Cargando…
Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients
AIM: The purpose of the study is to evaluate and compare the horizontal mandibular positions recorded between intraoral conventional tracer and intraoral digital tracer in upright and supine position. MATERIALS AND METHODS: Twenty-four edentulous patients with well-formed ridge and adequate interarc...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6482625/ https://www.ncbi.nlm.nih.gov/pubmed/31040550 http://dx.doi.org/10.4103/jips.jips_269_18 |
_version_ | 1783413922547630080 |
---|---|
author | Abbad, Nikhil Bharat Srivastava, Rajeev Choukse, Vivek Sharma, Vandana |
author_facet | Abbad, Nikhil Bharat Srivastava, Rajeev Choukse, Vivek Sharma, Vandana |
author_sort | Abbad, Nikhil Bharat |
collection | PubMed |
description | AIM: The purpose of the study is to evaluate and compare the horizontal mandibular positions recorded between intraoral conventional tracer and intraoral digital tracer in upright and supine position. MATERIALS AND METHODS: Twenty-four edentulous patients with well-formed ridge and adequate interarch distance space were selected. MATLAB software was assimilated with intraoral digital tracer and was utilized in the study for recording the horizontal movements of the mandible, i.e., gothic arch tracing by intraoral digital tracer and was observed on a laptop with the help of MATLAB Software. For each subject, multiple mandibular readings were recorded and analyzed through software, and similar readings were recorded with conventional intraoral tracers. The comparison between intraoral conventional tracer and intraoral digital tracer was done to assess the reliability. Moreover, the consistency of recording horizontal mandibular position was also compared between upright and supine position. RESULTS: The data were procured and utilized in comparison for different positions revealed statistically significant difference by using Student's Paired t-test. The test resulted in supine position better compared to upright position (P = 0.0001). The association between supine position with upright position was calculated using Fischer's exact test, and it was also found to be statistically significant (P = 0.002). The Pearson's Correlation analysis was performed to check the agreement between upright and supine position and very weak downhill correlation (r(2)= −0.130) was observed between the two variables. CONCLUSION: On evaluation and comparison of horizontal mandibular position, it was found that the intraoral digital tracing technique is more valid compared to conventional intraoral tracer technique. It was also observed that the consistency of reproducibility in recording horizontal mandibular position in supine position is significantly higher than upright position. |
format | Online Article Text |
id | pubmed-6482625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-64826252020-04-01 Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients Abbad, Nikhil Bharat Srivastava, Rajeev Choukse, Vivek Sharma, Vandana J Indian Prosthodont Soc Original Article AIM: The purpose of the study is to evaluate and compare the horizontal mandibular positions recorded between intraoral conventional tracer and intraoral digital tracer in upright and supine position. MATERIALS AND METHODS: Twenty-four edentulous patients with well-formed ridge and adequate interarch distance space were selected. MATLAB software was assimilated with intraoral digital tracer and was utilized in the study for recording the horizontal movements of the mandible, i.e., gothic arch tracing by intraoral digital tracer and was observed on a laptop with the help of MATLAB Software. For each subject, multiple mandibular readings were recorded and analyzed through software, and similar readings were recorded with conventional intraoral tracers. The comparison between intraoral conventional tracer and intraoral digital tracer was done to assess the reliability. Moreover, the consistency of recording horizontal mandibular position was also compared between upright and supine position. RESULTS: The data were procured and utilized in comparison for different positions revealed statistically significant difference by using Student's Paired t-test. The test resulted in supine position better compared to upright position (P = 0.0001). The association between supine position with upright position was calculated using Fischer's exact test, and it was also found to be statistically significant (P = 0.002). The Pearson's Correlation analysis was performed to check the agreement between upright and supine position and very weak downhill correlation (r(2)= −0.130) was observed between the two variables. CONCLUSION: On evaluation and comparison of horizontal mandibular position, it was found that the intraoral digital tracing technique is more valid compared to conventional intraoral tracer technique. It was also observed that the consistency of reproducibility in recording horizontal mandibular position in supine position is significantly higher than upright position. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6482625/ /pubmed/31040550 http://dx.doi.org/10.4103/jips.jips_269_18 Text en Copyright: © 2019 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Abbad, Nikhil Bharat Srivastava, Rajeev Choukse, Vivek Sharma, Vandana Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title | Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title_full | Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title_fullStr | Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title_full_unstemmed | Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title_short | Validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
title_sort | validity and reliability of intraoral conventional tracer and intraoral digital tracer in different positions for recording horizontal jaw relation in edentulous patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6482625/ https://www.ncbi.nlm.nih.gov/pubmed/31040550 http://dx.doi.org/10.4103/jips.jips_269_18 |
work_keys_str_mv | AT abbadnikhilbharat validityandreliabilityofintraoralconventionaltracerandintraoraldigitaltracerindifferentpositionsforrecordinghorizontaljawrelationinedentulouspatients AT srivastavarajeev validityandreliabilityofintraoralconventionaltracerandintraoraldigitaltracerindifferentpositionsforrecordinghorizontaljawrelationinedentulouspatients AT chouksevivek validityandreliabilityofintraoralconventionaltracerandintraoraldigitaltracerindifferentpositionsforrecordinghorizontaljawrelationinedentulouspatients AT sharmavandana validityandreliabilityofintraoralconventionaltracerandintraoraldigitaltracerindifferentpositionsforrecordinghorizontaljawrelationinedentulouspatients |