Cargando…

Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures

Pain management in trauma patients with acute rib and spine fractures presents a challenge for the anesthesiologist and achieving adequate analgesia is important in preventing pulmonary complications. Unfortunately, neuraxial techniques are often challenging or contraindicated due to spine fractures...

Descripción completa

Detalles Bibliográficos
Autores principales: Klesius, L., Schroeder, K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6476142/
https://www.ncbi.nlm.nih.gov/pubmed/31093377
http://dx.doi.org/10.1155/2019/9159878
_version_ 1783412855776739328
author Klesius, L.
Schroeder, K.
author_facet Klesius, L.
Schroeder, K.
author_sort Klesius, L.
collection PubMed
description Pain management in trauma patients with acute rib and spine fractures presents a challenge for the anesthesiologist and achieving adequate analgesia is important in preventing pulmonary complications. Unfortunately, neuraxial techniques are often challenging or contraindicated due to spine fractures or coagulopathy. Erector spinae plane (ESP) blocks provide an alternative regional anesthetic technique to manage pain. We describe a case of bilateral ESP catheters placed intraoperatively after spinal instrumentation in a patient with bilateral rib and spine fractures sustained in a tractor rollover crash. Prior to surgery, the patient had inadequate pain control and poor respiratory function despite multimodal analgesia. With the addition of bilateral ESP catheters, the patient's pain control improved and he was weaned from respiratory support. ESP blocks have been shown to provide effective analgesia in patients with rib fractures; however, the utilization of these blocks has not been described in patients with spine fractures undergoing spinal instrumentation. Thus, ESP blocks provide a simple alternative to providing surgical and trauma analgesia when neuraxial techniques are contraindicated. The success of bilateral ESP catheters in our patient indicates a further area for application of ESP blocks in patients undergoing spine surgery with acute traumatic spine fractures.
format Online
Article
Text
id pubmed-6476142
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-64761422019-05-15 Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures Klesius, L. Schroeder, K. Case Rep Anesthesiol Case Report Pain management in trauma patients with acute rib and spine fractures presents a challenge for the anesthesiologist and achieving adequate analgesia is important in preventing pulmonary complications. Unfortunately, neuraxial techniques are often challenging or contraindicated due to spine fractures or coagulopathy. Erector spinae plane (ESP) blocks provide an alternative regional anesthetic technique to manage pain. We describe a case of bilateral ESP catheters placed intraoperatively after spinal instrumentation in a patient with bilateral rib and spine fractures sustained in a tractor rollover crash. Prior to surgery, the patient had inadequate pain control and poor respiratory function despite multimodal analgesia. With the addition of bilateral ESP catheters, the patient's pain control improved and he was weaned from respiratory support. ESP blocks have been shown to provide effective analgesia in patients with rib fractures; however, the utilization of these blocks has not been described in patients with spine fractures undergoing spinal instrumentation. Thus, ESP blocks provide a simple alternative to providing surgical and trauma analgesia when neuraxial techniques are contraindicated. The success of bilateral ESP catheters in our patient indicates a further area for application of ESP blocks in patients undergoing spine surgery with acute traumatic spine fractures. Hindawi 2019-04-08 /pmc/articles/PMC6476142/ /pubmed/31093377 http://dx.doi.org/10.1155/2019/9159878 Text en Copyright © 2019 L. Klesius and K. Schroeder. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Klesius, L.
Schroeder, K.
Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title_full Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title_fullStr Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title_full_unstemmed Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title_short Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
title_sort effective analgesia with bilateral erector spinae plane catheters for a patient with traumatic rib and spine fractures
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6476142/
https://www.ncbi.nlm.nih.gov/pubmed/31093377
http://dx.doi.org/10.1155/2019/9159878
work_keys_str_mv AT klesiusl effectiveanalgesiawithbilateralerectorspinaeplanecathetersforapatientwithtraumaticribandspinefractures
AT schroederk effectiveanalgesiawithbilateralerectorspinaeplanecathetersforapatientwithtraumaticribandspinefractures