Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls

Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/Fs) emissions from basic small-scale waste incinerators (SWI) may cause health risks in nearby people and are thus subject to stringent regulations. The aim of this study was to evaluate PCDD/F emission and reduction of a basic SWI in the absen...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Gang, Huang, Xiangxuan, Liao, Wenbo, Kang, Shimin, Ren, Mingzhong, Hai, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479856/
https://www.ncbi.nlm.nih.gov/pubmed/30970588
http://dx.doi.org/10.3390/ijerph16071267
_version_ 1783413441667530752
author Zhang, Gang
Huang, Xiangxuan
Liao, Wenbo
Kang, Shimin
Ren, Mingzhong
Hai, Jing
author_facet Zhang, Gang
Huang, Xiangxuan
Liao, Wenbo
Kang, Shimin
Ren, Mingzhong
Hai, Jing
author_sort Zhang, Gang
collection PubMed
description Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/Fs) emissions from basic small-scale waste incinerators (SWI) may cause health risks in nearby people and are thus subject to stringent regulations. The aim of this study was to evaluate PCDD/F emission and reduction of a basic SWI in the absence of air pollution controls (APCs). The results indicated that the stack gas and fly ash presented average PCDD/F levels and emission factors of 3.6 ng international toxic equivalent (I-TEQ)/Nm(3) and 189.31µg I-TEQ/t and 6.89 ng I-TEQ/g and 137.85µg I-TEQ/t, respectively, much higher than those from large municipal solid waste incinerators (MSWI). PCDD/Fs congener fingerprints indicated that de novo synthesis played a dominant role in the low-temperature post-combustion zone and increased the presence of high-chlorine substituted congeners. On the basis of the emission factor 327.24 µg I-TEQ/t-waste, approximately 3000 g I-TEQ dioxins might be generated in total through basic SWIs and open burning. After refitting an SWI by adding activated carbon injection with a bag filter (ACI+BG), the PCDD/F emissions decreased to mean values of 0.042 ng I-TEQ/Nm(3), far below the standard of 0.1 ng I-TEQ/Nm(3), and the removal efficiency reached 99.13% in terms of I-TEQ. Therefore, it is entirely feasible to considerably reduce PCDD/F emissions by refitting basic SWI, which is positive for the future development of rural solid waste (RSW (RSW) disposal by SWI.
format Online
Article
Text
id pubmed-6479856
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64798562019-04-29 Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls Zhang, Gang Huang, Xiangxuan Liao, Wenbo Kang, Shimin Ren, Mingzhong Hai, Jing Int J Environ Res Public Health Article Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/Fs) emissions from basic small-scale waste incinerators (SWI) may cause health risks in nearby people and are thus subject to stringent regulations. The aim of this study was to evaluate PCDD/F emission and reduction of a basic SWI in the absence of air pollution controls (APCs). The results indicated that the stack gas and fly ash presented average PCDD/F levels and emission factors of 3.6 ng international toxic equivalent (I-TEQ)/Nm(3) and 189.31µg I-TEQ/t and 6.89 ng I-TEQ/g and 137.85µg I-TEQ/t, respectively, much higher than those from large municipal solid waste incinerators (MSWI). PCDD/Fs congener fingerprints indicated that de novo synthesis played a dominant role in the low-temperature post-combustion zone and increased the presence of high-chlorine substituted congeners. On the basis of the emission factor 327.24 µg I-TEQ/t-waste, approximately 3000 g I-TEQ dioxins might be generated in total through basic SWIs and open burning. After refitting an SWI by adding activated carbon injection with a bag filter (ACI+BG), the PCDD/F emissions decreased to mean values of 0.042 ng I-TEQ/Nm(3), far below the standard of 0.1 ng I-TEQ/Nm(3), and the removal efficiency reached 99.13% in terms of I-TEQ. Therefore, it is entirely feasible to considerably reduce PCDD/F emissions by refitting basic SWI, which is positive for the future development of rural solid waste (RSW (RSW) disposal by SWI. MDPI 2019-04-09 2019-04 /pmc/articles/PMC6479856/ /pubmed/30970588 http://dx.doi.org/10.3390/ijerph16071267 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Gang
Huang, Xiangxuan
Liao, Wenbo
Kang, Shimin
Ren, Mingzhong
Hai, Jing
Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title_full Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title_fullStr Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title_full_unstemmed Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title_short Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls
title_sort measurement of dioxin emissions from a small-scale waste incinerator in the absence of air pollution controls
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479856/
https://www.ncbi.nlm.nih.gov/pubmed/30970588
http://dx.doi.org/10.3390/ijerph16071267
work_keys_str_mv AT zhanggang measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols
AT huangxiangxuan measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols
AT liaowenbo measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols
AT kangshimin measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols
AT renmingzhong measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols
AT haijing measurementofdioxinemissionsfromasmallscalewasteincineratorintheabsenceofairpollutioncontrols