Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies

Advances in microfabrication technology have enabled the production of devices containing arrays of thousands of closely spaced recording electrodes, which afford subcellular resolution of electrical signals in neurons and neuronal networks. Rationalizing the electrode size and configuration in such...

Descripción completa

Detalles Bibliográficos
Autores principales: Viswam, Vijay, Obien, Marie Engelene J., Franke, Felix, Frey, Urs, Hierlemann, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6498989/
https://www.ncbi.nlm.nih.gov/pubmed/31105515
http://dx.doi.org/10.3389/fnins.2019.00385
_version_ 1783415724548554752
author Viswam, Vijay
Obien, Marie Engelene J.
Franke, Felix
Frey, Urs
Hierlemann, Andreas
author_facet Viswam, Vijay
Obien, Marie Engelene J.
Franke, Felix
Frey, Urs
Hierlemann, Andreas
author_sort Viswam, Vijay
collection PubMed
description Advances in microfabrication technology have enabled the production of devices containing arrays of thousands of closely spaced recording electrodes, which afford subcellular resolution of electrical signals in neurons and neuronal networks. Rationalizing the electrode size and configuration in such arrays demands consideration of application-specific requirements and inherent features of the electrodes. Tradeoffs among size, spatial density, sensitivity, noise, attenuation, and other factors are inevitable. Although recording extracellular signals from neurons with planar metal electrodes is fairly well established, the effects of the electrode characteristics on the quality and utility of recorded signals, especially for small, densely packed electrodes, have yet to be fully characterized. Here, we present a combined experimental and computational approach to elucidating how electrode size, and size-dependent parameters, such as impedance, baseline noise, and transmission characteristics, influence recorded neuronal signals. Using arrays containing platinum electrodes of different sizes, we experimentally evaluated the electrode performance in the recording of local field potentials (LFPs) and extracellular action potentials (EAPs) from the following cell preparations: acute brain slices, dissociated cell cultures, and organotypic slice cultures. Moreover, we simulated the potential spatial decay of point-current sources to investigate signal averaging using known signal sources. We demonstrated that the noise and signal attenuation depend more on the electrode impedance than on electrode size, per se, especially for electrodes <10 μm in width or diameter to achieve high-spatial-resolution readout. By minimizing electrode impedance of small electrodes (<10 μm) via surface modification, we could maximize the signal-to-noise ratio to electrically visualize the propagation of axonal EAPs and to isolate single-unit spikes. Due to the large amplitude of LFP signals, recording quality was high and nearly independent of electrode size. These findings should be of value in configuring in vitro and in vivo microelectrode arrays for extracellular recordings with high spatial resolution in various applications.
format Online
Article
Text
id pubmed-6498989
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-64989892019-05-17 Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies Viswam, Vijay Obien, Marie Engelene J. Franke, Felix Frey, Urs Hierlemann, Andreas Front Neurosci Neuroscience Advances in microfabrication technology have enabled the production of devices containing arrays of thousands of closely spaced recording electrodes, which afford subcellular resolution of electrical signals in neurons and neuronal networks. Rationalizing the electrode size and configuration in such arrays demands consideration of application-specific requirements and inherent features of the electrodes. Tradeoffs among size, spatial density, sensitivity, noise, attenuation, and other factors are inevitable. Although recording extracellular signals from neurons with planar metal electrodes is fairly well established, the effects of the electrode characteristics on the quality and utility of recorded signals, especially for small, densely packed electrodes, have yet to be fully characterized. Here, we present a combined experimental and computational approach to elucidating how electrode size, and size-dependent parameters, such as impedance, baseline noise, and transmission characteristics, influence recorded neuronal signals. Using arrays containing platinum electrodes of different sizes, we experimentally evaluated the electrode performance in the recording of local field potentials (LFPs) and extracellular action potentials (EAPs) from the following cell preparations: acute brain slices, dissociated cell cultures, and organotypic slice cultures. Moreover, we simulated the potential spatial decay of point-current sources to investigate signal averaging using known signal sources. We demonstrated that the noise and signal attenuation depend more on the electrode impedance than on electrode size, per se, especially for electrodes <10 μm in width or diameter to achieve high-spatial-resolution readout. By minimizing electrode impedance of small electrodes (<10 μm) via surface modification, we could maximize the signal-to-noise ratio to electrically visualize the propagation of axonal EAPs and to isolate single-unit spikes. Due to the large amplitude of LFP signals, recording quality was high and nearly independent of electrode size. These findings should be of value in configuring in vitro and in vivo microelectrode arrays for extracellular recordings with high spatial resolution in various applications. Frontiers Media S.A. 2019-04-26 /pmc/articles/PMC6498989/ /pubmed/31105515 http://dx.doi.org/10.3389/fnins.2019.00385 Text en Copyright © 2019 Viswam, Obien, Franke, Frey and Hierlemann. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Viswam, Vijay
Obien, Marie Engelene J.
Franke, Felix
Frey, Urs
Hierlemann, Andreas
Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title_full Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title_fullStr Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title_full_unstemmed Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title_short Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
title_sort optimal electrode size for multi-scale extracellular-potential recording from neuronal assemblies
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6498989/
https://www.ncbi.nlm.nih.gov/pubmed/31105515
http://dx.doi.org/10.3389/fnins.2019.00385
work_keys_str_mv AT viswamvijay optimalelectrodesizeformultiscaleextracellularpotentialrecordingfromneuronalassemblies
AT obienmarieengelenej optimalelectrodesizeformultiscaleextracellularpotentialrecordingfromneuronalassemblies
AT frankefelix optimalelectrodesizeformultiscaleextracellularpotentialrecordingfromneuronalassemblies
AT freyurs optimalelectrodesizeformultiscaleextracellularpotentialrecordingfromneuronalassemblies
AT hierlemannandreas optimalelectrodesizeformultiscaleextracellularpotentialrecordingfromneuronalassemblies