Cargando…

Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT

Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematical modelli...

Descripción completa

Detalles Bibliográficos
Autores principales: Robinson, Stephanie K., Ramsden, Jonathan J., Warner, Jane, Lackie, Peter M., Roose, Tiina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6478691/
https://www.ncbi.nlm.nih.gov/pubmed/31015547
http://dx.doi.org/10.1038/s41598-019-42794-7
_version_ 1783413190865977344
author Robinson, Stephanie K.
Ramsden, Jonathan J.
Warner, Jane
Lackie, Peter M.
Roose, Tiina
author_facet Robinson, Stephanie K.
Ramsden, Jonathan J.
Warner, Jane
Lackie, Peter M.
Roose, Tiina
author_sort Robinson, Stephanie K.
collection PubMed
description Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematical modelling of pulmonary lymphatic microfluidics has been limited by the lack of accurate and representative image geometries. This is due to the microstructural similarity of the lymphatics to the blood vessel network, the lack of lymphatic-specific biomarkers, the technical limitations associated with image resolution in 3D, and sectioning artefacts present in 2D techniques. We present a method that combines lymphatic specific (D240 antibody) immunohistochemistry (IHC), optimised high-resolution X-ray microfocus computed tomography (μCT) and finite-element mathematical modelling to assess the function of human peripheral lung tissue. The initial results identify lymphatic heterogeneity within and between lung tissue. Lymphatic vessel volume fraction and fractal dimension significantly decreases away from the lung pleural surface (p < 0.001, n = 25 and p < 0.01, n = 20, respectively). Microfluidic modelling successfully shows that in lung tissue the fluid derived from the blood vessels drains through the interstitium into the lymphatic vessel network and this drainage is different in the subpleural space compared to the intralobular space. When comparing lung tissue from health and disease, human pulmonary lymphatics were significantly different across five morphometric measures used in this study (p ≤ 0.0001). This proof of principle study establishes a new engineering technology and workflow for further studies of pulmonary lymphatics and demonstrates for the first time the combination of correlative μCT and IHC to enable 3D mathematical modelling of human lung microfluidics at micrometre resolution.
format Online
Article
Text
id pubmed-6478691
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-64786912019-05-03 Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT Robinson, Stephanie K. Ramsden, Jonathan J. Warner, Jane Lackie, Peter M. Roose, Tiina Sci Rep Article Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematical modelling of pulmonary lymphatic microfluidics has been limited by the lack of accurate and representative image geometries. This is due to the microstructural similarity of the lymphatics to the blood vessel network, the lack of lymphatic-specific biomarkers, the technical limitations associated with image resolution in 3D, and sectioning artefacts present in 2D techniques. We present a method that combines lymphatic specific (D240 antibody) immunohistochemistry (IHC), optimised high-resolution X-ray microfocus computed tomography (μCT) and finite-element mathematical modelling to assess the function of human peripheral lung tissue. The initial results identify lymphatic heterogeneity within and between lung tissue. Lymphatic vessel volume fraction and fractal dimension significantly decreases away from the lung pleural surface (p < 0.001, n = 25 and p < 0.01, n = 20, respectively). Microfluidic modelling successfully shows that in lung tissue the fluid derived from the blood vessels drains through the interstitium into the lymphatic vessel network and this drainage is different in the subpleural space compared to the intralobular space. When comparing lung tissue from health and disease, human pulmonary lymphatics were significantly different across five morphometric measures used in this study (p ≤ 0.0001). This proof of principle study establishes a new engineering technology and workflow for further studies of pulmonary lymphatics and demonstrates for the first time the combination of correlative μCT and IHC to enable 3D mathematical modelling of human lung microfluidics at micrometre resolution. Nature Publishing Group UK 2019-04-23 /pmc/articles/PMC6478691/ /pubmed/31015547 http://dx.doi.org/10.1038/s41598-019-42794-7 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Robinson, Stephanie K.
Ramsden, Jonathan J.
Warner, Jane
Lackie, Peter M.
Roose, Tiina
Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_full Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_fullStr Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_full_unstemmed Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_short Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_sort correlative 3d imaging and microfluidic modelling of human pulmonary lymphatics using immunohistochemistry and high-resolution μct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6478691/
https://www.ncbi.nlm.nih.gov/pubmed/31015547
http://dx.doi.org/10.1038/s41598-019-42794-7
work_keys_str_mv AT robinsonstephaniek correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT ramsdenjonathanj correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT warnerjane correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT lackiepeterm correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT roosetiina correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct