Cargando…
Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland
INTRODUCTION: Minimally invasive techniques of mitral valve (MV) repair have been increasingly used in recent years. Transapical implantation of artificial chordae on a beating heart under 2D/3D transesophageal echocardiographic guidance with the NeoChord DS1000 device is a new surgical treatment of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6488838/ https://www.ncbi.nlm.nih.gov/pubmed/31043981 http://dx.doi.org/10.5114/aic.2019.81438 |
_version_ | 1783414721258455040 |
---|---|
author | Kurnicka, Katarzyna Wróbel, Krzysztof Zdończyk, Olga Bielecki, Maksymilian Juraszyński, Zbigniew Biederman, Andrzej Pruszczyk, Piotr |
author_facet | Kurnicka, Katarzyna Wróbel, Krzysztof Zdończyk, Olga Bielecki, Maksymilian Juraszyński, Zbigniew Biederman, Andrzej Pruszczyk, Piotr |
author_sort | Kurnicka, Katarzyna |
collection | PubMed |
description | INTRODUCTION: Minimally invasive techniques of mitral valve (MV) repair have been increasingly used in recent years. Transapical implantation of artificial chordae on a beating heart under 2D/3D transesophageal echocardiographic guidance with the NeoChord DS1000 device is a new surgical treatment of degenerative mitral regurgitation (MR). AIM: To evaluate early results of MV repair with the NeoChord DS1000 device in the first group of consecutive patients operated on in Poland. MATERIAL AND METHODS: Twenty-one patients with severe MR due to posterior leaflet prolapse (81% male; mean age: 60.7 ±12.7 years) underwent MV repair with the NeoChord DS1000 system. There were 12 (57.1%) patients with type A (an isolated central prolapse/flail), 8 (38.1%) patients with type B (multisegment disease/flail) and 1 (4.8%) patient with type C (posterior/paracommisural area) MV prolapse. A flail leaflet was present in 12 (57.1%) patients. The median number of neochords was 3 (2–6). We assessed by echocardiography left-sided heart morphology and evaluated MR degree before and 6 months after chords implantation. RESULTS: Early procedural success was achieved in 100% of patients. At the 6-month follow-up nonsignificant MR (trace and mild) was detected in 17 (81.0%) patients, while moderate MR was detected in 4 (19.0%) patients; mean values of left-sided heart dimensions and volumes, mitral E and E’ velocity of lateral MV annulus significantly decreased. CONCLUSIONS: A novel procedure with the NeoChord DS1000 device is feasible in properly selected patients, and results in a significant reduction of MR degree and left ventricle and left atrium reverse remodeling at the 6-month follow-up. |
format | Online Article Text |
id | pubmed-6488838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-64888382019-05-01 Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland Kurnicka, Katarzyna Wróbel, Krzysztof Zdończyk, Olga Bielecki, Maksymilian Juraszyński, Zbigniew Biederman, Andrzej Pruszczyk, Piotr Postepy Kardiol Interwencyjnej Original Paper INTRODUCTION: Minimally invasive techniques of mitral valve (MV) repair have been increasingly used in recent years. Transapical implantation of artificial chordae on a beating heart under 2D/3D transesophageal echocardiographic guidance with the NeoChord DS1000 device is a new surgical treatment of degenerative mitral regurgitation (MR). AIM: To evaluate early results of MV repair with the NeoChord DS1000 device in the first group of consecutive patients operated on in Poland. MATERIAL AND METHODS: Twenty-one patients with severe MR due to posterior leaflet prolapse (81% male; mean age: 60.7 ±12.7 years) underwent MV repair with the NeoChord DS1000 system. There were 12 (57.1%) patients with type A (an isolated central prolapse/flail), 8 (38.1%) patients with type B (multisegment disease/flail) and 1 (4.8%) patient with type C (posterior/paracommisural area) MV prolapse. A flail leaflet was present in 12 (57.1%) patients. The median number of neochords was 3 (2–6). We assessed by echocardiography left-sided heart morphology and evaluated MR degree before and 6 months after chords implantation. RESULTS: Early procedural success was achieved in 100% of patients. At the 6-month follow-up nonsignificant MR (trace and mild) was detected in 17 (81.0%) patients, while moderate MR was detected in 4 (19.0%) patients; mean values of left-sided heart dimensions and volumes, mitral E and E’ velocity of lateral MV annulus significantly decreased. CONCLUSIONS: A novel procedure with the NeoChord DS1000 device is feasible in properly selected patients, and results in a significant reduction of MR degree and left ventricle and left atrium reverse remodeling at the 6-month follow-up. Termedia Publishing House 2019-01-21 2019 /pmc/articles/PMC6488838/ /pubmed/31043981 http://dx.doi.org/10.5114/aic.2019.81438 Text en Copyright: © 2019 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Original Paper Kurnicka, Katarzyna Wróbel, Krzysztof Zdończyk, Olga Bielecki, Maksymilian Juraszyński, Zbigniew Biederman, Andrzej Pruszczyk, Piotr Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title | Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title_full | Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title_fullStr | Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title_full_unstemmed | Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title_short | Early echocardiographic results of transapical off-pump mitral valve repair with the NeoChord DS1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in Poland |
title_sort | early echocardiographic results of transapical off-pump mitral valve repair with the neochord ds1000 device in patients with severe mitral regurgitation due to posterior leaflet prolapse: first experiences in poland |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6488838/ https://www.ncbi.nlm.nih.gov/pubmed/31043981 http://dx.doi.org/10.5114/aic.2019.81438 |
work_keys_str_mv | AT kurnickakatarzyna earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT wrobelkrzysztof earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT zdonczykolga earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT bieleckimaksymilian earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT juraszynskizbigniew earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT biedermanandrzej earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland AT pruszczykpiotr earlyechocardiographicresultsoftransapicaloffpumpmitralvalverepairwiththeneochordds1000deviceinpatientswithseveremitralregurgitationduetoposteriorleafletprolapsefirstexperiencesinpoland |