Cargando…

Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode

4-nitrophenol (4-NP) is a hazardous waste and a priority toxic pollutant identified by US Environmental Protection Agency (EPA). Hence, in this paper, a voltammetric sensor was proposed for the direct and sensitive detection of 4-nitrophenol (4-NP) at nanomolar level in complex matrices by using gra...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Quanguo, Tian, Yaling, Wu, Yiyong, Liu, Jun, Li, Guangli, Deng, Peihong, Chen, Dongchu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6473960/
https://www.ncbi.nlm.nih.gov/pubmed/30871263
http://dx.doi.org/10.3390/nano9030429
_version_ 1783412545635221504
author He, Quanguo
Tian, Yaling
Wu, Yiyong
Liu, Jun
Li, Guangli
Deng, Peihong
Chen, Dongchu
author_facet He, Quanguo
Tian, Yaling
Wu, Yiyong
Liu, Jun
Li, Guangli
Deng, Peihong
Chen, Dongchu
author_sort He, Quanguo
collection PubMed
description 4-nitrophenol (4-NP) is a hazardous waste and a priority toxic pollutant identified by US Environmental Protection Agency (EPA). Hence, in this paper, a voltammetric sensor was proposed for the direct and sensitive detection of 4-nitrophenol (4-NP) at nanomolar level in complex matrices by using graphene and acetylene black paste hybridized electrode (GR/ABPE). Under optimal conditions, the calibration curve demonstrates a linear relationship for 4-NP in the range from 20 nM to 8.0 μM and 8.0 μM to 0.1 mM separately with the detection limit of 8.0 nM. In addition to it, the performance of the GR/ABPE in practical applications was evaluated by detecting 4-NP in various water samples, and satisfactory recoveries were realized. Therefore, GR/ABPE may have a great potential application for facile and sensitive detection of 4-NP in complex matrices at nanomolar level.
format Online
Article
Text
id pubmed-6473960
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64739602019-05-03 Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode He, Quanguo Tian, Yaling Wu, Yiyong Liu, Jun Li, Guangli Deng, Peihong Chen, Dongchu Nanomaterials (Basel) Article 4-nitrophenol (4-NP) is a hazardous waste and a priority toxic pollutant identified by US Environmental Protection Agency (EPA). Hence, in this paper, a voltammetric sensor was proposed for the direct and sensitive detection of 4-nitrophenol (4-NP) at nanomolar level in complex matrices by using graphene and acetylene black paste hybridized electrode (GR/ABPE). Under optimal conditions, the calibration curve demonstrates a linear relationship for 4-NP in the range from 20 nM to 8.0 μM and 8.0 μM to 0.1 mM separately with the detection limit of 8.0 nM. In addition to it, the performance of the GR/ABPE in practical applications was evaluated by detecting 4-NP in various water samples, and satisfactory recoveries were realized. Therefore, GR/ABPE may have a great potential application for facile and sensitive detection of 4-NP in complex matrices at nanomolar level. MDPI 2019-03-13 /pmc/articles/PMC6473960/ /pubmed/30871263 http://dx.doi.org/10.3390/nano9030429 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
He, Quanguo
Tian, Yaling
Wu, Yiyong
Liu, Jun
Li, Guangli
Deng, Peihong
Chen, Dongchu
Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title_full Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title_fullStr Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title_full_unstemmed Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title_short Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode
title_sort facile and ultrasensitive determination of 4-nitrophenol based on acetylene black paste and graphene hybrid electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6473960/
https://www.ncbi.nlm.nih.gov/pubmed/30871263
http://dx.doi.org/10.3390/nano9030429
work_keys_str_mv AT hequanguo facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT tianyaling facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT wuyiyong facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT liujun facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT liguangli facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT dengpeihong facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode
AT chendongchu facileandultrasensitivedeterminationof4nitrophenolbasedonacetyleneblackpasteandgraphenehybridelectrode