Cargando…
Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment
This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is p...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479482/ https://www.ncbi.nlm.nih.gov/pubmed/30939788 http://dx.doi.org/10.3390/s19071571 |
_version_ | 1783413355552178176 |
---|---|
author | Hsiao, Hsien-Yi Chen, Richie L. C. Chou, Chih-Chi Cheng, Tzong-Jih |
author_facet | Hsiao, Hsien-Yi Chen, Richie L. C. Chou, Chih-Chi Cheng, Tzong-Jih |
author_sort | Hsiao, Hsien-Yi |
collection | PubMed |
description | This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm(3) and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL(−1). The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research. |
format | Online Article Text |
id | pubmed-6479482 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64794822019-04-29 Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment Hsiao, Hsien-Yi Chen, Richie L. C. Chou, Chih-Chi Cheng, Tzong-Jih Sensors (Basel) Article This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm(3) and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL(−1). The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research. MDPI 2019-04-01 /pmc/articles/PMC6479482/ /pubmed/30939788 http://dx.doi.org/10.3390/s19071571 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hsiao, Hsien-Yi Chen, Richie L. C. Chou, Chih-Chi Cheng, Tzong-Jih Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title | Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title_full | Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title_fullStr | Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title_full_unstemmed | Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title_short | Hand-held Colorimetry Sensor Platform for Determining Salivary α-Amylase Activity and Its Applications for Stress Assessment |
title_sort | hand-held colorimetry sensor platform for determining salivary α-amylase activity and its applications for stress assessment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479482/ https://www.ncbi.nlm.nih.gov/pubmed/30939788 http://dx.doi.org/10.3390/s19071571 |
work_keys_str_mv | AT hsiaohsienyi handheldcolorimetrysensorplatformfordeterminingsalivaryaamylaseactivityanditsapplicationsforstressassessment AT chenrichielc handheldcolorimetrysensorplatformfordeterminingsalivaryaamylaseactivityanditsapplicationsforstressassessment AT chouchihchi handheldcolorimetrysensorplatformfordeterminingsalivaryaamylaseactivityanditsapplicationsforstressassessment AT chengtzongjih handheldcolorimetrysensorplatformfordeterminingsalivaryaamylaseactivityanditsapplicationsforstressassessment |