Cargando…

In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors

This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sens...

Descripción completa

Detalles Bibliográficos
Autores principales: Philippe, Julien, De Paolis, Maria Valeria, Henry, Dominique, Rumeau, Alexandre, Coustou, Antony, Pons, Patrick, Aubert, Hervé
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471530/
https://www.ncbi.nlm.nih.gov/pubmed/30871142
http://dx.doi.org/10.3390/s19061263
_version_ 1783412048773775360
author Philippe, Julien
De Paolis, Maria Valeria
Henry, Dominique
Rumeau, Alexandre
Coustou, Antony
Pons, Patrick
Aubert, Hervé
author_facet Philippe, Julien
De Paolis, Maria Valeria
Henry, Dominique
Rumeau, Alexandre
Coustou, Antony
Pons, Patrick
Aubert, Hervé
author_sort Philippe, Julien
collection PubMed
description This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments.
format Online
Article
Text
id pubmed-6471530
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64715302019-04-26 In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors Philippe, Julien De Paolis, Maria Valeria Henry, Dominique Rumeau, Alexandre Coustou, Antony Pons, Patrick Aubert, Hervé Sensors (Basel) Article This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments. MDPI 2019-03-13 /pmc/articles/PMC6471530/ /pubmed/30871142 http://dx.doi.org/10.3390/s19061263 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Philippe, Julien
De Paolis, Maria Valeria
Henry, Dominique
Rumeau, Alexandre
Coustou, Antony
Pons, Patrick
Aubert, Hervé
In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title_full In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title_fullStr In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title_full_unstemmed In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title_short In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
title_sort in-situ wireless pressure measurement using zero-power packaged microwave sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471530/
https://www.ncbi.nlm.nih.gov/pubmed/30871142
http://dx.doi.org/10.3390/s19061263
work_keys_str_mv AT philippejulien insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT depaolismariavaleria insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT henrydominique insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT rumeaualexandre insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT coustouantony insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT ponspatrick insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors
AT aubertherve insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors