Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

PURPOSE: Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on t...

Descripción completa

Detalles Bibliográficos
Autores principales: Şen, Nazmiye, Şermet, Ibrahim Bülent, Gürler, Nezahat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6491357/
https://www.ncbi.nlm.nih.gov/pubmed/31080571
http://dx.doi.org/10.4047/jap.2019.11.2.105
_version_ 1783414917505744896
author Şen, Nazmiye
Şermet, Ibrahim Bülent
Gürler, Nezahat
author_facet Şen, Nazmiye
Şermet, Ibrahim Bülent
Gürler, Nezahat
author_sort Şen, Nazmiye
collection PubMed
description PURPOSE: Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS: A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with 0.7 µL of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (α=.05). RESULTS: Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in µm) of the groups were in the range of 2.7–4.0 (IC-Zr), 1.8–5.3 (IC-Ti), 6.5–17.1 (IT-Zr), 5.4–12.0 (IT-Ti), 16.8–22.7 (EH-Zr), and 10.3–15.4 (EH-Ti). CONCLUSION: The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.
format Online
Article
Text
id pubmed-6491357
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-64913572019-05-10 Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs Şen, Nazmiye Şermet, Ibrahim Bülent Gürler, Nezahat J Adv Prosthodont Original Article PURPOSE: Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS: A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with 0.7 µL of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (α=.05). RESULTS: Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in µm) of the groups were in the range of 2.7–4.0 (IC-Zr), 1.8–5.3 (IC-Ti), 6.5–17.1 (IT-Zr), 5.4–12.0 (IT-Ti), 16.8–22.7 (EH-Zr), and 10.3–15.4 (EH-Ti). CONCLUSION: The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design. The Korean Academy of Prosthodontics 2019-04 2019-04-26 /pmc/articles/PMC6491357/ /pubmed/31080571 http://dx.doi.org/10.4047/jap.2019.11.2.105 Text en © 2019 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Şen, Nazmiye
Şermet, Ibrahim Bülent
Gürler, Nezahat
Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title_full Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title_fullStr Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title_full_unstemmed Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title_short Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
title_sort sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6491357/
https://www.ncbi.nlm.nih.gov/pubmed/31080571
http://dx.doi.org/10.4047/jap.2019.11.2.105
work_keys_str_mv AT sennazmiye sealingcapabilityandmarginalfitoftitaniumversuszirconiaabutmentswithdifferentconnectiondesigns
AT sermetibrahimbulent sealingcapabilityandmarginalfitoftitaniumversuszirconiaabutmentswithdifferentconnectiondesigns
AT gurlernezahat sealingcapabilityandmarginalfitoftitaniumversuszirconiaabutmentswithdifferentconnectiondesigns