Cargando…
Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AIP Publishing LLC
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481743/ https://www.ncbi.nlm.nih.gov/pubmed/31069298 http://dx.doi.org/10.1063/1.5011960 |
_version_ | 1783413785910837248 |
---|---|
author | Pirola, S. Jarral, O. A. O'Regan, D. P. Asimakopoulos, G. Anderson, J. R. Pepper, J. R. Athanasiou, T. Xu, X. Y. |
author_facet | Pirola, S. Jarral, O. A. O'Regan, D. P. Asimakopoulos, G. Anderson, J. R. Pepper, J. R. Athanasiou, T. Xu, X. Y. |
author_sort | Pirola, S. |
collection | PubMed |
description | Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic aorta based on patient-specific images, with a particular focus on patients with an abnormal aortic valve. Two cases were studied: one presenting a severe aortic valve stenosis and the other with a mechanical valve. For both aorta models, three inlet BCs were compared; these included the flat profile and 1D through-plane velocity and 3D phase-contrast magnetic resonance imaging derived velocity profiles, with the latter being used for benchmarking. Our results showed that peak and mean velocities at the proximal end of the ascending aorta were underestimated by up to 41% when the secondary flow components were neglected. The results for helical flow descriptors highlighted the strong influence of secondary velocities on the helical flow structure in the AAo. Differences in all wall shear stress (WSS)-derived indices were much more pronounced in the AAo and aortic arch (AA) than in the descending aorta (DAo). Overall, this study demonstrates that using 3D velocity profiles as inlet BC is essential for patient-specific analysis of hemodynamics and WSS in the AAo and AA in the presence of an abnormal aortic valve. However, predicted flow in the DAo is less sensitive to the secondary velocities imposed at the inlet; hence, the 1D through-plane profile could be a sufficient inlet BC for studies focusing on distal regions of the thoracic aorta. |
format | Online Article Text |
id | pubmed-6481743 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | AIP Publishing LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-64817432019-05-08 Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet Pirola, S. Jarral, O. A. O'Regan, D. P. Asimakopoulos, G. Anderson, J. R. Pepper, J. R. Athanasiou, T. Xu, X. Y. APL Bioeng Articles Blood flow in the aorta is helical, but most computational studies ignore the presence of secondary flow components at the ascending aorta (AAo) inlet. The aim of this study is to ascertain the importance of inlet boundary conditions (BCs) in computational analysis of flow patterns in the thoracic aorta based on patient-specific images, with a particular focus on patients with an abnormal aortic valve. Two cases were studied: one presenting a severe aortic valve stenosis and the other with a mechanical valve. For both aorta models, three inlet BCs were compared; these included the flat profile and 1D through-plane velocity and 3D phase-contrast magnetic resonance imaging derived velocity profiles, with the latter being used for benchmarking. Our results showed that peak and mean velocities at the proximal end of the ascending aorta were underestimated by up to 41% when the secondary flow components were neglected. The results for helical flow descriptors highlighted the strong influence of secondary velocities on the helical flow structure in the AAo. Differences in all wall shear stress (WSS)-derived indices were much more pronounced in the AAo and aortic arch (AA) than in the descending aorta (DAo). Overall, this study demonstrates that using 3D velocity profiles as inlet BC is essential for patient-specific analysis of hemodynamics and WSS in the AAo and AA in the presence of an abnormal aortic valve. However, predicted flow in the DAo is less sensitive to the secondary velocities imposed at the inlet; hence, the 1D through-plane profile could be a sufficient inlet BC for studies focusing on distal regions of the thoracic aorta. AIP Publishing LLC 2018-03-16 /pmc/articles/PMC6481743/ /pubmed/31069298 http://dx.doi.org/10.1063/1.5011960 Text en © 2018 Author(s). 2473-2877/2018/2(2)/026101/14 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Articles Pirola, S. Jarral, O. A. O'Regan, D. P. Asimakopoulos, G. Anderson, J. R. Pepper, J. R. Athanasiou, T. Xu, X. Y. Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title | Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title_full | Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title_fullStr | Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title_full_unstemmed | Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title_short | Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet |
title_sort | computational study of aortic hemodynamics for patients with an abnormal aortic valve: the importance of secondary flow at the ascending aorta inlet |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6481743/ https://www.ncbi.nlm.nih.gov/pubmed/31069298 http://dx.doi.org/10.1063/1.5011960 |
work_keys_str_mv | AT pirolas computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT jarraloa computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT oregandp computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT asimakopoulosg computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT andersonjr computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT pepperjr computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT athanasiout computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet AT xuxy computationalstudyofaortichemodynamicsforpatientswithanabnormalaorticvalvetheimportanceofsecondaryflowattheascendingaortainlet |