High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter

By using an innovative, positive pressure sample loading technique in combination with an in-line filter of finely ground sand the bottleneck of solid phase extraction (SPE) can be reduced. Recently published work by us has shown the proof of concept of the technique. In this work, emphasis is put o...

Descripción completa

Detalles Bibliográficos
Autores principales: Svahn, Ola, Björklund, Erland
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479934/
https://www.ncbi.nlm.nih.gov/pubmed/30978956
http://dx.doi.org/10.3390/molecules24071426
_version_ 1783413459806846976
author Svahn, Ola
Björklund, Erland
author_facet Svahn, Ola
Björklund, Erland
author_sort Svahn, Ola
collection PubMed
description By using an innovative, positive pressure sample loading technique in combination with an in-line filter of finely ground sand the bottleneck of solid phase extraction (SPE) can be reduced. Recently published work by us has shown the proof of concept of the technique. In this work, emphasis is put on the SPE flow rate and method validation for 26 compounds of emerging environmental concern, mainly from the 1st and 2nd EU Watch List, with various physicochemical properties. The mean absolute recoveries in % and relative standard deviations (RSD) in % for the investigated compounds from spiked pure water samples at the three investigated flow rates of 10, 20, and 40 mL/min were 63.2% (3.2%), 66.9% (3.3%), and 69.0% (4.0%), respectively. All three flow rates produced highly repeatable results, and this allowed a flow rate increase of up to 40 mL/min for a 200 mg, 6 mL, reversed phase SPE cartridge without compromising the recoveries. This figure is more than four times the maximum flow rate recommended by manufacturers. It was indicated that some compounds, especially pronounced for the investigated macrolide molecules, might suffer when long contact times with the sample glass bottle occurs. A reduced contact time somewhat decreases this complication. A very good repeatability also held true for experiments on both spiked matrix-rich pond water (high and low concentrations) and recipient waters (river and wastewater) applying 40 mL/min. This work has shown that, for a large number of compounds of widely differing physicochemical properties, there is a generous flow rate window from 10 to 40 mL/min where sample loading can be conducted. A sample volume of 0.5 L, which at the recommended maximum flow rate speed of 10 mL/min, would previously take 50 min, can now be processed in 12 min using a flow rate of 40 mL/min. This saves 38 min per processed sample. This low-cost technology allows the sample to be transferred to the SPE-column, closer to the sample location and by the person taking the sample. This further means that only the sample cartridge would need to be sent to the laboratory, instead of the whole water sample, like today’s procedure.
format Online
Article
Text
id pubmed-6479934
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64799342019-04-30 High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter Svahn, Ola Björklund, Erland Molecules Article By using an innovative, positive pressure sample loading technique in combination with an in-line filter of finely ground sand the bottleneck of solid phase extraction (SPE) can be reduced. Recently published work by us has shown the proof of concept of the technique. In this work, emphasis is put on the SPE flow rate and method validation for 26 compounds of emerging environmental concern, mainly from the 1st and 2nd EU Watch List, with various physicochemical properties. The mean absolute recoveries in % and relative standard deviations (RSD) in % for the investigated compounds from spiked pure water samples at the three investigated flow rates of 10, 20, and 40 mL/min were 63.2% (3.2%), 66.9% (3.3%), and 69.0% (4.0%), respectively. All three flow rates produced highly repeatable results, and this allowed a flow rate increase of up to 40 mL/min for a 200 mg, 6 mL, reversed phase SPE cartridge without compromising the recoveries. This figure is more than four times the maximum flow rate recommended by manufacturers. It was indicated that some compounds, especially pronounced for the investigated macrolide molecules, might suffer when long contact times with the sample glass bottle occurs. A reduced contact time somewhat decreases this complication. A very good repeatability also held true for experiments on both spiked matrix-rich pond water (high and low concentrations) and recipient waters (river and wastewater) applying 40 mL/min. This work has shown that, for a large number of compounds of widely differing physicochemical properties, there is a generous flow rate window from 10 to 40 mL/min where sample loading can be conducted. A sample volume of 0.5 L, which at the recommended maximum flow rate speed of 10 mL/min, would previously take 50 min, can now be processed in 12 min using a flow rate of 40 mL/min. This saves 38 min per processed sample. This low-cost technology allows the sample to be transferred to the SPE-column, closer to the sample location and by the person taking the sample. This further means that only the sample cartridge would need to be sent to the laboratory, instead of the whole water sample, like today’s procedure. MDPI 2019-04-11 /pmc/articles/PMC6479934/ /pubmed/30978956 http://dx.doi.org/10.3390/molecules24071426 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Svahn, Ola
Björklund, Erland
High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title_full High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title_fullStr High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title_full_unstemmed High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title_short High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely Ground Sand as a SPE-Column In-Line Filter
title_sort high flow-rate sample loading in large volume whole water organic trace analysis using positive pressure and finely ground sand as a spe-column in-line filter
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6479934/
https://www.ncbi.nlm.nih.gov/pubmed/30978956
http://dx.doi.org/10.3390/molecules24071426
work_keys_str_mv AT svahnola highflowratesampleloadinginlargevolumewholewaterorganictraceanalysisusingpositivepressureandfinelygroundsandasaspecolumninlinefilter
AT bjorklunderland highflowratesampleloadinginlargevolumewholewaterorganictraceanalysisusingpositivepressureandfinelygroundsandasaspecolumninlinefilter