Cargando…

A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI

PURPOSE: When using simultaneous multi‐slice (SMS) EPI for background suppressed (BGS) arterial spin labeling (ASL), correction of through‐plane motion could introduce artefacts, because the slices with most effective BGS are adjacent to slices with the least BGS. In this study, a new framework is p...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzuki, Yuriko, Okell, Thomas W., Chappell, Michael A., van Osch, Matthias J.P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6492089/
https://www.ncbi.nlm.nih.gov/pubmed/30311694
http://dx.doi.org/10.1002/mrm.27499
_version_ 1783415078543949824
author Suzuki, Yuriko
Okell, Thomas W.
Chappell, Michael A.
van Osch, Matthias J.P.
author_facet Suzuki, Yuriko
Okell, Thomas W.
Chappell, Michael A.
van Osch, Matthias J.P.
author_sort Suzuki, Yuriko
collection PubMed
description PURPOSE: When using simultaneous multi‐slice (SMS) EPI for background suppressed (BGS) arterial spin labeling (ASL), correction of through‐plane motion could introduce artefacts, because the slices with most effective BGS are adjacent to slices with the least BGS. In this study, a new framework is presented to correct for such artefacts. METHODS: The proposed framework consists of 3 steps: (1) homogenization of the static tissue signal over the different slices to eliminate most inter‐slice differences because of different levels of BGS, (2) application of motion correction, and (3) extraction of a perfusion‐weighted signal using a general linear model. The proposed framework was evaluated by simulations and a functional ASL study with intentional head motion. RESULTS: Simulation studies demonstrated that the strong signal differences between slices with the most and least effective BGS caused sub‐optimal estimation of motion parameters when through‐plane motion was present. Although use of the M(0) image as the reference for registration allowed 82% improvement of motion estimation for through‐plane motion, it still led to residual subtraction errors caused by different static tissue signal between control and label because of different BGS levels. By using our proposed framework, those problems were minimized, and the accuracy of CBF estimation was improved. Moreover, the functional ASL study showed improved detection of visual and motor activation when applying the framework as compared to conventional motion correction, as well as when motion correction was completely omitted. CONCLUSION: When combining BGS‐ASL with SMS‐EPI, particular attention is needed to avoid artefacts introduced by motion correction. With the proposed framework, these issues are minimized.
format Online
Article
Text
id pubmed-6492089
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64920892019-05-06 A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI Suzuki, Yuriko Okell, Thomas W. Chappell, Michael A. van Osch, Matthias J.P. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: When using simultaneous multi‐slice (SMS) EPI for background suppressed (BGS) arterial spin labeling (ASL), correction of through‐plane motion could introduce artefacts, because the slices with most effective BGS are adjacent to slices with the least BGS. In this study, a new framework is presented to correct for such artefacts. METHODS: The proposed framework consists of 3 steps: (1) homogenization of the static tissue signal over the different slices to eliminate most inter‐slice differences because of different levels of BGS, (2) application of motion correction, and (3) extraction of a perfusion‐weighted signal using a general linear model. The proposed framework was evaluated by simulations and a functional ASL study with intentional head motion. RESULTS: Simulation studies demonstrated that the strong signal differences between slices with the most and least effective BGS caused sub‐optimal estimation of motion parameters when through‐plane motion was present. Although use of the M(0) image as the reference for registration allowed 82% improvement of motion estimation for through‐plane motion, it still led to residual subtraction errors caused by different static tissue signal between control and label because of different BGS levels. By using our proposed framework, those problems were minimized, and the accuracy of CBF estimation was improved. Moreover, the functional ASL study showed improved detection of visual and motor activation when applying the framework as compared to conventional motion correction, as well as when motion correction was completely omitted. CONCLUSION: When combining BGS‐ASL with SMS‐EPI, particular attention is needed to avoid artefacts introduced by motion correction. With the proposed framework, these issues are minimized. John Wiley and Sons Inc. 2018-10-12 2019-03 /pmc/articles/PMC6492089/ /pubmed/30311694 http://dx.doi.org/10.1002/mrm.27499 Text en © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Suzuki, Yuriko
Okell, Thomas W.
Chappell, Michael A.
van Osch, Matthias J.P.
A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title_full A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title_fullStr A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title_full_unstemmed A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title_short A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice EPI
title_sort framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi‐slice epi
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6492089/
https://www.ncbi.nlm.nih.gov/pubmed/30311694
http://dx.doi.org/10.1002/mrm.27499
work_keys_str_mv AT suzukiyuriko aframeworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT okellthomasw aframeworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT chappellmichaela aframeworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT vanoschmatthiasjp aframeworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT suzukiyuriko frameworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT okellthomasw frameworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT chappellmichaela frameworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi
AT vanoschmatthiasjp frameworkformotioncorrectionofbackgroundsuppressedarterialspinlabelingperfusionimagesacquiredwithsimultaneousmultisliceepi