Cargando…
Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials
This study was conducted to investigate the maxillary denture bases and occlusal discrepancies using the Vertex Thermosens in comparison with the conventional polymethyl-methacrylate materials. Twenty maxillary denture bases were prepared from the Vertex ThermoSens and a conventional heat-cured dent...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial Department of Journal of Biomedical Research
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6477176/ https://www.ncbi.nlm.nih.gov/pubmed/30418169 http://dx.doi.org/10.7555/JBR.32.20160132 |
_version_ | 1783413013915631616 |
---|---|
author | Lamfon, Hanadi A. Hamouda, Ibrahim M. |
author_facet | Lamfon, Hanadi A. Hamouda, Ibrahim M. |
author_sort | Lamfon, Hanadi A. |
collection | PubMed |
description | This study was conducted to investigate the maxillary denture bases and occlusal discrepancies using the Vertex Thermosens in comparison with the conventional polymethyl-methacrylate materials. Twenty maxillary denture bases were prepared from the Vertex ThermoSens and a conventional heat-cured denture base materials. Acrylic maxillary second molars were arranged in their respective positions on the ridge. After curing of both types of denture bases, they were deflasked with their respective master casts. Reference points were prepared for measurements of the antero-posterior and cross-arch dimensions at the denture borders using caliper device. Furthermore, the teeth discrepancies were measured between reference points in the ligual aspect of the second maxillary molars. The recorded data was analyzed using SPSS statistical software version 20. The results showed initial shrinkage of both denture bases in the antero-posterior and cross-arch dimensions immediately after decasting. This contraction was compensated gradually during storage in water up to 2 weeks. Regarding the variable time, there was a significant difference between the tested materials. Moreover, the results revealed occlusal discrepancies and shifting of teeth inward immediately after decasting, followed by outward movement after storage in water for 2 weeks. Regarding the variables time and materials, there were significant differences. Both materials exhibited inward shrinkage in the antero-posterior and cross-arch dimensions immediately after decasting. Both denture bases showed inward shifting of teeth immediately after decasting, followed by outward movement after storage in water up to 2 weeks. |
format | Online Article Text |
id | pubmed-6477176 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Editorial Department of Journal of Biomedical Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-64771762019-06-05 Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials Lamfon, Hanadi A. Hamouda, Ibrahim M. J Biomed Res Original Article This study was conducted to investigate the maxillary denture bases and occlusal discrepancies using the Vertex Thermosens in comparison with the conventional polymethyl-methacrylate materials. Twenty maxillary denture bases were prepared from the Vertex ThermoSens and a conventional heat-cured denture base materials. Acrylic maxillary second molars were arranged in their respective positions on the ridge. After curing of both types of denture bases, they were deflasked with their respective master casts. Reference points were prepared for measurements of the antero-posterior and cross-arch dimensions at the denture borders using caliper device. Furthermore, the teeth discrepancies were measured between reference points in the ligual aspect of the second maxillary molars. The recorded data was analyzed using SPSS statistical software version 20. The results showed initial shrinkage of both denture bases in the antero-posterior and cross-arch dimensions immediately after decasting. This contraction was compensated gradually during storage in water up to 2 weeks. Regarding the variable time, there was a significant difference between the tested materials. Moreover, the results revealed occlusal discrepancies and shifting of teeth inward immediately after decasting, followed by outward movement after storage in water for 2 weeks. Regarding the variables time and materials, there were significant differences. Both materials exhibited inward shrinkage in the antero-posterior and cross-arch dimensions immediately after decasting. Both denture bases showed inward shifting of teeth immediately after decasting, followed by outward movement after storage in water up to 2 weeks. Editorial Department of Journal of Biomedical Research 2019 /pmc/articles/PMC6477176/ /pubmed/30418169 http://dx.doi.org/10.7555/JBR.32.20160132 Text en /creativecommons.org/licenses/by/4.0/ This is an open access article under the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited |
spellingShingle | Original Article Lamfon, Hanadi A. Hamouda, Ibrahim M. Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title | Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title_full | Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title_fullStr | Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title_full_unstemmed | Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title_short | Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials |
title_sort | maxillary denture flange and occlusal discrepancies of vertex thermosens in comparison with conventional heat-cured denture base materials |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6477176/ https://www.ncbi.nlm.nih.gov/pubmed/30418169 http://dx.doi.org/10.7555/JBR.32.20160132 |
work_keys_str_mv | AT lamfonhanadia maxillarydentureflangeandocclusaldiscrepanciesofvertexthermosensincomparisonwithconventionalheatcureddenturebasematerials AT hamoudaibrahimm maxillarydentureflangeandocclusaldiscrepanciesofvertexthermosensincomparisonwithconventionalheatcureddenturebasematerials |