Cargando…
Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry
The magnetic reversal behavior of a ferromagnet (FM) coupled through an FeMn antiferromagnet (AF) to a pinned ferromagnet has been investigated by polarized neutron reflectivity measurements. With FeMn as the AF layer it is found that there exists 90° interlayer coupling through this layer and that...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6491425/ https://www.ncbi.nlm.nih.gov/pubmed/31040356 http://dx.doi.org/10.1038/s41598-019-43251-1 |
_version_ | 1783414933271085056 |
---|---|
author | Zhan, X. Z. Li, G. Cai, J. W. Zhu, T. Cooper, J. F. K. Kinane, C. J. Langridge, S. |
author_facet | Zhan, X. Z. Li, G. Cai, J. W. Zhu, T. Cooper, J. F. K. Kinane, C. J. Langridge, S. |
author_sort | Zhan, X. Z. |
collection | PubMed |
description | The magnetic reversal behavior of a ferromagnet (FM) coupled through an FeMn antiferromagnet (AF) to a pinned ferromagnet has been investigated by polarized neutron reflectivity measurements. With FeMn as the AF layer it is found that there exists 90° interlayer coupling through this layer and that this plays a key role in the transfer of the exchange bias (EB) effect from the FM/AF interface to the AF/pinned-FM interface. Combined with Monte Carlo simulations, we demonstrate that the competition between the interlayer coupling and the anisotropy of the AF layer results in a control of the EB effect which has potential for device applications. |
format | Online Article Text |
id | pubmed-6491425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-64914252019-05-16 Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry Zhan, X. Z. Li, G. Cai, J. W. Zhu, T. Cooper, J. F. K. Kinane, C. J. Langridge, S. Sci Rep Article The magnetic reversal behavior of a ferromagnet (FM) coupled through an FeMn antiferromagnet (AF) to a pinned ferromagnet has been investigated by polarized neutron reflectivity measurements. With FeMn as the AF layer it is found that there exists 90° interlayer coupling through this layer and that this plays a key role in the transfer of the exchange bias (EB) effect from the FM/AF interface to the AF/pinned-FM interface. Combined with Monte Carlo simulations, we demonstrate that the competition between the interlayer coupling and the anisotropy of the AF layer results in a control of the EB effect which has potential for device applications. Nature Publishing Group UK 2019-04-30 /pmc/articles/PMC6491425/ /pubmed/31040356 http://dx.doi.org/10.1038/s41598-019-43251-1 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Zhan, X. Z. Li, G. Cai, J. W. Zhu, T. Cooper, J. F. K. Kinane, C. J. Langridge, S. Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title | Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title_full | Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title_fullStr | Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title_full_unstemmed | Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title_short | Probing the Transfer of the Exchange Bias Effect by Polarized Neutron Reflectometry |
title_sort | probing the transfer of the exchange bias effect by polarized neutron reflectometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6491425/ https://www.ncbi.nlm.nih.gov/pubmed/31040356 http://dx.doi.org/10.1038/s41598-019-43251-1 |
work_keys_str_mv | AT zhanxz probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT lig probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT caijw probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT zhut probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT cooperjfk probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT kinanecj probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry AT langridges probingthetransferoftheexchangebiaseffectbypolarizedneutronreflectometry |