Gait Training Using the Honda Walking Assistive Device(®) in a Patient Who Underwent Total Hip Arthroplasty: A Single-Subject Study
Background and objectives: The Honda Walking Assistive device(®) (HWA) is a light and easy wearable robot device for gait training, which assists patients’ hip flexion and extension movements to guide hip joint movements during gait. However, the safety and feasibility of robot-assisted gait trainin...
Autores principales: | Koseki, Kazunori, Mutsuzaki, Hirotaka, Yoshikawa, Kenichi, Endo, Yusuke, Maezawa, Takayuki, Takano, Hanako, Yozu, Arito, Kohno, Yutaka |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6473675/ https://www.ncbi.nlm.nih.gov/pubmed/30875846 http://dx.doi.org/10.3390/medicina55030069 |
Ejemplares similares
-
Gait training using the Honda Walking Assist Device [Formula: see text] for individuals with transfemoral amputation: A report of two cases
por: Koseki, Kazunori, et al.
Publicado: (2020) -
Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report
por: Yoshikawa, Kenichi, et al.
Publicado: (2020) -
Adjusting Assistance Commensurates with Patient Effort During Robot-Assisted Upper Limb Training for a Patient with Spasticity After Cervical Spinal Cord Injury: A Case Report
por: Yoshikawa, Kenichi, et al.
Publicado: (2019) -
Gait Training Using a Hip-Wearable Robotic Exoskeleton After Total
Knee Arthroplasty: A Case Report
por: Koseki, Kazunori, et al.
Publicado: (2020) -
Long-term sustained effect of gait training using a hybrid assistive limb on
gait stability via prevention of knee collapse in a patient with cerebral palsy: a case
report
por: Endo, Yusuke, et al.