Cargando…

The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar

Ionically-conductive mortar can be used for indoor radiant heating partition walls. In these applications, mortar blocks are soaked in electrolyte solutions of CuSO(4). The surfaces of the block are coated with sealant and epoxy resin afterwards to prevent evaporation. The mortar block becomes a hea...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Ruohong, Weng, Yubin, Tuan, Christopher Y., Xu, An
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479828/
https://www.ncbi.nlm.nih.gov/pubmed/30959856
http://dx.doi.org/10.3390/ma12071125
_version_ 1783413435054161920
author Zhao, Ruohong
Weng, Yubin
Tuan, Christopher Y.
Xu, An
author_facet Zhao, Ruohong
Weng, Yubin
Tuan, Christopher Y.
Xu, An
author_sort Zhao, Ruohong
collection PubMed
description Ionically-conductive mortar can be used for indoor radiant heating partition walls. In these applications, mortar blocks are soaked in electrolyte solutions of CuSO(4). The surfaces of the block are coated with sealant and epoxy resin afterwards to prevent evaporation. The mortar block becomes a heating element due to ionic conduction if a voltage is applied to the electrodes in the block. Its electrical conductivity depends on the dispersion of the electrolyte, and hence on the porosity of the mortar. The test specimens in this study were divided into four groups according to the different air entrainment agents, including aluminum powder and hydrogen peroxide as well as two air-entraining agents, SJ-2 and K12. Each group was manufactured with water/cement ratios in the range of 0.5 to 0.9. The test results showed that the conductivity of the mortar was strongly influenced by the air-entrainment and the water cement ratios. The volumetric electric resistivity and the associated microstructures of the mortar were investigated. The test results showed that the specimens made with aluminum powder and a water–cement ratio of 0.65–0.75 had high porosity. The porosity of those specimens was further increased by adding two different air-entraining agents. The specimens with aluminum powder and SJ-2, along with a water–cement ratio of 0.7 appeared to be the optimum mixture. Its resistivity was 19.37 Ω·m at 28 days under 25.31% porosity. The experimental results indicate that an ionically-conductive mortar can be produced by combining different air-entrainment agents with variable water-cement ratios to meet a specified electrical heating requirement.
format Online
Article
Text
id pubmed-6479828
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64798282019-04-29 The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar Zhao, Ruohong Weng, Yubin Tuan, Christopher Y. Xu, An Materials (Basel) Article Ionically-conductive mortar can be used for indoor radiant heating partition walls. In these applications, mortar blocks are soaked in electrolyte solutions of CuSO(4). The surfaces of the block are coated with sealant and epoxy resin afterwards to prevent evaporation. The mortar block becomes a heating element due to ionic conduction if a voltage is applied to the electrodes in the block. Its electrical conductivity depends on the dispersion of the electrolyte, and hence on the porosity of the mortar. The test specimens in this study were divided into four groups according to the different air entrainment agents, including aluminum powder and hydrogen peroxide as well as two air-entraining agents, SJ-2 and K12. Each group was manufactured with water/cement ratios in the range of 0.5 to 0.9. The test results showed that the conductivity of the mortar was strongly influenced by the air-entrainment and the water cement ratios. The volumetric electric resistivity and the associated microstructures of the mortar were investigated. The test results showed that the specimens made with aluminum powder and a water–cement ratio of 0.65–0.75 had high porosity. The porosity of those specimens was further increased by adding two different air-entraining agents. The specimens with aluminum powder and SJ-2, along with a water–cement ratio of 0.7 appeared to be the optimum mixture. Its resistivity was 19.37 Ω·m at 28 days under 25.31% porosity. The experimental results indicate that an ionically-conductive mortar can be produced by combining different air-entrainment agents with variable water-cement ratios to meet a specified electrical heating requirement. MDPI 2019-04-05 /pmc/articles/PMC6479828/ /pubmed/30959856 http://dx.doi.org/10.3390/ma12071125 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Ruohong
Weng, Yubin
Tuan, Christopher Y.
Xu, An
The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title_full The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title_fullStr The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title_full_unstemmed The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title_short The Influence of Water/Cement Ratio and Air Entrainment on the Electric Resistivity of Ionically Conductive Mortar
title_sort influence of water/cement ratio and air entrainment on the electric resistivity of ionically conductive mortar
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479828/
https://www.ncbi.nlm.nih.gov/pubmed/30959856
http://dx.doi.org/10.3390/ma12071125
work_keys_str_mv AT zhaoruohong theinfluenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT wengyubin theinfluenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT tuanchristophery theinfluenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT xuan theinfluenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT zhaoruohong influenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT wengyubin influenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT tuanchristophery influenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar
AT xuan influenceofwatercementratioandairentrainmentontheelectricresistivityofionicallyconductivemortar