Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India

Neonatal hyperbilirubinemia is a common problem with potentiality to cause irreversible brain damage. Reduction of serum bilirubin level is essential to minimize such damage. Compact fluorescent tubes, halogen bulbs, fiber optic blankets, and LEDs are commonly used light sources for phototherapy wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Gutta, Sreesravya, Shenoy, Janardhan, Kamath, Sowmini P., Mithra, Prasanna, Baliga, B. Shantharam, Sarpangala, Muralikeshava, Srinivasan, Mukund
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6487143/
https://www.ncbi.nlm.nih.gov/pubmed/31111060
http://dx.doi.org/10.1155/2019/6274719
_version_ 1783414451192463360
author Gutta, Sreesravya
Shenoy, Janardhan
Kamath, Sowmini P.
Mithra, Prasanna
Baliga, B. Shantharam
Sarpangala, Muralikeshava
Srinivasan, Mukund
author_facet Gutta, Sreesravya
Shenoy, Janardhan
Kamath, Sowmini P.
Mithra, Prasanna
Baliga, B. Shantharam
Sarpangala, Muralikeshava
Srinivasan, Mukund
author_sort Gutta, Sreesravya
collection PubMed
description Neonatal hyperbilirubinemia is a common problem with potentiality to cause irreversible brain damage. Reduction of serum bilirubin level is essential to minimize such damage. Compact fluorescent tubes, halogen bulbs, fiber optic blankets, and LEDs are commonly used light sources for phototherapy with varying efficacies. This study aimed at evaluating the effect of LED versus conventional phototherapy on (a) rate of reduction in total serum bilirubin levels, (b) effect on urinary lumirubin excretion, and (c) comparing side effects of phototherapies among neonates with hyperbilirubinemia. In this randomized control trial, 166 neonates ≥ 35 weeks of age requiring phototherapy were recruited and further divided into 2 groups [LED (83) and conventional (83)] by using computer generated random numbers. Serial total serum bilirubin levels and random urinary lumirubin levels were collected and side effects of phototherapy were noted. Rate of fall in total serum bilirubin levels (TSB, μmol/L/hour) and random urinary lumirubin levels were computed. Data were collected using a pretested proforma. Analysis was done with Statistical Package for Social Sciences (SPSS) version 11.5. Independent sample “t” test and Chi-square tests were used with p value of <0.05 being significant. Significant difference was documented in mean rate of decrease of TSB (μmol/L/hour) in LED group (5.3 ± 2.91) when compared to conventional group (3.76 ± 2.39) (p <0.001). A significant increase in mean random urinary lumirubin levels (arbitrary units) was observed in LED group (129.01 ± 33.18) when compared to conventional group (114.44 ± 44.84) (p = 0.021). Side effects were minimal and comparable in both groups. This study concludes the rates of decrease in total serum bilirubin levels and increase in urinary lumirubin levels were significant with LED when compared with conventional phototherapy, implying LED to be more efficacious.
format Online
Article
Text
id pubmed-6487143
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-64871432019-05-20 Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India Gutta, Sreesravya Shenoy, Janardhan Kamath, Sowmini P. Mithra, Prasanna Baliga, B. Shantharam Sarpangala, Muralikeshava Srinivasan, Mukund Biomed Res Int Research Article Neonatal hyperbilirubinemia is a common problem with potentiality to cause irreversible brain damage. Reduction of serum bilirubin level is essential to minimize such damage. Compact fluorescent tubes, halogen bulbs, fiber optic blankets, and LEDs are commonly used light sources for phototherapy with varying efficacies. This study aimed at evaluating the effect of LED versus conventional phototherapy on (a) rate of reduction in total serum bilirubin levels, (b) effect on urinary lumirubin excretion, and (c) comparing side effects of phototherapies among neonates with hyperbilirubinemia. In this randomized control trial, 166 neonates ≥ 35 weeks of age requiring phototherapy were recruited and further divided into 2 groups [LED (83) and conventional (83)] by using computer generated random numbers. Serial total serum bilirubin levels and random urinary lumirubin levels were collected and side effects of phototherapy were noted. Rate of fall in total serum bilirubin levels (TSB, μmol/L/hour) and random urinary lumirubin levels were computed. Data were collected using a pretested proforma. Analysis was done with Statistical Package for Social Sciences (SPSS) version 11.5. Independent sample “t” test and Chi-square tests were used with p value of <0.05 being significant. Significant difference was documented in mean rate of decrease of TSB (μmol/L/hour) in LED group (5.3 ± 2.91) when compared to conventional group (3.76 ± 2.39) (p <0.001). A significant increase in mean random urinary lumirubin levels (arbitrary units) was observed in LED group (129.01 ± 33.18) when compared to conventional group (114.44 ± 44.84) (p = 0.021). Side effects were minimal and comparable in both groups. This study concludes the rates of decrease in total serum bilirubin levels and increase in urinary lumirubin levels were significant with LED when compared with conventional phototherapy, implying LED to be more efficacious. Hindawi 2019-04-11 /pmc/articles/PMC6487143/ /pubmed/31111060 http://dx.doi.org/10.1155/2019/6274719 Text en Copyright © 2019 Sreesravya Gutta et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gutta, Sreesravya
Shenoy, Janardhan
Kamath, Sowmini P.
Mithra, Prasanna
Baliga, B. Shantharam
Sarpangala, Muralikeshava
Srinivasan, Mukund
Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title_full Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title_fullStr Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title_full_unstemmed Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title_short Light Emitting Diode (LED) Phototherapy versus Conventional Phototherapy in Neonatal Hyperbilirubinemia: A Single Blinded Randomized Control Trial from Coastal India
title_sort light emitting diode (led) phototherapy versus conventional phototherapy in neonatal hyperbilirubinemia: a single blinded randomized control trial from coastal india
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6487143/
https://www.ncbi.nlm.nih.gov/pubmed/31111060
http://dx.doi.org/10.1155/2019/6274719
work_keys_str_mv AT guttasreesravya lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT shenoyjanardhan lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT kamathsowminip lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT mithraprasanna lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT baligabshantharam lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT sarpangalamuralikeshava lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia
AT srinivasanmukund lightemittingdiodeledphototherapyversusconventionalphototherapyinneonatalhyperbilirubinemiaasingleblindedrandomizedcontroltrialfromcoastalindia