Cargando…

Young and middle‐aged mouse breathing behavior during the light and dark cycles

Unrestrained barometric plethysmography is a common method used for characterizing breathing patterns in small animals. One source of variation between unrestrained barometric plethysmography studies is the segment of baseline. Baseline may be analyzed as a predetermined time‐point, or using tailore...

Descripción completa

Detalles Bibliográficos
Autores principales: Receno, Candace N., Eassa, Brianna E., Cunningham, Caitlin M., DeRuisseau, Lara R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6474843/
https://www.ncbi.nlm.nih.gov/pubmed/31004390
http://dx.doi.org/10.14814/phy2.14060
_version_ 1783412666121846784
author Receno, Candace N.
Eassa, Brianna E.
Cunningham, Caitlin M.
DeRuisseau, Lara R.
author_facet Receno, Candace N.
Eassa, Brianna E.
Cunningham, Caitlin M.
DeRuisseau, Lara R.
author_sort Receno, Candace N.
collection PubMed
description Unrestrained barometric plethysmography is a common method used for characterizing breathing patterns in small animals. One source of variation between unrestrained barometric plethysmography studies is the segment of baseline. Baseline may be analyzed as a predetermined time‐point, or using tailored segments when each animal is visually calm. We compared a quiet, minimally active (no sniffing/grooming) breathing segment to a predetermined time‐point at 1 h for baseline measurements in young and middle‐aged mice during the dark and light cycles. Additionally, we evaluated the magnitude of change for gas challenges based on these two baseline segments. C57BL/6JEiJ x C3Sn.BliA‐Pde6b (+)/DnJ male mice underwent unrestrained barometric plethysmography with the following baselines used to determine breathing frequency, tidal volume (VT) and minute ventilation (VE): (1) 30‐sec of quiet breathing and (2) a 10‐min period from 50 to 60 min. Animals were also exposed to 10 min of hypoxic (10% O(2), balanced N(2)), hypercapnic (5% CO (2), balanced air) and hypoxic hypercapnic (10% O(2), 5% CO (2), balanced N(2)) gas. Both frequency and VE were higher during the predetermined 10‐min baseline versus the 30‐sec baseline, while VT was lower (P < 0.05). However, VE/V(O) (2) was similar between the baseline time segments (P > 0.05) in an analysis of one cohort. During baseline, dark cycle testing had increased VT values versus those in the light (P < 0.05). For gas challenges, both frequency and VE showed higher percent change from the 30‐sec baseline compared to the predetermined 10‐min baseline (P < 0.05), while VT showed a greater change from the 10‐min baseline (P < 0.05). Dark cycle hypoxic exposure resulted in larger percent change in breathing frequency versus the light cycle (P < 0.05). Overall, light and dark cycle pattern of breathing differences emerged along with differences between the 30‐sec behavior observational method versus a predetermined time segment for baseline.
format Online
Article
Text
id pubmed-6474843
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64748432019-04-24 Young and middle‐aged mouse breathing behavior during the light and dark cycles Receno, Candace N. Eassa, Brianna E. Cunningham, Caitlin M. DeRuisseau, Lara R. Physiol Rep Original Research Unrestrained barometric plethysmography is a common method used for characterizing breathing patterns in small animals. One source of variation between unrestrained barometric plethysmography studies is the segment of baseline. Baseline may be analyzed as a predetermined time‐point, or using tailored segments when each animal is visually calm. We compared a quiet, minimally active (no sniffing/grooming) breathing segment to a predetermined time‐point at 1 h for baseline measurements in young and middle‐aged mice during the dark and light cycles. Additionally, we evaluated the magnitude of change for gas challenges based on these two baseline segments. C57BL/6JEiJ x C3Sn.BliA‐Pde6b (+)/DnJ male mice underwent unrestrained barometric plethysmography with the following baselines used to determine breathing frequency, tidal volume (VT) and minute ventilation (VE): (1) 30‐sec of quiet breathing and (2) a 10‐min period from 50 to 60 min. Animals were also exposed to 10 min of hypoxic (10% O(2), balanced N(2)), hypercapnic (5% CO (2), balanced air) and hypoxic hypercapnic (10% O(2), 5% CO (2), balanced N(2)) gas. Both frequency and VE were higher during the predetermined 10‐min baseline versus the 30‐sec baseline, while VT was lower (P < 0.05). However, VE/V(O) (2) was similar between the baseline time segments (P > 0.05) in an analysis of one cohort. During baseline, dark cycle testing had increased VT values versus those in the light (P < 0.05). For gas challenges, both frequency and VE showed higher percent change from the 30‐sec baseline compared to the predetermined 10‐min baseline (P < 0.05), while VT showed a greater change from the 10‐min baseline (P < 0.05). Dark cycle hypoxic exposure resulted in larger percent change in breathing frequency versus the light cycle (P < 0.05). Overall, light and dark cycle pattern of breathing differences emerged along with differences between the 30‐sec behavior observational method versus a predetermined time segment for baseline. John Wiley and Sons Inc. 2019-04-19 /pmc/articles/PMC6474843/ /pubmed/31004390 http://dx.doi.org/10.14814/phy2.14060 Text en © 2019 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Receno, Candace N.
Eassa, Brianna E.
Cunningham, Caitlin M.
DeRuisseau, Lara R.
Young and middle‐aged mouse breathing behavior during the light and dark cycles
title Young and middle‐aged mouse breathing behavior during the light and dark cycles
title_full Young and middle‐aged mouse breathing behavior during the light and dark cycles
title_fullStr Young and middle‐aged mouse breathing behavior during the light and dark cycles
title_full_unstemmed Young and middle‐aged mouse breathing behavior during the light and dark cycles
title_short Young and middle‐aged mouse breathing behavior during the light and dark cycles
title_sort young and middle‐aged mouse breathing behavior during the light and dark cycles
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6474843/
https://www.ncbi.nlm.nih.gov/pubmed/31004390
http://dx.doi.org/10.14814/phy2.14060
work_keys_str_mv AT recenocandacen youngandmiddleagedmousebreathingbehaviorduringthelightanddarkcycles
AT eassabriannae youngandmiddleagedmousebreathingbehaviorduringthelightanddarkcycles
AT cunninghamcaitlinm youngandmiddleagedmousebreathingbehaviorduringthelightanddarkcycles
AT deruisseaularar youngandmiddleagedmousebreathingbehaviorduringthelightanddarkcycles