Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet

Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic a...

Descripción completa

Detalles Bibliográficos
Autores principales: Pirola, S., Jarral, O. A., O'Regan, D. P., Asimakopoulos, G., Anderson, J. R., Pepper, J. R., Athanasiou, T., Xu, X. Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AIP Publishing LLC 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481743/
https://www.ncbi.nlm.nih.gov/pubmed/31069298
http://dx.doi.org/10.1063/1.5011960
_version_ 1783413785910837248
author Pirola, S.
Jarral, O. A.
O'Regan, D. P.
Asimakopoulos, G.
Anderson, J. R.
Pepper, J. R.
Athanasiou, T.
Xu, X. Y.
author_facet Pirola, S.
Jarral, O. A.
O'Regan, D. P.
Asimakopoulos, G.
Anderson, J. R.
Pepper, J. R.
Athanasiou, T.
Xu, X. Y.
author_sort Pirola, S.
collection PubMed
description Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic aorta based on patient-specific images, with a particular focus on patients with an abnormal aortic valve. Two cases were studied: one presenting a severe aortic valve stenosis and the other with a mechanical valve. For both aorta models, three inlet BCs were compared; these included the flat profile and 1D through-plane velocity and 3D phase-contrast magnetic resonance imaging derived velocity profiles, with the latter being used for benchmarking. Our results showed that peak and mean velocities at the proximal end of the ascending aorta were underestimated by up to 41% when the secondary flow components were neglected. The results for helical flow descriptors highlighted the strong influence of secondary velocities on the helical flow structure in the AAo. Differences in all wall shear stress (WSS)-derived indices were much more pronounced in the AAo and aortic arch (AA) than in the descending aorta (DAo). Overall, this study demonstrates that using 3D velocity profiles as inlet BC is essential for patient-specific analysis of hemodynamics and WSS in the AAo and AA in the presence of an abnormal aortic valve. However, predicted flow in the DAo is less sensitive to the secondary velocities imposed at the inlet; hence, the 1D through-plane profile could be a sufficient inlet BC for studies focusing on distal regions of the thoracic aorta.
format Online
Article
Text
id pubmed-6481743
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher AIP Publishing LLC
record_format MEDLINE/PubMed
spelling pubmed-64817432019-05-08 Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet Pirola, S. Jarral, O. A. O'Regan, D. P. Asimakopoulos, G. Anderson, J. R. Pepper, J. R. Athanasiou, T. Xu, X. Y. APL Bioeng Articles Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic aorta based on patient-specific images, with a particular focus on patients with an abnormal aortic valve. Two cases were studied: one presenting a severe aortic valve stenosis and the other with a mechanical valve. For both aorta models, three inlet BCs were compared; these included the flat profile and 1D through-plane velocity and 3D phase-contrast magnetic resonance imaging derived velocity profiles, with the latter being used for benchmarking. Our results showed that peak and mean velocities at the proximal end of the ascending aorta were underestimated by up to 41% when the secondary flow components were neglected. The results for helical flow descriptors highlighted the strong influence of secondary velocities on the helical flow structure in the AAo. Differences in all wall shear stress (WSS)-derived indices were much more pronounced in the AAo and aortic arch (AA) than in the descending aorta (DAo). Overall, this study demonstrates that using 3D velocity profiles as inlet BC is essential for patient-specific analysis of hemodynamics and WSS in the AAo and AA in the presence of an abnormal aortic valve. However, predicted flow in the DAo is less sensitive to the secondary velocities imposed at the inlet; hence, the 1D through-plane profile could be a sufficient inlet BC for studies focusing on distal regions of the thoracic aorta. AIP Publishing LLC 2018-03-16 /pmc/articles/PMC6481743/ /pubmed/31069298 http://dx.doi.org/10.1063/1.5011960 Text en © 2018 Author(s). 2473-2877/2018/2(2)/026101/14 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Articles
Pirola, S.
Jarral, O. A.
O'Regan, D. P.
Asimakopoulos, G.
Anderson, J. R.
Pepper, J. R.
Athanasiou, T.
Xu, X. Y.
Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title_full Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title_fullStr Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title_full_unstemmed Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title_short Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
title_sort computational study of aortic hemodynamics for patients with an abnormal aortic valve: the importance of secondary flow at the ascending aorta inlet
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481743/
https://www.ncbi.nlm.nih.gov/pubmed/31069298
http://dx.doi.org/10.1063/1.5011960
work_keys_str_mv AT pirolas computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT jarraloa computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT oregandp computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT asimakopoulosg computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT andersonjr computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT pepperjr computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT athanasiout computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet
AT xuxy computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet