Cargando…

Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector

Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur a...

Descripción completa

Detalles Bibliográficos
Autores principales: Grochocki, Wojciech, Buszewska-Forajta, Magdalena, Macioszek, Szymon, J. Markuszewski, Michał
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470587/
https://www.ncbi.nlm.nih.gov/pubmed/30909656
http://dx.doi.org/10.3390/molecules24061166
_version_ 1783411831730077696
author Grochocki, Wojciech
Buszewska-Forajta, Magdalena
Macioszek, Szymon
J. Markuszewski, Michał
author_facet Grochocki, Wojciech
Buszewska-Forajta, Magdalena
Macioszek, Szymon
J. Markuszewski, Michał
author_sort Grochocki, Wojciech
collection PubMed
description Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur at shallow concentration levels, and thus, standard UV detectors cannot be used without additional sample preconcentration. On the other hand, ultra-sensitive laser-induced fluorescence (LIF) detection can be used since pterins exhibit native fluorescence. The main factor that limits an everyday use of LIF detectors is its high price. Here, an alternative detector, i.e., light-emitted diode induced fluorescence (LEDIF) detector, was evaluated for the determination of pterins in urine samples after capillary electrophoresis (CE) separation. An optimized method was validated in terms of linearity range, limit of detection (LOD), limit of quantification (LOQ), intra- and interday precision and accuracy, sample stability in the autosampler, and sample stability during the freezing/thawing cycle. The obtained LOD (0.1 µM) and LOQ (0.3 µM) values were three-order of magnitude lower compared to UV detector, and two orders of magnitude higher compared to previously reported house-built LIF detector. The applicability of the validated method was demonstrated in the analysis of urine samples from healthy individuals and cancer patients.
format Online
Article
Text
id pubmed-6470587
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64705872019-04-26 Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector Grochocki, Wojciech Buszewska-Forajta, Magdalena Macioszek, Szymon J. Markuszewski, Michał Molecules Article Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur at shallow concentration levels, and thus, standard UV detectors cannot be used without additional sample preconcentration. On the other hand, ultra-sensitive laser-induced fluorescence (LIF) detection can be used since pterins exhibit native fluorescence. The main factor that limits an everyday use of LIF detectors is its high price. Here, an alternative detector, i.e., light-emitted diode induced fluorescence (LEDIF) detector, was evaluated for the determination of pterins in urine samples after capillary electrophoresis (CE) separation. An optimized method was validated in terms of linearity range, limit of detection (LOD), limit of quantification (LOQ), intra- and interday precision and accuracy, sample stability in the autosampler, and sample stability during the freezing/thawing cycle. The obtained LOD (0.1 µM) and LOQ (0.3 µM) values were three-order of magnitude lower compared to UV detector, and two orders of magnitude higher compared to previously reported house-built LIF detector. The applicability of the validated method was demonstrated in the analysis of urine samples from healthy individuals and cancer patients. MDPI 2019-03-24 /pmc/articles/PMC6470587/ /pubmed/30909656 http://dx.doi.org/10.3390/molecules24061166 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Grochocki, Wojciech
Buszewska-Forajta, Magdalena
Macioszek, Szymon
J. Markuszewski, Michał
Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title_full Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title_fullStr Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title_full_unstemmed Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title_short Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
title_sort determination of urinary pterins by capillary electrophoresis coupled with led-induced fluorescence detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6470587/
https://www.ncbi.nlm.nih.gov/pubmed/30909656
http://dx.doi.org/10.3390/molecules24061166
work_keys_str_mv AT grochockiwojciech determinationofurinarypterinsbycapillaryelectrophoresiscoupledwithledinducedfluorescencedetector
AT buszewskaforajtamagdalena determinationofurinarypterinsbycapillaryelectrophoresiscoupledwithledinducedfluorescencedetector
AT macioszekszymon determinationofurinarypterinsbycapillaryelectrophoresiscoupledwithledinducedfluorescencedetector
AT jmarkuszewskimichał determinationofurinarypterinsbycapillaryelectrophoresiscoupledwithledinducedfluorescencedetector