Cargando…
In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors
This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sens...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471530/ https://www.ncbi.nlm.nih.gov/pubmed/30871142 http://dx.doi.org/10.3390/s19061263 |
_version_ | 1783412048773775360 |
---|---|
author | Philippe, Julien De Paolis, Maria Valeria Henry, Dominique Rumeau, Alexandre Coustou, Antony Pons, Patrick Aubert, Hervé |
author_facet | Philippe, Julien De Paolis, Maria Valeria Henry, Dominique Rumeau, Alexandre Coustou, Antony Pons, Patrick Aubert, Hervé |
author_sort | Philippe, Julien |
collection | PubMed |
description | This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments. |
format | Online Article Text |
id | pubmed-6471530 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64715302019-04-26 In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors Philippe, Julien De Paolis, Maria Valeria Henry, Dominique Rumeau, Alexandre Coustou, Antony Pons, Patrick Aubert, Hervé Sensors (Basel) Article This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments. MDPI 2019-03-13 /pmc/articles/PMC6471530/ /pubmed/30871142 http://dx.doi.org/10.3390/s19061263 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Philippe, Julien De Paolis, Maria Valeria Henry, Dominique Rumeau, Alexandre Coustou, Antony Pons, Patrick Aubert, Hervé In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title | In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title_full | In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title_fullStr | In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title_full_unstemmed | In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title_short | In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors |
title_sort | in-situ wireless pressure measurement using zero-power packaged microwave sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6471530/ https://www.ncbi.nlm.nih.gov/pubmed/30871142 http://dx.doi.org/10.3390/s19061263 |
work_keys_str_mv | AT philippejulien insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT depaolismariavaleria insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT henrydominique insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT rumeaualexandre insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT coustouantony insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT ponspatrick insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors AT aubertherve insituwirelesspressuremeasurementusingzeropowerpackagedmicrowavesensors |