Cargando…

Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction

PURPOSE: The purpose of this study was to evaluate the positions of femoral bone sockets and tibial bone tunnels made with the rectangular retro-dilator (RRD), which we manufactured for anterior cruciate ligament reconstruction (ACLR) with a bone-patella tendon-bone (BPTB) graft which is fixed into...

Descripción completa

Detalles Bibliográficos
Autores principales: Hayashi, Hiroteru, Kurosaka, Daisaburo, Saito, Mitsuru, Ikeda, Ryo, Kubota, Daisuke, Kayama, Tomohiro, Hyakutake, Takashi, Marumo, Keishi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6497238/
https://www.ncbi.nlm.nih.gov/pubmed/31048889
http://dx.doi.org/10.1371/journal.pone.0215778
_version_ 1783415432739291136
author Hayashi, Hiroteru
Kurosaka, Daisaburo
Saito, Mitsuru
Ikeda, Ryo
Kubota, Daisuke
Kayama, Tomohiro
Hyakutake, Takashi
Marumo, Keishi
author_facet Hayashi, Hiroteru
Kurosaka, Daisaburo
Saito, Mitsuru
Ikeda, Ryo
Kubota, Daisuke
Kayama, Tomohiro
Hyakutake, Takashi
Marumo, Keishi
author_sort Hayashi, Hiroteru
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the positions of femoral bone sockets and tibial bone tunnels made with the rectangular retro-dilator (RRD), which we manufactured for anterior cruciate ligament reconstruction (ACLR) with a bone-patella tendon-bone (BPTB) graft which is fixed into the rectangular bone socket and tunnel made at anatomical ACL insertion sites. METHODS: 42 patients who had undergone ACLR with BPTB using the RRD were evaluated to assess bone socket and tunnel positions by the quadrant method and Magnussen classification using three-dimensional (3-D) CT. Intra-operative complications were also investigated in all patients. RESULTS: 3-D CT of the operated knee joints using the RRD showed that the bone socket and tunnel were placed in anatomical positions. In the quadrant method, the mean position of the femoral bone socket aperture was located at 22.0 ± 4.2% along the Blumensaat’s line, and 37.4 ± 7.2% across the posterior condylar rim. The mean positions of the tibial bone tunnel aperture were 37.7 ± 5.2% and 46.1 ± 2.2% antero-posteriorly and medio-laterally, respectively. In addition, according to the Magnussen classification, 39 cases were evaluated as type 1, and almost all were located behind the lateral intercondylar ridge (also known as the resident’s ridge). 3 cases were classified as type 2, which overlapped with the resident’s ridge. A partial fracture of BPTB bone fragment was observed in 2 patients, but no serious complications including neurovascular injury were observed. CONCLUSION: The study indicates that the use of RRD achieves a safe anatomical reconstruction of the ACL.
format Online
Article
Text
id pubmed-6497238
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-64972382019-05-17 Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction Hayashi, Hiroteru Kurosaka, Daisaburo Saito, Mitsuru Ikeda, Ryo Kubota, Daisuke Kayama, Tomohiro Hyakutake, Takashi Marumo, Keishi PLoS One Research Article PURPOSE: The purpose of this study was to evaluate the positions of femoral bone sockets and tibial bone tunnels made with the rectangular retro-dilator (RRD), which we manufactured for anterior cruciate ligament reconstruction (ACLR) with a bone-patella tendon-bone (BPTB) graft which is fixed into the rectangular bone socket and tunnel made at anatomical ACL insertion sites. METHODS: 42 patients who had undergone ACLR with BPTB using the RRD were evaluated to assess bone socket and tunnel positions by the quadrant method and Magnussen classification using three-dimensional (3-D) CT. Intra-operative complications were also investigated in all patients. RESULTS: 3-D CT of the operated knee joints using the RRD showed that the bone socket and tunnel were placed in anatomical positions. In the quadrant method, the mean position of the femoral bone socket aperture was located at 22.0 ± 4.2% along the Blumensaat’s line, and 37.4 ± 7.2% across the posterior condylar rim. The mean positions of the tibial bone tunnel aperture were 37.7 ± 5.2% and 46.1 ± 2.2% antero-posteriorly and medio-laterally, respectively. In addition, according to the Magnussen classification, 39 cases were evaluated as type 1, and almost all were located behind the lateral intercondylar ridge (also known as the resident’s ridge). 3 cases were classified as type 2, which overlapped with the resident’s ridge. A partial fracture of BPTB bone fragment was observed in 2 patients, but no serious complications including neurovascular injury were observed. CONCLUSION: The study indicates that the use of RRD achieves a safe anatomical reconstruction of the ACL. Public Library of Science 2019-05-02 /pmc/articles/PMC6497238/ /pubmed/31048889 http://dx.doi.org/10.1371/journal.pone.0215778 Text en © 2019 Hayashi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hayashi, Hiroteru
Kurosaka, Daisaburo
Saito, Mitsuru
Ikeda, Ryo
Kubota, Daisuke
Kayama, Tomohiro
Hyakutake, Takashi
Marumo, Keishi
Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title_full Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title_fullStr Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title_full_unstemmed Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title_short Positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
title_sort positioning the femoral bone socket and the tibial bone tunnel using a rectangular retro-dilator in anterior cruciate ligament reconstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6497238/
https://www.ncbi.nlm.nih.gov/pubmed/31048889
http://dx.doi.org/10.1371/journal.pone.0215778
work_keys_str_mv AT hayashihiroteru positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT kurosakadaisaburo positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT saitomitsuru positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT ikedaryo positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT kubotadaisuke positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT kayamatomohiro positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT hyakutaketakashi positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction
AT marumokeishi positioningthefemoralbonesocketandthetibialbonetunnelusingarectangularretrodilatorinanteriorcruciateligamentreconstruction