Cargando…

Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis

Objectives: Stresses produced during the fabrication of copings and by chewing activity can induce a tetragonal-to-monoclinic (t–m) transformation of zirconia. As a consequence, in the m-phase, the material is not able to hinder possible cracks by the favorable mechanism known as “transformation tou...

Descripción completa

Detalles Bibliográficos
Autores principales: Sorrentino, Roberto, Navarra, Chiara Ottavia, Di Lenarda, Roberto, Breschi, Lorenzo, Zarone, Fernando, Cadenaro, Milena, Spagnuolo, Gianrico
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470560/
https://www.ncbi.nlm.nih.gov/pubmed/30875849
http://dx.doi.org/10.3390/ma12060863
_version_ 1783411825525653504
author Sorrentino, Roberto
Navarra, Chiara Ottavia
Di Lenarda, Roberto
Breschi, Lorenzo
Zarone, Fernando
Cadenaro, Milena
Spagnuolo, Gianrico
author_facet Sorrentino, Roberto
Navarra, Chiara Ottavia
Di Lenarda, Roberto
Breschi, Lorenzo
Zarone, Fernando
Cadenaro, Milena
Spagnuolo, Gianrico
author_sort Sorrentino, Roberto
collection PubMed
description Objectives: Stresses produced during the fabrication of copings and by chewing activity can induce a tetragonal-to-monoclinic (t–m) transformation of zirconia. As a consequence, in the m-phase, the material is not able to hinder possible cracks by the favorable mechanism known as “transformation toughening”. This study aimed at evaluating if different marginal preparations of zirconia copings can cause a premature phase transformation immediately after manufacturing milling and after chewing simulation. Methods: Ninety copings using three commercial zirconia ceramics (Nobel Procera Zirconia, Nobel Biocare Management AG; Lava Classic, 3M ESPE; Lava Plus, 3M ESPE) were prepared with deep-chamfer, slight-chamfer, or feather-edge finish lines (n = 10). Specimens were tested in a chewing simulator (CS-4.4, SD Mechatronik) under cyclic occlusal loads simulating one year of clinical service. Raman spectra were acquired and analyzed for each specimen along the finish lines and at the top of each coping before and after chewing simulation, respectively. Results: Raman analysis did not show any t–m transformation both before and after chewing simulation, as the typical monoclinic bands at 181 cm(−1) and 192 cm(−1) were not detected in any of the tested specimens. Conclusions: After a one-year simulation of chewing activity, irrespective of preparation geometry, zirconia copings did not show any sign of t–m transformation, either in the load application areas or at the margins. Consequently, manufacturing milling even in thin thickness did not cause any structural modification of zirconia ceramics “as received by manufacturers” both before and after chewing simulation.
format Online
Article
Text
id pubmed-6470560
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64705602019-04-27 Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis Sorrentino, Roberto Navarra, Chiara Ottavia Di Lenarda, Roberto Breschi, Lorenzo Zarone, Fernando Cadenaro, Milena Spagnuolo, Gianrico Materials (Basel) Article Objectives: Stresses produced during the fabrication of copings and by chewing activity can induce a tetragonal-to-monoclinic (t–m) transformation of zirconia. As a consequence, in the m-phase, the material is not able to hinder possible cracks by the favorable mechanism known as “transformation toughening”. This study aimed at evaluating if different marginal preparations of zirconia copings can cause a premature phase transformation immediately after manufacturing milling and after chewing simulation. Methods: Ninety copings using three commercial zirconia ceramics (Nobel Procera Zirconia, Nobel Biocare Management AG; Lava Classic, 3M ESPE; Lava Plus, 3M ESPE) were prepared with deep-chamfer, slight-chamfer, or feather-edge finish lines (n = 10). Specimens were tested in a chewing simulator (CS-4.4, SD Mechatronik) under cyclic occlusal loads simulating one year of clinical service. Raman spectra were acquired and analyzed for each specimen along the finish lines and at the top of each coping before and after chewing simulation, respectively. Results: Raman analysis did not show any t–m transformation both before and after chewing simulation, as the typical monoclinic bands at 181 cm(−1) and 192 cm(−1) were not detected in any of the tested specimens. Conclusions: After a one-year simulation of chewing activity, irrespective of preparation geometry, zirconia copings did not show any sign of t–m transformation, either in the load application areas or at the margins. Consequently, manufacturing milling even in thin thickness did not cause any structural modification of zirconia ceramics “as received by manufacturers” both before and after chewing simulation. MDPI 2019-03-14 /pmc/articles/PMC6470560/ /pubmed/30875849 http://dx.doi.org/10.3390/ma12060863 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sorrentino, Roberto
Navarra, Chiara Ottavia
Di Lenarda, Roberto
Breschi, Lorenzo
Zarone, Fernando
Cadenaro, Milena
Spagnuolo, Gianrico
Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title_full Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title_fullStr Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title_full_unstemmed Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title_short Effects of Finish Line Design and Fatigue Cyclic Loading on Phase Transformation of Zirconia Dental Ceramics: A Qualitative Micro-Raman Spectroscopic Analysis
title_sort effects of finish line design and fatigue cyclic loading on phase transformation of zirconia dental ceramics: a qualitative micro-raman spectroscopic analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470560/
https://www.ncbi.nlm.nih.gov/pubmed/30875849
http://dx.doi.org/10.3390/ma12060863
work_keys_str_mv AT sorrentinoroberto effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT navarrachiaraottavia effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT dilenardaroberto effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT breschilorenzo effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT zaronefernando effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT cadenaromilena effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis
AT spagnuologianrico effectsoffinishlinedesignandfatiguecyclicloadingonphasetransformationofzirconiadentalceramicsaqualitativemicroramanspectroscopicanalysis