Cargando…
Impact of atrial rhythm on pulmonary vein signals in cryoballoon ablation – Sinus rhythm predicts real-time observation of pulmonary vein isolation
PURPOSE: Real-time observation of pulmonary vein (PV) potentials with a spiral mapping catheter has emerged as a key electrogram-based procedural parameter to estimate lesion quality and titrate cryoenergy application during PV isolation (PVI) with the cryoballoon. Whether correct PV electrogram int...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6495074/ https://www.ncbi.nlm.nih.gov/pubmed/31065585 http://dx.doi.org/10.1016/j.ijcha.2019.100353 |
Sumario: | PURPOSE: Real-time observation of pulmonary vein (PV) potentials with a spiral mapping catheter has emerged as a key electrogram-based procedural parameter to estimate lesion quality and titrate cryoenergy application during PV isolation (PVI) with the cryoballoon. Whether correct PV electrogram interpretation and thus PVI real-time observation rate depends on atrial rhythm during cryoballoon PVI is unknown. We compared observation rates of time-to PV isolation (TTI) during sinus rhythm (SR group) and during atrial fibrillation (AFib group) in cryoballoon PVI. METHODS: We prospectively included 157 consecutive patients undergoing cryoballoon PVI and compared the incidence of PVI real-time recording of each pulmonary vein during SR and in AFib. RESULTS: Overall PVI real-time observation rate was 82.1% (491/598 PV) with significantly higher TTI observation rate in the SR group (315/365 PV, 86.3%) compared to the AFib group (176/233 PV, 75.5%; p < 0.001). Per vein analysis demonstrated that only TTI observation rate in the left superior pulmonary vein (LSPV) was significantly higher during SR (85/92, 92.4%) compared to AFib (37/54, 68.5%; p < 0.001). Regression analysis revealed that atrial rhythm is a strong and independent predictor of PVI real-time observation in the LSPV with an odds ratio of 4.98 (95%-CI: 1.86–13.34, p = 0.001) to detect TTI during SR. CONCLUSIONS: Our results demonstrate that correct interpretation of PV electrograms and thus PVI real-time observation is more likely in SR than in AFib. Hence, cardioversion of patients in AFib at the beginning of the procedure should be considered to yield higher PVI real-time observation rates facilitating TTI guided cryoenergy titration. |
---|