Cargando…

Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer

Cervical cancer is a life-threatening complication, appearing as the uncontrolled growth of abnormal cells in the lining of the cervix. Every year, increasing numbers of cervical cancer cases are reported worldwide. Different identification strategies were proposed to detect cervical cancer at the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hongqing, Lakshmipriya, Thangavel, Chen, Yeng, Gopinath, Subash C. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6475575/
https://www.ncbi.nlm.nih.gov/pubmed/31080815
http://dx.doi.org/10.1155/2019/2807123
_version_ 1783412773359714304
author Wang, Hongqing
Lakshmipriya, Thangavel
Chen, Yeng
Gopinath, Subash C. B.
author_facet Wang, Hongqing
Lakshmipriya, Thangavel
Chen, Yeng
Gopinath, Subash C. B.
author_sort Wang, Hongqing
collection PubMed
description Cervical cancer is a life-threatening complication, appearing as the uncontrolled growth of abnormal cells in the lining of the cervix. Every year, increasing numbers of cervical cancer cases are reported worldwide. Different identification strategies were proposed to detect cervical cancer at the earlier stages using various biomarkers. Squamous cell carcinoma antigen (SCC-Ag) is one of the potential biomarkers for this diagnosis. Nanomaterial-based detection systems were shown to be efficient with different clinical biomarkers. In this study, we have demonstrated strontium oxide-modified interdigitated electrode (IDE) fabrication by the sol-gel method and characterized by scanning electron microscopy and high-power microscopy. Analysis of the bare devices indicated the reproducibility with the fabrication, and further pH scouting on the device revealed that the reliability of the working pH ranges from 3 to 9. The sensing surface was tested to detect SCC-Ag against its specific antibody; the detection limit was found to be 10 pM, and the sensitivity was in the range between 1 and 10 pM as calculated by 3σ. The specificity experiment was carried out using major proteins from human serum, such as albumin and globulin. SCC-Ag was shown to be selectively detected on the strontium oxide-modified IDE surface.
format Online
Article
Text
id pubmed-6475575
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-64755752019-05-12 Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer Wang, Hongqing Lakshmipriya, Thangavel Chen, Yeng Gopinath, Subash C. B. Biomed Res Int Research Article Cervical cancer is a life-threatening complication, appearing as the uncontrolled growth of abnormal cells in the lining of the cervix. Every year, increasing numbers of cervical cancer cases are reported worldwide. Different identification strategies were proposed to detect cervical cancer at the earlier stages using various biomarkers. Squamous cell carcinoma antigen (SCC-Ag) is one of the potential biomarkers for this diagnosis. Nanomaterial-based detection systems were shown to be efficient with different clinical biomarkers. In this study, we have demonstrated strontium oxide-modified interdigitated electrode (IDE) fabrication by the sol-gel method and characterized by scanning electron microscopy and high-power microscopy. Analysis of the bare devices indicated the reproducibility with the fabrication, and further pH scouting on the device revealed that the reliability of the working pH ranges from 3 to 9. The sensing surface was tested to detect SCC-Ag against its specific antibody; the detection limit was found to be 10 pM, and the sensitivity was in the range between 1 and 10 pM as calculated by 3σ. The specificity experiment was carried out using major proteins from human serum, such as albumin and globulin. SCC-Ag was shown to be selectively detected on the strontium oxide-modified IDE surface. Hindawi 2019-04-07 /pmc/articles/PMC6475575/ /pubmed/31080815 http://dx.doi.org/10.1155/2019/2807123 Text en Copyright © 2019 Hongqing Wang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wang, Hongqing
Lakshmipriya, Thangavel
Chen, Yeng
Gopinath, Subash C. B.
Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title_full Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title_fullStr Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title_full_unstemmed Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title_short Squamous Cell Carcinoma Biomarker Sensing on a Strontium Oxide-Modified Interdigitated Electrode Surface for the Diagnosis of Cervical Cancer
title_sort squamous cell carcinoma biomarker sensing on a strontium oxide-modified interdigitated electrode surface for the diagnosis of cervical cancer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6475575/
https://www.ncbi.nlm.nih.gov/pubmed/31080815
http://dx.doi.org/10.1155/2019/2807123
work_keys_str_mv AT wanghongqing squamouscellcarcinomabiomarkersensingonastrontiumoxidemodifiedinterdigitatedelectrodesurfaceforthediagnosisofcervicalcancer
AT lakshmipriyathangavel squamouscellcarcinomabiomarkersensingonastrontiumoxidemodifiedinterdigitatedelectrodesurfaceforthediagnosisofcervicalcancer
AT chenyeng squamouscellcarcinomabiomarkersensingonastrontiumoxidemodifiedinterdigitatedelectrodesurfaceforthediagnosisofcervicalcancer
AT gopinathsubashcb squamouscellcarcinomabiomarkersensingonastrontiumoxidemodifiedinterdigitatedelectrodesurfaceforthediagnosisofcervicalcancer