Cargando…
In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration
This study’s aim was to evaluate the biocompatibility and bioabsorption of a new membrane for guided bone regeneration (polylactic-co-glycolic acid associated with hydroxyapatite and β-tricalcium phosphate) with three thicknesses (200, 500, and 700 µm) implanted in mice subcutaneously. Scanning elec...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479290/ https://www.ncbi.nlm.nih.gov/pubmed/30978950 http://dx.doi.org/10.3390/ma12071186 |
_version_ | 1783413311408177152 |
---|---|
author | da Costa Pereira, Lívia de Almeida Barros Mourão, Carlos Fernando Neves Novellino Alves, Adriana Terezinha Figueiredo de Brito Resende, Rodrigo Pinheiro Guedes de Uzeda, Marcelo José Granjeiro, José Mauro Seabra Louro, Rafael Diuana Calasans-Maia, Mônica |
author_facet | da Costa Pereira, Lívia de Almeida Barros Mourão, Carlos Fernando Neves Novellino Alves, Adriana Terezinha Figueiredo de Brito Resende, Rodrigo Pinheiro Guedes de Uzeda, Marcelo José Granjeiro, José Mauro Seabra Louro, Rafael Diuana Calasans-Maia, Mônica |
author_sort | da Costa Pereira, Lívia |
collection | PubMed |
description | This study’s aim was to evaluate the biocompatibility and bioabsorption of a new membrane for guided bone regeneration (polylactic-co-glycolic acid associated with hydroxyapatite and β-tricalcium phosphate) with three thicknesses (200, 500, and 700 µm) implanted in mice subcutaneously. Scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and the quantification of carbon, hydrogen and nitrogen were used to characterize the physico-chemical properties. One hundred Balb-C mice were divided into 5 experimental groups: Group 1—Sham (without implantation); Group 2—200 μm; Group 3—500 μm; Group 4—700 μm; and Group 5—Pratix(®). Each group was subdivided into four experimental periods (7, 30, 60 and 90 days). Samples were collected and processed for histological and histomorphometrical evaluation. The membranes showed no moderate or severe tissue reactions during the experimental periods studied. The 500-μm membrane showed no tissue reaction during any experimental period. The 200-μm membrane began to exhibit fragmentation after 30 days, while the 500-μm and 700-µm membranes began fragmentation at 90 days. All membranes studied were biocompatible and the 500 µm membrane showed the best results for absorption and tissue reaction, indicating its potential for clinical guided bone regeneration. |
format | Online Article Text |
id | pubmed-6479290 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64792902019-04-29 In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration da Costa Pereira, Lívia de Almeida Barros Mourão, Carlos Fernando Neves Novellino Alves, Adriana Terezinha Figueiredo de Brito Resende, Rodrigo Pinheiro Guedes de Uzeda, Marcelo José Granjeiro, José Mauro Seabra Louro, Rafael Diuana Calasans-Maia, Mônica Materials (Basel) Article This study’s aim was to evaluate the biocompatibility and bioabsorption of a new membrane for guided bone regeneration (polylactic-co-glycolic acid associated with hydroxyapatite and β-tricalcium phosphate) with three thicknesses (200, 500, and 700 µm) implanted in mice subcutaneously. Scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and the quantification of carbon, hydrogen and nitrogen were used to characterize the physico-chemical properties. One hundred Balb-C mice were divided into 5 experimental groups: Group 1—Sham (without implantation); Group 2—200 μm; Group 3—500 μm; Group 4—700 μm; and Group 5—Pratix(®). Each group was subdivided into four experimental periods (7, 30, 60 and 90 days). Samples were collected and processed for histological and histomorphometrical evaluation. The membranes showed no moderate or severe tissue reactions during the experimental periods studied. The 500-μm membrane showed no tissue reaction during any experimental period. The 200-μm membrane began to exhibit fragmentation after 30 days, while the 500-μm and 700-µm membranes began fragmentation at 90 days. All membranes studied were biocompatible and the 500 µm membrane showed the best results for absorption and tissue reaction, indicating its potential for clinical guided bone regeneration. MDPI 2019-04-11 /pmc/articles/PMC6479290/ /pubmed/30978950 http://dx.doi.org/10.3390/ma12071186 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article da Costa Pereira, Lívia de Almeida Barros Mourão, Carlos Fernando Neves Novellino Alves, Adriana Terezinha Figueiredo de Brito Resende, Rodrigo Pinheiro Guedes de Uzeda, Marcelo José Granjeiro, José Mauro Seabra Louro, Rafael Diuana Calasans-Maia, Mônica In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title | In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title_full | In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title_fullStr | In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title_full_unstemmed | In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title_short | In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration |
title_sort | in vitro physico-chemical characterization and standardized in vivo evaluation of biocompatibility of a new synthetic membrane for guided bone regeneration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479290/ https://www.ncbi.nlm.nih.gov/pubmed/30978950 http://dx.doi.org/10.3390/ma12071186 |
work_keys_str_mv | AT dacostapereiralivia invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT dealmeidabarrosmouraocarlosfernando invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT nevesnovellinoalvesadrianaterezinha invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT figueiredodebritoresenderodrigo invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT pinheiroguedesdeuzedamarcelojose invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT granjeirojosemauro invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT seabralourorafael invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration AT diuanacalasansmaiamonica invitrophysicochemicalcharacterizationandstandardizedinvivoevaluationofbiocompatibilityofanewsyntheticmembraneforguidedboneregeneration |