Cargando…

A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging

We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform t...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Xiangzhou, Asif, Muhammad, Hu, Anyong, Li, Zhiping, Miao, Jungang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480425/
https://www.ncbi.nlm.nih.gov/pubmed/30978993
http://dx.doi.org/10.3390/s19071739
_version_ 1783413565896523776
author Guo, Xiangzhou
Asif, Muhammad
Hu, Anyong
Li, Zhiping
Miao, Jungang
author_facet Guo, Xiangzhou
Asif, Muhammad
Hu, Anyong
Li, Zhiping
Miao, Jungang
author_sort Guo, Xiangzhou
collection PubMed
description We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform the cross-correlation processing. This system can handle 2016 cross-correlations at the sample frequency of 1GHz, and its power consumption is 48.75 W. The data readout interface makes it possible to read earlier data while simultaneously performing the next correlation when imaging at video rate. The longest integration time is up to 68.7 s, which can satisfy the requirements of video rate imaging and system calibration. The measured crosstalk between neighboring channels is less than 0.068%, and the stability is longer than 10 s. A correlation efficiency greater than 96% is achieved for input signal levels greater than −25 dBm.
format Online
Article
Text
id pubmed-6480425
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64804252019-04-29 A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging Guo, Xiangzhou Asif, Muhammad Hu, Anyong Li, Zhiping Miao, Jungang Sensors (Basel) Article We present a 64-channel 1-bit/2-level cross-correlation system for a passive millimeter wave imager used for indoor human body security screening. Sixty-four commercial comparators are used to perform 1-bit analog-to-digital conversion, and a Field Programmable Gate Array (FPGA) is used to perform the cross-correlation processing. This system can handle 2016 cross-correlations at the sample frequency of 1GHz, and its power consumption is 48.75 W. The data readout interface makes it possible to read earlier data while simultaneously performing the next correlation when imaging at video rate. The longest integration time is up to 68.7 s, which can satisfy the requirements of video rate imaging and system calibration. The measured crosstalk between neighboring channels is less than 0.068%, and the stability is longer than 10 s. A correlation efficiency greater than 96% is achieved for input signal levels greater than −25 dBm. MDPI 2019-04-11 /pmc/articles/PMC6480425/ /pubmed/30978993 http://dx.doi.org/10.3390/s19071739 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guo, Xiangzhou
Asif, Muhammad
Hu, Anyong
Li, Zhiping
Miao, Jungang
A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title_full A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title_fullStr A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title_full_unstemmed A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title_short A 1-GHz 64-Channel Cross-Correlation System for Real-Time Interferometric Aperture Synthesis Imaging
title_sort 1-ghz 64-channel cross-correlation system for real-time interferometric aperture synthesis imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6480425/
https://www.ncbi.nlm.nih.gov/pubmed/30978993
http://dx.doi.org/10.3390/s19071739
work_keys_str_mv AT guoxiangzhou a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT asifmuhammad a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT huanyong a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT lizhiping a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT miaojungang a1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT guoxiangzhou 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT asifmuhammad 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT huanyong 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT lizhiping 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging
AT miaojungang 1ghz64channelcrosscorrelationsystemforrealtimeinterferometricaperturesynthesisimaging