Cargando…

Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)

BACKGROUND: The durable polymer drug-eluting stents (DPDES) reduce the risk of repeated target vessel revascularisation (TLR) compared with BMS, but are associated with increased risk of late adverse events. In broadly inclusive populations, the biodegradable-polymer drug-eluting stents (BPDES) have...

Descripción completa

Detalles Bibliográficos
Autores principales: Verma, Bhupendra, Patel, Akhilesh, Katyal, Deepak, Singh, Vivek Raj, Singh, Avinash Kumar, Singh, Amrita, Kumar, Manu, Nagarkoti, Pratap
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Republic of Macedonia 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6490487/
https://www.ncbi.nlm.nih.gov/pubmed/31049089
http://dx.doi.org/10.3889/oamjms.2019.241
_version_ 1783414886162759680
author Verma, Bhupendra
Patel, Akhilesh
Katyal, Deepak
Singh, Vivek Raj
Singh, Avinash Kumar
Singh, Amrita
Kumar, Manu
Nagarkoti, Pratap
author_facet Verma, Bhupendra
Patel, Akhilesh
Katyal, Deepak
Singh, Vivek Raj
Singh, Avinash Kumar
Singh, Amrita
Kumar, Manu
Nagarkoti, Pratap
author_sort Verma, Bhupendra
collection PubMed
description BACKGROUND: The durable polymer drug-eluting stents (DPDES) reduce the risk of repeated target vessel revascularisation (TLR) compared with BMS, but are associated with increased risk of late adverse events. In broadly inclusive populations, the biodegradable-polymer drug-eluting stents (BPDES) have favourable results compared with DPDES in the long term. However, its use in primary angioplasty has not been adequately studied, and data of real-world clinical experience is lacking. AIM: Aim of this study was to assess the safety and efficacy of Yukon Choice PC Elite sirolimus-eluting stent (a novel BPDES) in STEMI patients undergoing primary angioplasty. METHODS: We have presented here one-year clinical follow-up data of the Yukon Choice PC Elite sirolimus-eluting stent in patients undergoing primary angioplasty. A total of 636 patients were enrolled in this single arm, prospective observational study from five centres. RESULTS: This multicentric observational study showed excellent safety and efficacy profile of the novel device at one year follow up. The device-oriented composite endpoint (DOCE) of cardiac death, target-vessel reinfarction, and target-lesion revascularisation (TLR) was 2.7%, and the patient-oriented composite endpoint (POCE) of all-cause death, any myocardial infarction, and any revascularisation was 4.2% at one year. Definite or probable stent thrombosis rate was 0.6%, and no events were recorded beyond 6 months of follow up. CONCLUSIONS: In patients with STEMI undergoing primary angioplasty, the use of Yukon Choice PC Elite (biodegradable polymer sirolimus-eluting stent) has excellent results at one year. It, therefore, represents an attractive alternative to second generation DES in this high-risk population.
format Online
Article
Text
id pubmed-6490487
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Republic of Macedonia
record_format MEDLINE/PubMed
spelling pubmed-64904872019-05-02 Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study) Verma, Bhupendra Patel, Akhilesh Katyal, Deepak Singh, Vivek Raj Singh, Avinash Kumar Singh, Amrita Kumar, Manu Nagarkoti, Pratap Open Access Maced J Med Sci Clinical Science BACKGROUND: The durable polymer drug-eluting stents (DPDES) reduce the risk of repeated target vessel revascularisation (TLR) compared with BMS, but are associated with increased risk of late adverse events. In broadly inclusive populations, the biodegradable-polymer drug-eluting stents (BPDES) have favourable results compared with DPDES in the long term. However, its use in primary angioplasty has not been adequately studied, and data of real-world clinical experience is lacking. AIM: Aim of this study was to assess the safety and efficacy of Yukon Choice PC Elite sirolimus-eluting stent (a novel BPDES) in STEMI patients undergoing primary angioplasty. METHODS: We have presented here one-year clinical follow-up data of the Yukon Choice PC Elite sirolimus-eluting stent in patients undergoing primary angioplasty. A total of 636 patients were enrolled in this single arm, prospective observational study from five centres. RESULTS: This multicentric observational study showed excellent safety and efficacy profile of the novel device at one year follow up. The device-oriented composite endpoint (DOCE) of cardiac death, target-vessel reinfarction, and target-lesion revascularisation (TLR) was 2.7%, and the patient-oriented composite endpoint (POCE) of all-cause death, any myocardial infarction, and any revascularisation was 4.2% at one year. Definite or probable stent thrombosis rate was 0.6%, and no events were recorded beyond 6 months of follow up. CONCLUSIONS: In patients with STEMI undergoing primary angioplasty, the use of Yukon Choice PC Elite (biodegradable polymer sirolimus-eluting stent) has excellent results at one year. It, therefore, represents an attractive alternative to second generation DES in this high-risk population. Republic of Macedonia 2019-04-14 /pmc/articles/PMC6490487/ /pubmed/31049089 http://dx.doi.org/10.3889/oamjms.2019.241 Text en Copyright: © 2019 Bhupendra Verma, Akhilesh Patel, Deepak Katyal, Vivek Raj Singh, Avinash Kumar Singh, Amrita Singh, Manu Kumar, Pratap Nagarkoti. http://creativecommons.org/licenses/CC BY-NC/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
spellingShingle Clinical Science
Verma, Bhupendra
Patel, Akhilesh
Katyal, Deepak
Singh, Vivek Raj
Singh, Avinash Kumar
Singh, Amrita
Kumar, Manu
Nagarkoti, Pratap
Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title_full Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title_fullStr Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title_full_unstemmed Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title_short Real World Experience of a Biodegradable Polymer Sirolimus-Eluting Stent (Yukon Choice PC Elite) in Patients with Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Angioplasty: A Multicentric Observational Study (The Elite India Study)
title_sort real world experience of a biodegradable polymer sirolimus-eluting stent (yukon choice pc elite) in patients with acute st-segment elevation myocardial infarction undergoing primary angioplasty: a multicentric observational study (the elite india study)
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6490487/
https://www.ncbi.nlm.nih.gov/pubmed/31049089
http://dx.doi.org/10.3889/oamjms.2019.241
work_keys_str_mv AT vermabhupendra realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT patelakhilesh realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT katyaldeepak realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT singhvivekraj realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT singhavinashkumar realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT singhamrita realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT kumarmanu realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy
AT nagarkotipratap realworldexperienceofabiodegradablepolymersirolimuselutingstentyukonchoicepceliteinpatientswithacutestsegmentelevationmyocardialinfarctionundergoingprimaryangioplastyamulticentricobservationalstudytheeliteindiastudy