In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor

Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhuofu, Li, Jianwei, Liu, Meimei, Cascioli, Vincenzo, McCarthy, Peter W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471173/
https://www.ncbi.nlm.nih.gov/pubmed/30917555
http://dx.doi.org/10.3390/s19061471
_version_ 1783411967910739968
author Liu, Zhuofu
Li, Jianwei
Liu, Meimei
Cascioli, Vincenzo
McCarthy, Peter W
author_facet Liu, Zhuofu
Li, Jianwei
Liu, Meimei
Cascioli, Vincenzo
McCarthy, Peter W
author_sort Liu, Zhuofu
collection PubMed
description Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes at the body-seat interface; using RH sensors without the capability to record temperature where RH is recorded. To explore the causes of a spike in RH consistently produced on first contact between body and seat surface, we report data from the first use of dual temperature and RH (HTU21D) sensors in this interface. Following evaluation of sensor performance, the effect of local thermal changes on RH was investigated. The expected strong negative correlation between temperature and RH (R(2) = −0.94) supported the importance of considering both parameters when studying impact of sitting on skin health. The influence of sensor movement speed (higher velocity approach: 0.32 cm/s ± 0.01 cm/s; lower velocity approach: 0.17 cm/s ± 0.01 cm/s) into a static RH region associated with a higher local temperature were compared with data gathered by altering the rate of a person sitting. In all cases, the faster sitting down (or equivalent) generated larger RH outcomes: e.g., in human sitting 53.7% ± 3.3% RH (left mid-thigh), 56.4% ± 5.1% RH (right mid-thigh) and 53.2% ± 2.7% RH (Coccyx). Differences in size of RH change were seen across the measurement locations used to study the body-seat interface. The initial sitting contact induces a transient RH response (duration ≤ 40 s) that does not accurately reflect the microenvironment at the body-seat interface. It is likely that any movement during sitting would result in similar artefact formation. As a result, caution should be taken when investigating RH performance at any enclosed interface when the surfaces may have different temperatures and movement may occur.
format Online
Article
Text
id pubmed-6471173
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64711732019-04-26 In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor Liu, Zhuofu Li, Jianwei Liu, Meimei Cascioli, Vincenzo McCarthy, Peter W Sensors (Basel) Article Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes at the body-seat interface; using RH sensors without the capability to record temperature where RH is recorded. To explore the causes of a spike in RH consistently produced on first contact between body and seat surface, we report data from the first use of dual temperature and RH (HTU21D) sensors in this interface. Following evaluation of sensor performance, the effect of local thermal changes on RH was investigated. The expected strong negative correlation between temperature and RH (R(2) = −0.94) supported the importance of considering both parameters when studying impact of sitting on skin health. The influence of sensor movement speed (higher velocity approach: 0.32 cm/s ± 0.01 cm/s; lower velocity approach: 0.17 cm/s ± 0.01 cm/s) into a static RH region associated with a higher local temperature were compared with data gathered by altering the rate of a person sitting. In all cases, the faster sitting down (or equivalent) generated larger RH outcomes: e.g., in human sitting 53.7% ± 3.3% RH (left mid-thigh), 56.4% ± 5.1% RH (right mid-thigh) and 53.2% ± 2.7% RH (Coccyx). Differences in size of RH change were seen across the measurement locations used to study the body-seat interface. The initial sitting contact induces a transient RH response (duration ≤ 40 s) that does not accurately reflect the microenvironment at the body-seat interface. It is likely that any movement during sitting would result in similar artefact formation. As a result, caution should be taken when investigating RH performance at any enclosed interface when the surfaces may have different temperatures and movement may occur. MDPI 2019-03-26 /pmc/articles/PMC6471173/ /pubmed/30917555 http://dx.doi.org/10.3390/s19061471 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Zhuofu
Li, Jianwei
Liu, Meimei
Cascioli, Vincenzo
McCarthy, Peter W
In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title_full In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title_fullStr In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title_full_unstemmed In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title_short In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
title_sort in-depth investigation into the transient humidity response at the body-seat interface on initial contact using a dual temperature and humidity sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471173/
https://www.ncbi.nlm.nih.gov/pubmed/30917555
http://dx.doi.org/10.3390/s19061471
work_keys_str_mv AT liuzhuofu indepthinvestigationintothetransienthumidityresponseatthebodyseatinterfaceoninitialcontactusingadualtemperatureandhumiditysensor
AT lijianwei indepthinvestigationintothetransienthumidityresponseatthebodyseatinterfaceoninitialcontactusingadualtemperatureandhumiditysensor
AT liumeimei indepthinvestigationintothetransienthumidityresponseatthebodyseatinterfaceoninitialcontactusingadualtemperatureandhumiditysensor
AT casciolivincenzo indepthinvestigationintothetransienthumidityresponseatthebodyseatinterfaceoninitialcontactusingadualtemperatureandhumiditysensor
AT mccarthypeterw indepthinvestigationintothetransienthumidityresponseatthebodyseatinterfaceoninitialcontactusingadualtemperatureandhumiditysensor