An Improved Sliding Window Area Method for T Wave Detection

BACKGROUND: The T wave represents ECG repolarization, whose detection is required during myocardial ischemia, and the first significant change in the ECG signal is being observed in the ST segment followed by changes in other waves like P wave and QRS complex. To offer guidance in clinical diagnosis...

Descripción completa

Detalles Bibliográficos
Autores principales: Shang, Haixia, Wei, Shoushui, Liu, Feifei, Wei, Dingwen, Chen, Lei, Liu, Chengyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6466942/
https://www.ncbi.nlm.nih.gov/pubmed/31065291
http://dx.doi.org/10.1155/2019/3130527
Descripción
Sumario:BACKGROUND: The T wave represents ECG repolarization, whose detection is required during myocardial ischemia, and the first significant change in the ECG signal is being observed in the ST segment followed by changes in other waves like P wave and QRS complex. To offer guidance in clinical diagnosis, decision-making, and daily mobile ECG monitoring, the T wave needs to be detected firstly. Recently, the sliding area-based method has received an increasing amount of attention due to its robustness and low computational burden. However, the parameter setting of the search window's boundaries in this method is not adaptive. Therefore, in this study, we proposed an improved sliding window area method with more adaptive parameter setting for T wave detection. METHODS: Firstly, k-means clustering was used in the annotated MIT QT database to generate three piecewise functions for delineating the relationship between the RR interval and the interval from the R peak to the T wave onset and that between the RR interval and the interval from the R peak to the T wave offset. Then, the grid search technique combined with 5-fold cross validation was used to select the suitable parameters' combination for the sliding window area method. RESULTS: With respect to onset detection in the QT database, F1 improved from 54.70% to 70.46% and 54.05% to 72.94% for the first and second electrocardiogram (ECG) channels, respectively. For offset detection, F1 also improved in both channels as it did in the European ST-T database. CONCLUSIONS: F1 results from the improved algorithm version were higher than those from the traditional method, indicating a potentially useful application for the proposed method in ECG monitoring.