Cargando…

Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation

PURPOSE: There is concern that some generic preference-based measures (GPMs) of health-related quality of life may be insensitive to interventions that improve hearing. Establishing where sensitivity arises could contribute to the design of improved measures. Accordingly, we compared the sensitivity...

Descripción completa

Detalles Bibliográficos
Autores principales: Summerfield, A. Q., Barton, G. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470108/
https://www.ncbi.nlm.nih.gov/pubmed/30484121
http://dx.doi.org/10.1007/s11136-018-2070-6
_version_ 1783411727032909824
author Summerfield, A. Q.
Barton, G. R.
author_facet Summerfield, A. Q.
Barton, G. R.
author_sort Summerfield, A. Q.
collection PubMed
description PURPOSE: There is concern that some generic preference-based measures (GPMs) of health-related quality of life may be insensitive to interventions that improve hearing. Establishing where sensitivity arises could contribute to the design of improved measures. Accordingly, we compared the sensitivity of four widely used GPMs to a clinically effective treatment—cochlear implantation—which restores material degrees of hearing to adults with little or no functional hearing. METHODS: Participants (N = 147) received implants in any of 13 hospitals in the UK. One month before implantation and 9 months after, they completed the HUI2, HUI3, EQ5D3L, and SF-6D questionnaires, together with the EuroQoL visual-analogue scale as a direct measure of health, a performance test of speech reception, and a self-report measure of annoyance due to tinnitus. RESULTS: Implantation was associated with a large improvement in speech reception and a small improvement in tinnitus. HUI2 and HUI3 were sensitive to the improvement in speech reception through their Sensation and Hearing dimensions; EQ5D3L was sensitive to the improvement in tinnitus through its Anxiety/Depression dimension; SF-6D was sensitive to neither. Participants reported no overall improvement in health. Variation in health was associated with variation in tinnitus, not variation in speech reception. CONCLUSIONS: None of the four GPMs was sensitive to the improvements in both speech reception and tinnitus that were associated with cochlear implantation. To capture fully the benefits of interventions for auditory disorders, developments of current GPMs would need to be sensitive to both the health-related and non-health-related aspects of auditory dysfunction. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11136-018-2070-6) contains supplementary material, which is available to authorised users.
format Online
Article
Text
id pubmed-6470108
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-64701082019-05-03 Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation Summerfield, A. Q. Barton, G. R. Qual Life Res Article PURPOSE: There is concern that some generic preference-based measures (GPMs) of health-related quality of life may be insensitive to interventions that improve hearing. Establishing where sensitivity arises could contribute to the design of improved measures. Accordingly, we compared the sensitivity of four widely used GPMs to a clinically effective treatment—cochlear implantation—which restores material degrees of hearing to adults with little or no functional hearing. METHODS: Participants (N = 147) received implants in any of 13 hospitals in the UK. One month before implantation and 9 months after, they completed the HUI2, HUI3, EQ5D3L, and SF-6D questionnaires, together with the EuroQoL visual-analogue scale as a direct measure of health, a performance test of speech reception, and a self-report measure of annoyance due to tinnitus. RESULTS: Implantation was associated with a large improvement in speech reception and a small improvement in tinnitus. HUI2 and HUI3 were sensitive to the improvement in speech reception through their Sensation and Hearing dimensions; EQ5D3L was sensitive to the improvement in tinnitus through its Anxiety/Depression dimension; SF-6D was sensitive to neither. Participants reported no overall improvement in health. Variation in health was associated with variation in tinnitus, not variation in speech reception. CONCLUSIONS: None of the four GPMs was sensitive to the improvements in both speech reception and tinnitus that were associated with cochlear implantation. To capture fully the benefits of interventions for auditory disorders, developments of current GPMs would need to be sensitive to both the health-related and non-health-related aspects of auditory dysfunction. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11136-018-2070-6) contains supplementary material, which is available to authorised users. Springer International Publishing 2018-11-27 2019 /pmc/articles/PMC6470108/ /pubmed/30484121 http://dx.doi.org/10.1007/s11136-018-2070-6 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Summerfield, A. Q.
Barton, G. R.
Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title_full Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title_fullStr Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title_full_unstemmed Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title_short Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
title_sort sensitivity of eq-5d-3l, hui2, hui3, and sf-6d to changes in speech reception and tinnitus associated with cochlear implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470108/
https://www.ncbi.nlm.nih.gov/pubmed/30484121
http://dx.doi.org/10.1007/s11136-018-2070-6
work_keys_str_mv AT summerfieldaq sensitivityofeq5d3lhui2hui3andsf6dtochangesinspeechreceptionandtinnitusassociatedwithcochlearimplantation
AT bartongr sensitivityofeq5d3lhui2hui3andsf6dtochangesinspeechreceptionandtinnitusassociatedwithcochlearimplantation
AT sensitivityofeq5d3lhui2hui3andsf6dtochangesinspeechreceptionandtinnitusassociatedwithcochlearimplantation