Cargando…

Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes

PURPOSE: To evaluate the optical quality and tear-film dynamics in patients with aqueous-deficient or evaporative subtype of dry eye disease (DED). METHODS: Twenty-five aqueous-deficient dry eye (ADDE) patients, 25 DED patients with meibomian gland dysfunction (MGD), and 25 healthy subjects were inc...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Fen, Jiang, Feng, Lu, Yan, Xue, Chun Yan, Zhu, Xiao Min, Wu, Yan, Huang, Zhen Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6498932/
https://www.ncbi.nlm.nih.gov/pubmed/31007216
http://dx.doi.org/10.4103/ijo.IJO_1278_18
_version_ 1783415711082741760
author Ye, Fen
Jiang, Feng
Lu, Yan
Xue, Chun Yan
Zhu, Xiao Min
Wu, Yan
Huang, Zhen Ping
author_facet Ye, Fen
Jiang, Feng
Lu, Yan
Xue, Chun Yan
Zhu, Xiao Min
Wu, Yan
Huang, Zhen Ping
author_sort Ye, Fen
collection PubMed
description PURPOSE: To evaluate the optical quality and tear-film dynamics in patients with aqueous-deficient or evaporative subtype of dry eye disease (DED). METHODS: Twenty-five aqueous-deficient dry eye (ADDE) patients, 25 DED patients with meibomian gland dysfunction (MGD), and 25 healthy subjects were included in this study. Vision-related health-targeted quality of life was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Dynamic recording with a double-pass system (Optical Quality Analysis System [OQAS]) was performed in right eyes. Scattered light was measured as the objective scatter index (OSI) at 0.5-second intervals over 20 seconds without blinking. Then, we recorded OSI every 0.5 seconds within a 20-second period with the subjects asked to blink freely. Several parameters were established to evaluate the dynamic alterations of optical quality and the effects of blinks: OSI, OSI standard deviation (SD), ΔOSI, ΔOSI/time, blinking change (BC), and blinking frequency (BF). Additional clinical examination included tear film break-up time (BUT), Schirmer I test (SIT), fluorescein staining grade (FL), meibomian gland quality, meibomian gland expressibility, and meibomian gland drop-out. RESULTS: The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in DED patients than controls (P < 0.01, respectively). The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in patients with MGD than patients with ADDE (P < 0.01). In the MGD group, BUT, FL staining score, lid abnormality, meibomian gland expressibility, and meibomian gland drop-out were correlated with Δ OSI and Δ OSI/time. CONCLUSION: Dry eye patients with MGD had significant alterations of optical quality compared with ADDE patients. The double-pass system has potential to be a useful quantitative method to evaluate the optical quality and tear-film dynamics in patients with dry eye.
format Online
Article
Text
id pubmed-6498932
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-64989322019-05-08 Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes Ye, Fen Jiang, Feng Lu, Yan Xue, Chun Yan Zhu, Xiao Min Wu, Yan Huang, Zhen Ping Indian J Ophthalmol Original Article PURPOSE: To evaluate the optical quality and tear-film dynamics in patients with aqueous-deficient or evaporative subtype of dry eye disease (DED). METHODS: Twenty-five aqueous-deficient dry eye (ADDE) patients, 25 DED patients with meibomian gland dysfunction (MGD), and 25 healthy subjects were included in this study. Vision-related health-targeted quality of life was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Dynamic recording with a double-pass system (Optical Quality Analysis System [OQAS]) was performed in right eyes. Scattered light was measured as the objective scatter index (OSI) at 0.5-second intervals over 20 seconds without blinking. Then, we recorded OSI every 0.5 seconds within a 20-second period with the subjects asked to blink freely. Several parameters were established to evaluate the dynamic alterations of optical quality and the effects of blinks: OSI, OSI standard deviation (SD), ΔOSI, ΔOSI/time, blinking change (BC), and blinking frequency (BF). Additional clinical examination included tear film break-up time (BUT), Schirmer I test (SIT), fluorescein staining grade (FL), meibomian gland quality, meibomian gland expressibility, and meibomian gland drop-out. RESULTS: The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in DED patients than controls (P < 0.01, respectively). The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in patients with MGD than patients with ADDE (P < 0.01). In the MGD group, BUT, FL staining score, lid abnormality, meibomian gland expressibility, and meibomian gland drop-out were correlated with Δ OSI and Δ OSI/time. CONCLUSION: Dry eye patients with MGD had significant alterations of optical quality compared with ADDE patients. The double-pass system has potential to be a useful quantitative method to evaluate the optical quality and tear-film dynamics in patients with dry eye. Medknow Publications & Media Pvt Ltd 2019-05 /pmc/articles/PMC6498932/ /pubmed/31007216 http://dx.doi.org/10.4103/ijo.IJO_1278_18 Text en Copyright: © 2019 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ye, Fen
Jiang, Feng
Lu, Yan
Xue, Chun Yan
Zhu, Xiao Min
Wu, Yan
Huang, Zhen Ping
Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title_full Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title_fullStr Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title_full_unstemmed Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title_short Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
title_sort objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6498932/
https://www.ncbi.nlm.nih.gov/pubmed/31007216
http://dx.doi.org/10.4103/ijo.IJO_1278_18
work_keys_str_mv AT yefen objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT jiangfeng objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT luyan objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT xuechunyan objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT zhuxiaomin objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT wuyan objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes
AT huangzhenping objectiveopticalassessmentoftearfilmqualitydynamicsinpatientswithmeibomianglanddysfunctionandaqueousdeficientdryeyeopticalqualitychangesindifferentdryeyesubtypes