Cargando…
An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes
The availability of material for experimental studies is a key constraint in the development of full‐scale bioprocesses. This is especially true for the later stages in a bioprocess sequence such as purification and formulation, where the product is at a relatively high concentration and traditional...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6492246/ https://www.ncbi.nlm.nih.gov/pubmed/30411315 http://dx.doi.org/10.1002/bit.26859 |
_version_ | 1783415109130911744 |
---|---|
author | Fernandez‐Cerezo, Lara Rayat, Andrea C. M. E. Chatel, Alex Pollard, Jennifer M. Lye, Gary J. Hoare, Michael |
author_facet | Fernandez‐Cerezo, Lara Rayat, Andrea C. M. E. Chatel, Alex Pollard, Jennifer M. Lye, Gary J. Hoare, Michael |
author_sort | Fernandez‐Cerezo, Lara |
collection | PubMed |
description | The availability of material for experimental studies is a key constraint in the development of full‐scale bioprocesses. This is especially true for the later stages in a bioprocess sequence such as purification and formulation, where the product is at a relatively high concentration and traditional scale‐down models can require significant volumes. Using a combination of critical flow regime analysis, bioprocess modelling, and experimentation, ultra scale‐down (USD) methods can yield bioprocess information using only millilitre quantities before embarking on highly demanding full‐scale studies. In this study the performance of a pilot‐scale tangential flow filtration (TFF) system based on a membrane flat‐sheet cassette using pumped flow was predicted by devising an USD device comprising a stirred cell using a rotating disc. The USD device operates with just 2.1 cm(2) of membrane area and, for example, just 1.7 mL of feed for diafiltration studies. The novel features of the design involve optimisation of the disc location and the membrane configuration to yield an approximately uniform shear rate. This is characterised using computational fluid dynamics for a defined layer above the membrane surface. A pilot‐scale TFF device operating at ~500‐fold larger feed volume and membrane area was characterised in terms of the shear rate derived from flow rate‐pressure drop relationships for the cassette. Good agreement was achieved between the USD and TFF devices for the flux and resistance values at equivalent average shear rates for a monoclonal antibody diafiltration stage. |
format | Online Article Text |
id | pubmed-6492246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64922462019-05-07 An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes Fernandez‐Cerezo, Lara Rayat, Andrea C. M. E. Chatel, Alex Pollard, Jennifer M. Lye, Gary J. Hoare, Michael Biotechnol Bioeng ARTICLES The availability of material for experimental studies is a key constraint in the development of full‐scale bioprocesses. This is especially true for the later stages in a bioprocess sequence such as purification and formulation, where the product is at a relatively high concentration and traditional scale‐down models can require significant volumes. Using a combination of critical flow regime analysis, bioprocess modelling, and experimentation, ultra scale‐down (USD) methods can yield bioprocess information using only millilitre quantities before embarking on highly demanding full‐scale studies. In this study the performance of a pilot‐scale tangential flow filtration (TFF) system based on a membrane flat‐sheet cassette using pumped flow was predicted by devising an USD device comprising a stirred cell using a rotating disc. The USD device operates with just 2.1 cm(2) of membrane area and, for example, just 1.7 mL of feed for diafiltration studies. The novel features of the design involve optimisation of the disc location and the membrane configuration to yield an approximately uniform shear rate. This is characterised using computational fluid dynamics for a defined layer above the membrane surface. A pilot‐scale TFF device operating at ~500‐fold larger feed volume and membrane area was characterised in terms of the shear rate derived from flow rate‐pressure drop relationships for the cassette. Good agreement was achieved between the USD and TFF devices for the flux and resistance values at equivalent average shear rates for a monoclonal antibody diafiltration stage. John Wiley and Sons Inc. 2019-01-04 2019-03 /pmc/articles/PMC6492246/ /pubmed/30411315 http://dx.doi.org/10.1002/bit.26859 Text en © 2018 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | ARTICLES Fernandez‐Cerezo, Lara Rayat, Andrea C. M. E. Chatel, Alex Pollard, Jennifer M. Lye, Gary J. Hoare, Michael An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title | An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title_full | An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title_fullStr | An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title_full_unstemmed | An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title_short | An ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
title_sort | ultra scale‐down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes |
topic | ARTICLES |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6492246/ https://www.ncbi.nlm.nih.gov/pubmed/30411315 http://dx.doi.org/10.1002/bit.26859 |
work_keys_str_mv | AT fernandezcerezolara anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT rayatandreacme anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT chatelalex anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT pollardjenniferm anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT lyegaryj anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT hoaremichael anultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT fernandezcerezolara ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT rayatandreacme ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT chatelalex ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT pollardjenniferm ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT lyegaryj ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes AT hoaremichael ultrascaledownmethodtoinvestigatemonoclonalantibodyprocessingduringtangentialflowfiltrationusingultrafiltrationmembranes |