCC) or the subvalvular left ventricular outflow tract (LVOT) area were included in the present study. RESULTS: The final population consisted of 39 patients (35 males, mean age 51 ± 23 years). All VAs displayed a right bundle branch block (RBBB) morphology with inferior axis. Among these patients, 15 were successfully ablated at the GCV, 15 at the LCC and 9 at the subvalvular region. A “w” pattern in lead I was present in 12 out of 15 (80%) VAs originating from the distal GCV compared to none of VAs arising from the other two sites (p < 0.01). VAs with a GCV origin exhibited more commonly increased intrinsicoid deflection time, higher maximum deflection index and wider QRS duration compared to LCC and subvalvular sites (p < 0.05). Acceptable pace mapping at the successful ablation site was achieved in 10 patients. After an average of 36 ± 24 months follow up, 14 (93.3%) patients were free from VAs recurrence. CONCLUSION: A “w” pattern in lead I may distinguish distal GCV VAs from VAs arising from the LCC or the subvalvular region. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12872-019-1064-9) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6466655
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64666552019-04-22 Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein Li, Teng Xu, Qiong Zhan, Xian-zhang Xue, Yu-mei Liao, Hong-tao Li, Yi-fu Letsas, Konstantinos P. Wu, Shu-lin BMC Cardiovasc Disord Research Article BACKGROUND: The ECG characteristics of the distal coronary venous system ventricular arrhythmias (VAs) share common features with VAs arising from the aortic cusps or the endocardial left ventricular outflow tract (LVOT) beneath the cusps. The purpose of this study was to identify specific electrocardiographic and electrophysiological characteristics of VAs originating from the distal great cardiac vein (GCV). METHODS: Based on the successful ablation site, patients with idiopathic VAs from the distal GCV, left coronary cusp (LCC) or the subvalvular left ventricular outflow tract (LVOT) area were included in the present study. RESULTS: The final population consisted of 39 patients (35 males, mean age 51 ± 23 years). All VAs displayed a right bundle branch block (RBBB) morphology with inferior axis. Among these patients, 15 were successfully ablated at the GCV, 15 at the LCC and 9 at the subvalvular region. A “w” pattern in lead I was present in 12 out of 15 (80%) VAs originating from the distal GCV compared to none of VAs arising from the other two sites (p < 0.01). VAs with a GCV origin exhibited more commonly increased intrinsicoid deflection time, higher maximum deflection index and wider QRS duration compared to LCC and subvalvular sites (p < 0.05). Acceptable pace mapping at the successful ablation site was achieved in 10 patients. After an average of 36 ± 24 months follow up, 14 (93.3%) patients were free from VAs recurrence. CONCLUSION: A “w” pattern in lead I may distinguish distal GCV VAs from VAs arising from the LCC or the subvalvular region. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12872-019-1064-9) contains supplementary material, which is available to authorized users. BioMed Central 2019-04-15 /pmc/articles/PMC6466655/ /pubmed/30987582 http://dx.doi.org/10.1186/s12872-019-1064-9 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Li, Teng
Xu, Qiong
Zhan, Xian-zhang
Xue, Yu-mei
Liao, Hong-tao
Li, Yi-fu
Letsas, Konstantinos P.
Wu, Shu-lin
Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title_full Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title_fullStr Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title_full_unstemmed Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title_short Unique electrocardiographic pattern “w” wave in lead I of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
title_sort unique electrocardiographic pattern “w” wave in lead i of idiopathic ventricular arrhythmias arising from the distal great cardiac vein
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6466655/
https://www.ncbi.nlm.nih.gov/pubmed/30987582
http://dx.doi.org/10.1186/s12872-019-1064-9
work_keys_str_mv AT liteng uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT xuqiong uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT zhanxianzhang uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT xueyumei uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT liaohongtao uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT liyifu uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT letsaskonstantinosp uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein
AT wushulin uniqueelectrocardiographicpatternwwaveinleadiofidiopathicventriculararrhythmiasarisingfromthedistalgreatcardiacvein