Cargando…

Highly sensitive detection of influenza virus with SERS aptasensor

Highly sensitive and rapid technology of surface enhanced Raman scattering (SERS) was applied to create aptasensors for influenza virus detection. SERS achieves 10(6)−10(9) times signal amplification, yielding excellent sensitivity, whereas aptamers to hemagglutinin provide a specific recognition of...

Descripción completa

Detalles Bibliográficos
Autores principales: Kukushkin, Vladimir I., Ivanov, Nikita M., Novoseltseva, Anastasia A., Gambaryan, Alexandra S., Yaminsky, Igor V., Kopylov, Alexey M., Zavyalova, Elena G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6483365/
https://www.ncbi.nlm.nih.gov/pubmed/31022287
http://dx.doi.org/10.1371/journal.pone.0216247
_version_ 1783414014319001600
author Kukushkin, Vladimir I.
Ivanov, Nikita M.
Novoseltseva, Anastasia A.
Gambaryan, Alexandra S.
Yaminsky, Igor V.
Kopylov, Alexey M.
Zavyalova, Elena G.
author_facet Kukushkin, Vladimir I.
Ivanov, Nikita M.
Novoseltseva, Anastasia A.
Gambaryan, Alexandra S.
Yaminsky, Igor V.
Kopylov, Alexey M.
Zavyalova, Elena G.
author_sort Kukushkin, Vladimir I.
collection PubMed
description Highly sensitive and rapid technology of surface enhanced Raman scattering (SERS) was applied to create aptasensors for influenza virus detection. SERS achieves 10(6)−10(9) times signal amplification, yielding excellent sensitivity, whereas aptamers to hemagglutinin provide a specific recognition of the influenza virus. Aptamer RHA0385 was demonstrated to have essentially broad strain-specificity toward both recombinant hemagglutinins and the whole viruses. To achieve high sensitivity, a sandwich of primary aptamers, influenza virus and secondary aptamers was assembled. Primary aptamers were attached to metal particles of a SERS substrate, and influenza viruses were captured and bound with secondary aptamers labelled with Raman-active molecules. The signal was affected by the concentration of both primary and secondary aptamers. The limit of detection was as low as 1 · 10(−4) hemagglutination units per probe as tested for the H3N2 virus (A/England/42/72). Aptamer-based sensors provided recognition of various influenza viral strains, including H1, H3, and H5 hemagglutinin subtypes. Therefore, the aptasensors could be applied for fast and low-cost strain-independent determination of influenza viruses.
format Online
Article
Text
id pubmed-6483365
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-64833652019-05-09 Highly sensitive detection of influenza virus with SERS aptasensor Kukushkin, Vladimir I. Ivanov, Nikita M. Novoseltseva, Anastasia A. Gambaryan, Alexandra S. Yaminsky, Igor V. Kopylov, Alexey M. Zavyalova, Elena G. PLoS One Research Article Highly sensitive and rapid technology of surface enhanced Raman scattering (SERS) was applied to create aptasensors for influenza virus detection. SERS achieves 10(6)−10(9) times signal amplification, yielding excellent sensitivity, whereas aptamers to hemagglutinin provide a specific recognition of the influenza virus. Aptamer RHA0385 was demonstrated to have essentially broad strain-specificity toward both recombinant hemagglutinins and the whole viruses. To achieve high sensitivity, a sandwich of primary aptamers, influenza virus and secondary aptamers was assembled. Primary aptamers were attached to metal particles of a SERS substrate, and influenza viruses were captured and bound with secondary aptamers labelled with Raman-active molecules. The signal was affected by the concentration of both primary and secondary aptamers. The limit of detection was as low as 1 · 10(−4) hemagglutination units per probe as tested for the H3N2 virus (A/England/42/72). Aptamer-based sensors provided recognition of various influenza viral strains, including H1, H3, and H5 hemagglutinin subtypes. Therefore, the aptasensors could be applied for fast and low-cost strain-independent determination of influenza viruses. Public Library of Science 2019-04-25 /pmc/articles/PMC6483365/ /pubmed/31022287 http://dx.doi.org/10.1371/journal.pone.0216247 Text en © 2019 Kukushkin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kukushkin, Vladimir I.
Ivanov, Nikita M.
Novoseltseva, Anastasia A.
Gambaryan, Alexandra S.
Yaminsky, Igor V.
Kopylov, Alexey M.
Zavyalova, Elena G.
Highly sensitive detection of influenza virus with SERS aptasensor
title Highly sensitive detection of influenza virus with SERS aptasensor
title_full Highly sensitive detection of influenza virus with SERS aptasensor
title_fullStr Highly sensitive detection of influenza virus with SERS aptasensor
title_full_unstemmed Highly sensitive detection of influenza virus with SERS aptasensor
title_short Highly sensitive detection of influenza virus with SERS aptasensor
title_sort highly sensitive detection of influenza virus with sers aptasensor
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6483365/
https://www.ncbi.nlm.nih.gov/pubmed/31022287
http://dx.doi.org/10.1371/journal.pone.0216247
work_keys_str_mv AT kukushkinvladimiri highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT ivanovnikitam highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT novoseltsevaanastasiaa highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT gambaryanalexandras highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT yaminskyigorv highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT kopylovalexeym highlysensitivedetectionofinfluenzaviruswithsersaptasensor
AT zavyalovaelenag highlysensitivedetectionofinfluenzaviruswithsersaptasensor