Cargando…
Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study
OBJECTIVE: The purpose of this study was to compare the marginal gap of E-max press, and E.max computer-aided design and computer-assisted manufacturing (CAD-CAM) lithium disilicate (LD) ceramic crowns fabricated by using conventional technique and CAD-CAM technique. MATERIALS AND METHODS: This was...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6489508/ https://www.ncbi.nlm.nih.gov/pubmed/31058069 http://dx.doi.org/10.4103/jispcd.JISPCD_18_19 |
_version_ | 1783414833459232768 |
---|---|
author | Elrashid, Afra Hassan AlKahtani, Amjad Hamod Alqahtani, Shatha Jarallah Alajmi, Nouf Bati Alsultan, Fatimah Hussain |
author_facet | Elrashid, Afra Hassan AlKahtani, Amjad Hamod Alqahtani, Shatha Jarallah Alajmi, Nouf Bati Alsultan, Fatimah Hussain |
author_sort | Elrashid, Afra Hassan |
collection | PubMed |
description | OBJECTIVE: The purpose of this study was to compare the marginal gap of E-max press, and E.max computer-aided design and computer-assisted manufacturing (CAD-CAM) lithium disilicate (LD) ceramic crowns fabricated by using conventional technique and CAD-CAM technique. MATERIALS AND METHODS: This was an in vitro experimental study carried out in Riyadh Elm University and King Saud University. A marginal gap of 30 LD crowns was evaluated by Stereomicroscopy. A total of 15 pressable LD (IPS E.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated by using conventional lost wax pattern method (Group A). Digital impressions of the prepared dies were scanned and transferred to the milling machine. IPS E.max CAD (IPS E-max, Ivoclar, Amherst, NY, USA) LD blocks in shade Vita A2 were then milled by using DWX-50 machine for CAD-CAM crowns (Group B). Descriptive statistics of mean and standard error of marginal gaps for both groups were recorded and compared by applying Mann–Whitney U-test. All the data were analyzed by using statistical analysis software SPSS version 21.0 (Armonk, NY, USA: IBM Corp). RESULTS: The LD crowns prepared by CAD-CAM technology (26.80 ± 3.4 μm) had significantly lower (P < 0.001) marginal gap than the LD pressed crowns (38.8 ± 2.3 μm) fabricated by conventional technique. The marginal gaps between CAD-CAM versus conventional groups exhibited significant differences at (42.68 μm vs. 52.46 μm, U = 51.500, P = 0.011), Mesiobuccal (15.94 μm vs. 30.13 μm, U = 45.500, P = 0.005), distolingual (26.70 μm vs. 43.86 μm, U = 63.500, P = 0.042), and distal (12.38 μm vs 31.45 μm, U = 47.500, P = 0.006). CONCLUSIONS: Within the limitations of the study, it can be concluded that LD all ceramic crowns fabricated by using CAD-CAM techniques showed lesser marginal gap and better marginal fit compared to the conventional technique. |
format | Online Article Text |
id | pubmed-6489508 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-64895082019-05-03 Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study Elrashid, Afra Hassan AlKahtani, Amjad Hamod Alqahtani, Shatha Jarallah Alajmi, Nouf Bati Alsultan, Fatimah Hussain J Int Soc Prev Community Dent Original Article OBJECTIVE: The purpose of this study was to compare the marginal gap of E-max press, and E.max computer-aided design and computer-assisted manufacturing (CAD-CAM) lithium disilicate (LD) ceramic crowns fabricated by using conventional technique and CAD-CAM technique. MATERIALS AND METHODS: This was an in vitro experimental study carried out in Riyadh Elm University and King Saud University. A marginal gap of 30 LD crowns was evaluated by Stereomicroscopy. A total of 15 pressable LD (IPS E.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated by using conventional lost wax pattern method (Group A). Digital impressions of the prepared dies were scanned and transferred to the milling machine. IPS E.max CAD (IPS E-max, Ivoclar, Amherst, NY, USA) LD blocks in shade Vita A2 were then milled by using DWX-50 machine for CAD-CAM crowns (Group B). Descriptive statistics of mean and standard error of marginal gaps for both groups were recorded and compared by applying Mann–Whitney U-test. All the data were analyzed by using statistical analysis software SPSS version 21.0 (Armonk, NY, USA: IBM Corp). RESULTS: The LD crowns prepared by CAD-CAM technology (26.80 ± 3.4 μm) had significantly lower (P < 0.001) marginal gap than the LD pressed crowns (38.8 ± 2.3 μm) fabricated by conventional technique. The marginal gaps between CAD-CAM versus conventional groups exhibited significant differences at (42.68 μm vs. 52.46 μm, U = 51.500, P = 0.011), Mesiobuccal (15.94 μm vs. 30.13 μm, U = 45.500, P = 0.005), distolingual (26.70 μm vs. 43.86 μm, U = 63.500, P = 0.042), and distal (12.38 μm vs 31.45 μm, U = 47.500, P = 0.006). CONCLUSIONS: Within the limitations of the study, it can be concluded that LD all ceramic crowns fabricated by using CAD-CAM techniques showed lesser marginal gap and better marginal fit compared to the conventional technique. Wolters Kluwer - Medknow 2019 2019-02-13 /pmc/articles/PMC6489508/ /pubmed/31058069 http://dx.doi.org/10.4103/jispcd.JISPCD_18_19 Text en Copyright: © 2019 Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Elrashid, Afra Hassan AlKahtani, Amjad Hamod Alqahtani, Shatha Jarallah Alajmi, Nouf Bati Alsultan, Fatimah Hussain Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title | Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title_full | Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title_fullStr | Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title_full_unstemmed | Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title_short | Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study |
title_sort | stereomicroscopic evaluation of marginal fit of e.max press and e.max computer-aided design and computer-assisted manufacturing lithium disilicate ceramic crowns: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6489508/ https://www.ncbi.nlm.nih.gov/pubmed/31058069 http://dx.doi.org/10.4103/jispcd.JISPCD_18_19 |
work_keys_str_mv | AT elrashidafrahassan stereomicroscopicevaluationofmarginalfitofemaxpressandemaxcomputeraideddesignandcomputerassistedmanufacturinglithiumdisilicateceramiccrownsaninvitrostudy AT alkahtaniamjadhamod stereomicroscopicevaluationofmarginalfitofemaxpressandemaxcomputeraideddesignandcomputerassistedmanufacturinglithiumdisilicateceramiccrownsaninvitrostudy AT alqahtanishathajarallah stereomicroscopicevaluationofmarginalfitofemaxpressandemaxcomputeraideddesignandcomputerassistedmanufacturinglithiumdisilicateceramiccrownsaninvitrostudy AT alajminoufbati stereomicroscopicevaluationofmarginalfitofemaxpressandemaxcomputeraideddesignandcomputerassistedmanufacturinglithiumdisilicateceramiccrownsaninvitrostudy AT alsultanfatimahhussain stereomicroscopicevaluationofmarginalfitofemaxpressandemaxcomputeraideddesignandcomputerassistedmanufacturinglithiumdisilicateceramiccrownsaninvitrostudy |