An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing
OBJECTIVE: The use of personal cooling systems to mitigate heat strain on first-responders achieves two potential performance benefits relative to the absence of such cooling: (1) the completion of a workload with less effort; and/or (2) the completion of a greater workload for the same effort. Curr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6474400/ https://www.ncbi.nlm.nih.gov/pubmed/31031643 http://dx.doi.org/10.3389/fphys.2019.00424 |
_version_ | 1783412626812829696 |
---|---|
author | Bach, Aaron J. E. Maley, Matthew J. Minett, Geoffrey M. Zietek, Stephanie A. Stewart, Kelly L. Stewart, Ian B. |
author_facet | Bach, Aaron J. E. Maley, Matthew J. Minett, Geoffrey M. Zietek, Stephanie A. Stewart, Kelly L. Stewart, Ian B. |
author_sort | Bach, Aaron J. E. |
collection | PubMed |
description | OBJECTIVE: The use of personal cooling systems to mitigate heat strain on first-responders achieves two potential performance benefits relative to the absence of such cooling: (1) the completion of a workload with less effort; and/or (2) the completion of a greater workload for the same effort. Currently, claims made by manufacturers regarding the capability of their products for use in conjunction with chemical/biological protective clothing remain largely unsubstantiated. The purpose of this investigation was to evaluate the means by which heat strain can be alleviated during uncompensable heat stress in chemical/biological clothing, using the ASTM F2300-10 methodology. METHODS: Eight healthy males completed five trials of continuous walking (4.5 km h(−1); 35°C; 49% RH) for up to 120 min while wearing one of four cooling systems and/or a National Fire and Protection Association 1994 Class-3 chemical/biological ensemble. The four cooling methods (ice vest [IV], phase-change vest [PCM], water-perfused suit [WS], and combination ice slurry/ice vest [SLIV]) and no cooling (CON). RESULTS: We observed significant improvements in trial times for IV (18 ± 10 min), PCM (20 ± 10 min) and SLIV (22 ± 10 min), but no differences for WS (4 ± 7 min). Heart rate, rectal, mean skin, and body temperatures were significantly lower in all cooling conditions relative to control at various matched time points in the first 60 min of exercise. Thermal sensation, comfort and perceived exertion all had significant main effects for condition, and time, there were no differences in their respective interactions. CONCLUSION: The IV, PCM, and SLIV produced lower heart rate, mean skin, rectal and mean body temperatures in addition to improved work times compared to control. The WS did not improve work times possibly as a result of the cooling capacity of the suit abating, and magnifying thermal insulation. Considering the added time and resources required to implement combination cooling in the form of ice slurry and ice vest (SLIV), there was no significant additive effect for perception, cardiovascular strain, rectal temperature and total trial time relative to the phase change vest or ice vest alone. This may be a product of a “ceiling” effect for work limit set to 120 min as part of ASTM F2300-10. |
format | Online Article Text |
id | pubmed-6474400 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64744002019-04-26 An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing Bach, Aaron J. E. Maley, Matthew J. Minett, Geoffrey M. Zietek, Stephanie A. Stewart, Kelly L. Stewart, Ian B. Front Physiol Physiology OBJECTIVE: The use of personal cooling systems to mitigate heat strain on first-responders achieves two potential performance benefits relative to the absence of such cooling: (1) the completion of a workload with less effort; and/or (2) the completion of a greater workload for the same effort. Currently, claims made by manufacturers regarding the capability of their products for use in conjunction with chemical/biological protective clothing remain largely unsubstantiated. The purpose of this investigation was to evaluate the means by which heat strain can be alleviated during uncompensable heat stress in chemical/biological clothing, using the ASTM F2300-10 methodology. METHODS: Eight healthy males completed five trials of continuous walking (4.5 km h(−1); 35°C; 49% RH) for up to 120 min while wearing one of four cooling systems and/or a National Fire and Protection Association 1994 Class-3 chemical/biological ensemble. The four cooling methods (ice vest [IV], phase-change vest [PCM], water-perfused suit [WS], and combination ice slurry/ice vest [SLIV]) and no cooling (CON). RESULTS: We observed significant improvements in trial times for IV (18 ± 10 min), PCM (20 ± 10 min) and SLIV (22 ± 10 min), but no differences for WS (4 ± 7 min). Heart rate, rectal, mean skin, and body temperatures were significantly lower in all cooling conditions relative to control at various matched time points in the first 60 min of exercise. Thermal sensation, comfort and perceived exertion all had significant main effects for condition, and time, there were no differences in their respective interactions. CONCLUSION: The IV, PCM, and SLIV produced lower heart rate, mean skin, rectal and mean body temperatures in addition to improved work times compared to control. The WS did not improve work times possibly as a result of the cooling capacity of the suit abating, and magnifying thermal insulation. Considering the added time and resources required to implement combination cooling in the form of ice slurry and ice vest (SLIV), there was no significant additive effect for perception, cardiovascular strain, rectal temperature and total trial time relative to the phase change vest or ice vest alone. This may be a product of a “ceiling” effect for work limit set to 120 min as part of ASTM F2300-10. Frontiers Media S.A. 2019-04-12 /pmc/articles/PMC6474400/ /pubmed/31031643 http://dx.doi.org/10.3389/fphys.2019.00424 Text en Copyright © 2019 Bach, Maley, Minett, Zietek, Stewart and Stewart. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Bach, Aaron J. E. Maley, Matthew J. Minett, Geoffrey M. Zietek, Stephanie A. Stewart, Kelly L. Stewart, Ian B. An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title | An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title_full | An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title_fullStr | An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title_full_unstemmed | An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title_short | An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing |
title_sort | evaluation of personal cooling systems for reducing thermal strain whilst working in chemical/biological protective clothing |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6474400/ https://www.ncbi.nlm.nih.gov/pubmed/31031643 http://dx.doi.org/10.3389/fphys.2019.00424 |
work_keys_str_mv | AT bachaaronje anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT maleymatthewj anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT minettgeoffreym anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT zietekstephaniea anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT stewartkellyl anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT stewartianb anevaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT bachaaronje evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT maleymatthewj evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT minettgeoffreym evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT zietekstephaniea evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT stewartkellyl evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing AT stewartianb evaluationofpersonalcoolingsystemsforreducingthermalstrainwhilstworkinginchemicalbiologicalprotectiveclothing |