Cargando…

The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration

A major drawback of nanocomposite scaffolds in bone tissue engineering is dimensional shrinkage after the fabrication process. Shrinkage yields gaps between the scaffold and host bone in the defect site and eventually causes failure in osteointegration by micromovement. The present study was conduct...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwon, Jane, Lee, Dong Joon, Kocher, Mallory, Kim, Yong-Il, Wu, Te-Ju, Whitley, John, Ko, Ching-Chang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481059/
https://www.ncbi.nlm.nih.gov/pubmed/31164601
http://dx.doi.org/10.3390/mps2010020
_version_ 1783413707271831552
author Kwon, Jane
Lee, Dong Joon
Kocher, Mallory
Kim, Yong-Il
Wu, Te-Ju
Whitley, John
Ko, Ching-Chang
author_facet Kwon, Jane
Lee, Dong Joon
Kocher, Mallory
Kim, Yong-Il
Wu, Te-Ju
Whitley, John
Ko, Ching-Chang
author_sort Kwon, Jane
collection PubMed
description A major drawback of nanocomposite scaffolds in bone tissue engineering is dimensional shrinkage after the fabrication process. Shrinkage yields gaps between the scaffold and host bone in the defect site and eventually causes failure in osteointegration by micromovement. The present study was conducted using titanium (Ti) mesh and Gelfoam(®) to prevent radial and axial micromovement, respectively. A critical-sized defect (CSD) was created in the center of the calvarium of Sprague Dawley rats to implant porous polydopamine-laced hydroxyapatite collagen calcium silicate (HCCS-PDA), a novel nanocomposite scaffold. Gelfoam(®) was applied around the edge of the defect, and then the HCCS-PDA scaffold was inserted in the defect area. Ti mesh was placed between the periosteum and skin right, above the inserted scaffold site. There were two test groups, with a fixture (Gelfoam(®) and Ti mesh) and without a fixture, each group contained five animals. The rats were sacrificed after three months post-operation. The explanted calvaria underwent micro-CT scanning and a push-out test to quantify osteointegration and mechanical strength between the scaffold and host bone. Histological analysis of undecalcified bone was performed by grinding resin infiltrated calvaria blocks to prepare 10 μm slices. Osteointegration was higher in the group with fixation than without fixation. Movement of the HCCS-PDA scaffold in the gap resulted in diminished osteointegration. With fixation, the movement was inhibited and osteointegration became prominent. Here we present a successful method of preventing axial and radial movement of scaffolds using Gelfoam(®) and Ti mesh. Applying this fixture, we expect that an HCCS-PDA scaffold can repair CSD more effectively.
format Online
Article
Text
id pubmed-6481059
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64810592019-05-31 The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration Kwon, Jane Lee, Dong Joon Kocher, Mallory Kim, Yong-Il Wu, Te-Ju Whitley, John Ko, Ching-Chang Methods Protoc Article A major drawback of nanocomposite scaffolds in bone tissue engineering is dimensional shrinkage after the fabrication process. Shrinkage yields gaps between the scaffold and host bone in the defect site and eventually causes failure in osteointegration by micromovement. The present study was conducted using titanium (Ti) mesh and Gelfoam(®) to prevent radial and axial micromovement, respectively. A critical-sized defect (CSD) was created in the center of the calvarium of Sprague Dawley rats to implant porous polydopamine-laced hydroxyapatite collagen calcium silicate (HCCS-PDA), a novel nanocomposite scaffold. Gelfoam(®) was applied around the edge of the defect, and then the HCCS-PDA scaffold was inserted in the defect area. Ti mesh was placed between the periosteum and skin right, above the inserted scaffold site. There were two test groups, with a fixture (Gelfoam(®) and Ti mesh) and without a fixture, each group contained five animals. The rats were sacrificed after three months post-operation. The explanted calvaria underwent micro-CT scanning and a push-out test to quantify osteointegration and mechanical strength between the scaffold and host bone. Histological analysis of undecalcified bone was performed by grinding resin infiltrated calvaria blocks to prepare 10 μm slices. Osteointegration was higher in the group with fixation than without fixation. Movement of the HCCS-PDA scaffold in the gap resulted in diminished osteointegration. With fixation, the movement was inhibited and osteointegration became prominent. Here we present a successful method of preventing axial and radial movement of scaffolds using Gelfoam(®) and Ti mesh. Applying this fixture, we expect that an HCCS-PDA scaffold can repair CSD more effectively. MDPI 2019-02-26 /pmc/articles/PMC6481059/ /pubmed/31164601 http://dx.doi.org/10.3390/mps2010020 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kwon, Jane
Lee, Dong Joon
Kocher, Mallory
Kim, Yong-Il
Wu, Te-Ju
Whitley, John
Ko, Ching-Chang
The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title_full The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title_fullStr The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title_full_unstemmed The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title_short The Inhibition of Radial and Axial Micromovement of Bone Scaffold with Gelfoam(®) and Titanium Mesh Fixation and Its Effects on Osteointegration
title_sort inhibition of radial and axial micromovement of bone scaffold with gelfoam(®) and titanium mesh fixation and its effects on osteointegration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481059/
https://www.ncbi.nlm.nih.gov/pubmed/31164601
http://dx.doi.org/10.3390/mps2010020
work_keys_str_mv AT kwonjane theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT leedongjoon theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kochermallory theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kimyongil theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT wuteju theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT whitleyjohn theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kochingchang theinhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kwonjane inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT leedongjoon inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kochermallory inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kimyongil inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT wuteju inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT whitleyjohn inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration
AT kochingchang inhibitionofradialandaxialmicromovementofbonescaffoldwithgelfoamandtitaniummeshfixationanditseffectsonosteointegration