Cargando…
A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480425/ https://www.ncbi.nlm.nih.gov/pubmed/30978993 http://dx.doi.org/10.3390/s19071739 |
_version_ | 1783413565896523776 |
---|---|
author | Guo, Xiangzhou Asif, Muhammad Hu, Anyong Li, Zhiping Miao, Jungang |
author_facet | Guo, Xiangzhou Asif, Muhammad Hu, Anyong Li, Zhiping Miao, Jungang |
author_sort | Guo, Xiangzhou |
collection | PubMed |
description | We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform the cross-correlation processing. This system can handle 2016 cross-correlations at the sample frequency of 1GHz, and its power consumption is 48.75 W. The data readout interface makes it possible to read earlier data while simultaneously performing the next correlation when imaging at video rate. The longest integration time is up to 68.7 s, which can satisfy the requirements of video rate imaging and system calibration. The measured crosstalk between neighboring channels is less than 0.068%, and the stability is longer than 10 s. A correlation efficiency greater than 96% is achieved for input signal levels greater than −25 dBm. |
format | Online Article Text |
id | pubmed-6480425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64804252019-04-29 A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging Guo, Xiangzhou Asif, Muhammad Hu, Anyong Li, Zhiping Miao, Jungang Sensors (Basel) Article We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform the cross-correlation processing. This system can handle 2016 cross-correlations at the sample frequency of 1GHz, and its power consumption is 48.75 W. The data readout interface makes it possible to read earlier data while simultaneously performing the next correlation when imaging at video rate. The longest integration time is up to 68.7 s, which can satisfy the requirements of video rate imaging and system calibration. The measured crosstalk between neighboring channels is less than 0.068%, and the stability is longer than 10 s. A correlation efficiency greater than 96% is achieved for input signal levels greater than −25 dBm. MDPI 2019-04-11 /pmc/articles/PMC6480425/ /pubmed/30978993 http://dx.doi.org/10.3390/s19071739 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Guo, Xiangzhou Asif, Muhammad Hu, Anyong Li, Zhiping Miao, Jungang A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title | A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title_full | A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title_fullStr | A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title_full_unstemmed | A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title_short | A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging |
title_sort | 1-ghz 64-channel cross-correlation system for real-time interferometric aperture synthesis imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480425/ https://www.ncbi.nlm.nih.gov/pubmed/30978993 http://dx.doi.org/10.3390/s19071739 |
work_keys_str_mv | AT guoxiangzhou a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT asifmuhammad a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT huanyong a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT lizhiping a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT miaojungang a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT guoxiangzhou 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT asifmuhammad 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT huanyong 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT lizhiping 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging AT miaojungang 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging |