Cargando…

Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities

BACKGROUND: This study aimed to assess the effect of exposure parameters such as milliampere (mA) and field of view (FOV) of cone beam computed tomography (CBCT) on a metal artifact of dental implants placed in different bone densities. METHODS: A total of 27 bone blocks with different densities (ni...

Descripción completa

Detalles Bibliográficos
Autores principales: Shokri, Abbas, Jamalpour, Mohammad Reza, Khavid, Atefeh, Mohseni, Zeinab, Sadeghi, Masoud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6489302/
https://www.ncbi.nlm.nih.gov/pubmed/31035955
http://dx.doi.org/10.1186/s12880-019-0334-4
_version_ 1783414796977176576
author Shokri, Abbas
Jamalpour, Mohammad Reza
Khavid, Atefeh
Mohseni, Zeinab
Sadeghi, Masoud
author_facet Shokri, Abbas
Jamalpour, Mohammad Reza
Khavid, Atefeh
Mohseni, Zeinab
Sadeghi, Masoud
author_sort Shokri, Abbas
collection PubMed
description BACKGROUND: This study aimed to assess the effect of exposure parameters such as milliampere (mA) and field of view (FOV) of cone beam computed tomography (CBCT) on a metal artifact of dental implants placed in different bone densities. METHODS: A total of 27 bone blocks with different densities (nine were type 1, nine were types 2 and 3, and nine were type 4) were used in this in vitro, experimental study. These blocks were placed in mandibular wax models. The blocks were scanned after drilling (hole preparation) and after implant placement using Cranex3D imaging system with a 4 × 6 cm(2)and 6 × 8 cm(2) FOV and 4 and 10 mA. Gray value of the bone blocks was recorded before and after placement of implants. RESULTS: In general, irrespective of bone density, the amount of artifacts was lower in small FOV compared to large FOV (P < 0.05). Change of mA had no effect on metal artifacts (P > 0.05). Artifacts in type 4 bone were greater than in other bone types (P < 0.05). Difference between type 1 and types 2 and 3 was not significant (P > 0.05). CONCLUSION: According to the results of this study, Peri-implant artifacts were seen in all bone types; the amount of artifacts in type 4 bone was higher than that in other types. Size of FOV and bone density affect the metal artifacts around dental implants; so that a smaller FOV can be used to decrease metal artifacts.
format Online
Article
Text
id pubmed-6489302
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64893022019-06-04 Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities Shokri, Abbas Jamalpour, Mohammad Reza Khavid, Atefeh Mohseni, Zeinab Sadeghi, Masoud BMC Med Imaging Research Article BACKGROUND: This study aimed to assess the effect of exposure parameters such as milliampere (mA) and field of view (FOV) of cone beam computed tomography (CBCT) on a metal artifact of dental implants placed in different bone densities. METHODS: A total of 27 bone blocks with different densities (nine were type 1, nine were types 2 and 3, and nine were type 4) were used in this in vitro, experimental study. These blocks were placed in mandibular wax models. The blocks were scanned after drilling (hole preparation) and after implant placement using Cranex3D imaging system with a 4 × 6 cm(2)and 6 × 8 cm(2) FOV and 4 and 10 mA. Gray value of the bone blocks was recorded before and after placement of implants. RESULTS: In general, irrespective of bone density, the amount of artifacts was lower in small FOV compared to large FOV (P < 0.05). Change of mA had no effect on metal artifacts (P > 0.05). Artifacts in type 4 bone were greater than in other bone types (P < 0.05). Difference between type 1 and types 2 and 3 was not significant (P > 0.05). CONCLUSION: According to the results of this study, Peri-implant artifacts were seen in all bone types; the amount of artifacts in type 4 bone was higher than that in other types. Size of FOV and bone density affect the metal artifacts around dental implants; so that a smaller FOV can be used to decrease metal artifacts. BioMed Central 2019-04-29 /pmc/articles/PMC6489302/ /pubmed/31035955 http://dx.doi.org/10.1186/s12880-019-0334-4 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Shokri, Abbas
Jamalpour, Mohammad Reza
Khavid, Atefeh
Mohseni, Zeinab
Sadeghi, Masoud
Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title_full Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title_fullStr Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title_full_unstemmed Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title_short Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
title_sort effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6489302/
https://www.ncbi.nlm.nih.gov/pubmed/31035955
http://dx.doi.org/10.1186/s12880-019-0334-4
work_keys_str_mv AT shokriabbas effectofexposureparametersofconebeamcomputedtomographyonmetalartifactreductionaroundthedentalimplantsinvariousbonedensities
AT jamalpourmohammadreza effectofexposureparametersofconebeamcomputedtomographyonmetalartifactreductionaroundthedentalimplantsinvariousbonedensities
AT khavidatefeh effectofexposureparametersofconebeamcomputedtomographyonmetalartifactreductionaroundthedentalimplantsinvariousbonedensities
AT mohsenizeinab effectofexposureparametersofconebeamcomputedtomographyonmetalartifactreductionaroundthedentalimplantsinvariousbonedensities
AT sadeghimasoud effectofexposureparametersofconebeamcomputedtomographyonmetalartifactreductionaroundthedentalimplantsinvariousbonedensities