Cargando…

Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry

In this study, a novel sort of sample preparation sorbent was developed, by preparing thin layer graphene oxide tablets (GO-Tabs) utilizing a mixture of graphene oxide and polyethylene glycol on a polyethylene substrate. The GO-Tabs were used for extraction and concentration of omeprazole (OME) in h...

Descripción completa

Detalles Bibliográficos
Autores principales: Zohdi, Zeynab, Hashemi, Mahdi, Uheida, Abdusalam, Moein, Mohammad Mahdi, Abdel-Rehim, Mohamed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480210/
https://www.ncbi.nlm.nih.gov/pubmed/30934659
http://dx.doi.org/10.3390/molecules24071191
_version_ 1783413523917832192
author Zohdi, Zeynab
Hashemi, Mahdi
Uheida, Abdusalam
Moein, Mohammad Mahdi
Abdel-Rehim, Mohamed
author_facet Zohdi, Zeynab
Hashemi, Mahdi
Uheida, Abdusalam
Moein, Mohammad Mahdi
Abdel-Rehim, Mohamed
author_sort Zohdi, Zeynab
collection PubMed
description In this study, a novel sort of sample preparation sorbent was developed, by preparing thin layer graphene oxide tablets (GO-Tabs) utilizing a mixture of graphene oxide and polyethylene glycol on a polyethylene substrate. The GO-Tabs were used for extraction and concentration of omeprazole (OME) in human saliva samples. The determination of OME was carried out using liquid chromatography-tandem mass spectrometry (LC–MS/MS) under gradient LC conditions and in the positive ion mode (ESI+) with mass transitions of m/z 346.3→198.0 for OME and m/z 369.98→252.0 for the internal standard. Standard calibration for the saliva samples was in the range of 2.0–2000 nmol L(−1). Limits of detection and quantification were 0.05 and 2.0 nmol L(−1), respectively. Method validation showed good method accuracy and precision; the inter-day precision values ranged from 5.7 to 8.3 (%RSD), and the accuracy of determinations varied from −11.8% to 13.3% (% deviation from nominal values). The extraction recovery was 60%, and GO-Tabs could be re-used for more than ten extractions without deterioration in recovery. In this study, the determination of OME in real human saliva samples using GO-Tab extraction was validated.
format Online
Article
Text
id pubmed-6480210
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64802102019-04-30 Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry Zohdi, Zeynab Hashemi, Mahdi Uheida, Abdusalam Moein, Mohammad Mahdi Abdel-Rehim, Mohamed Molecules Article In this study, a novel sort of sample preparation sorbent was developed, by preparing thin layer graphene oxide tablets (GO-Tabs) utilizing a mixture of graphene oxide and polyethylene glycol on a polyethylene substrate. The GO-Tabs were used for extraction and concentration of omeprazole (OME) in human saliva samples. The determination of OME was carried out using liquid chromatography-tandem mass spectrometry (LC–MS/MS) under gradient LC conditions and in the positive ion mode (ESI+) with mass transitions of m/z 346.3→198.0 for OME and m/z 369.98→252.0 for the internal standard. Standard calibration for the saliva samples was in the range of 2.0–2000 nmol L(−1). Limits of detection and quantification were 0.05 and 2.0 nmol L(−1), respectively. Method validation showed good method accuracy and precision; the inter-day precision values ranged from 5.7 to 8.3 (%RSD), and the accuracy of determinations varied from −11.8% to 13.3% (% deviation from nominal values). The extraction recovery was 60%, and GO-Tabs could be re-used for more than ten extractions without deterioration in recovery. In this study, the determination of OME in real human saliva samples using GO-Tab extraction was validated. MDPI 2019-03-27 /pmc/articles/PMC6480210/ /pubmed/30934659 http://dx.doi.org/10.3390/molecules24071191 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zohdi, Zeynab
Hashemi, Mahdi
Uheida, Abdusalam
Moein, Mohammad Mahdi
Abdel-Rehim, Mohamed
Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title_full Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title_fullStr Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title_full_unstemmed Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title_short Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry
title_sort graphene oxide tablets for sample preparation of drugs in biological fluids: determination of omeprazole in human saliva for liquid chromatography tandem mass spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480210/
https://www.ncbi.nlm.nih.gov/pubmed/30934659
http://dx.doi.org/10.3390/molecules24071191
work_keys_str_mv AT zohdizeynab grapheneoxidetabletsforsamplepreparationofdrugsinbiologicalfluidsdeterminationofomeprazoleinhumansalivaforliquidchromatographytandemmassspectrometry
AT hashemimahdi grapheneoxidetabletsforsamplepreparationofdrugsinbiologicalfluidsdeterminationofomeprazoleinhumansalivaforliquidchromatographytandemmassspectrometry
AT uheidaabdusalam grapheneoxidetabletsforsamplepreparationofdrugsinbiologicalfluidsdeterminationofomeprazoleinhumansalivaforliquidchromatographytandemmassspectrometry
AT moeinmohammadmahdi grapheneoxidetabletsforsamplepreparationofdrugsinbiologicalfluidsdeterminationofomeprazoleinhumansalivaforliquidchromatographytandemmassspectrometry
AT abdelrehimmohamed grapheneoxidetabletsforsamplepreparationofdrugsinbiologicalfluidsdeterminationofomeprazoleinhumansalivaforliquidchromatographytandemmassspectrometry