Cargando…
Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics
OBJECTIVES: This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED). DESIGN: Prospective cohort study. SETTING: Two tertiary EDs in Western Australia. PARTICIPANTS: 8...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6500093/ https://www.ncbi.nlm.nih.gov/pubmed/30944127 http://dx.doi.org/10.1136/bmjopen-2018-022278 |
_version_ | 1783415888868802560 |
---|---|
author | Carr, Peter J Rippey, James C R Cooke, Marie L Trevenen, Michelle L Higgins, Niall S Foale, Aileen S Rickard, Claire M |
author_facet | Carr, Peter J Rippey, James C R Cooke, Marie L Trevenen, Michelle L Higgins, Niall S Foale, Aileen S Rickard, Claire M |
author_sort | Carr, Peter J |
collection | PubMed |
description | OBJECTIVES: This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED). DESIGN: Prospective cohort study. SETTING: Two tertiary EDs in Western Australia. PARTICIPANTS: 879 ED patients. PRIMARY OUTCOME: To identify factors affecting FTIS using univariate and multivariate logistic regression modelling. We created four models: patient factors only; clinician factors only; products and technology factors only and all factors model. We assessed each model’s performance using area under the receiver operating characteristic curve. RESULTS: A total of 1201 PIVCs were inserted in 879 patients. The mean age was 60.3 (SD 22) years with slightly more females (52%). The FTIS rate was 73%, with 128 (15%) requiring a second attempt and 83 (9%) requiring three or more attempts. A small percentage (3%) had no recorded number of subsequent attempts. FTIS was related to the following patient factors: age (for a 1-year increase in age: OR 0.99, 95% CI 0.983 to 0.998; p=0.0097); and target vein palpability: (always palpable vs never palpable: OR 3.53 95% CI 1.64 to 7.60; only palpable with tourniquet vs never palpable: OR 2.20, 95% CI 1.06 to 4.57; p=0.0014). Clinician factors related to FTIS include: clinicians with greater confidence (p<0.0001) and insertion experience (301–1000 vs <301: OR 1.54, 95% CI 1.02 to 2.34; >1000 vs <301: OR 2.07, 95% CI 1.41 to 3.04; p=0.0011). The final all factors model combining patient factors; clinician factors and product and technology factors has greater discriminative ability than specific factors models. It has a sensitivity of 74.26%, specificity of 57.69%, positive predictive value of 82.87% and negative predictive value of 44.85%. CONCLUSION: A clinical decision, matching patients who have no palpable veins and are older, with clinicians with greater confidence and experience, will likely improve FTIS. TRIALREGISTRATION NUMBER: ANZCTRN12615000588594; Results. |
format | Online Article Text |
id | pubmed-6500093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-65000932019-05-21 Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics Carr, Peter J Rippey, James C R Cooke, Marie L Trevenen, Michelle L Higgins, Niall S Foale, Aileen S Rickard, Claire M BMJ Open Emergency Medicine OBJECTIVES: This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED). DESIGN: Prospective cohort study. SETTING: Two tertiary EDs in Western Australia. PARTICIPANTS: 879 ED patients. PRIMARY OUTCOME: To identify factors affecting FTIS using univariate and multivariate logistic regression modelling. We created four models: patient factors only; clinician factors only; products and technology factors only and all factors model. We assessed each model’s performance using area under the receiver operating characteristic curve. RESULTS: A total of 1201 PIVCs were inserted in 879 patients. The mean age was 60.3 (SD 22) years with slightly more females (52%). The FTIS rate was 73%, with 128 (15%) requiring a second attempt and 83 (9%) requiring three or more attempts. A small percentage (3%) had no recorded number of subsequent attempts. FTIS was related to the following patient factors: age (for a 1-year increase in age: OR 0.99, 95% CI 0.983 to 0.998; p=0.0097); and target vein palpability: (always palpable vs never palpable: OR 3.53 95% CI 1.64 to 7.60; only palpable with tourniquet vs never palpable: OR 2.20, 95% CI 1.06 to 4.57; p=0.0014). Clinician factors related to FTIS include: clinicians with greater confidence (p<0.0001) and insertion experience (301–1000 vs <301: OR 1.54, 95% CI 1.02 to 2.34; >1000 vs <301: OR 2.07, 95% CI 1.41 to 3.04; p=0.0011). The final all factors model combining patient factors; clinician factors and product and technology factors has greater discriminative ability than specific factors models. It has a sensitivity of 74.26%, specificity of 57.69%, positive predictive value of 82.87% and negative predictive value of 44.85%. CONCLUSION: A clinical decision, matching patients who have no palpable veins and are older, with clinicians with greater confidence and experience, will likely improve FTIS. TRIALREGISTRATION NUMBER: ANZCTRN12615000588594; Results. BMJ Publishing Group 2019-04-02 /pmc/articles/PMC6500093/ /pubmed/30944127 http://dx.doi.org/10.1136/bmjopen-2018-022278 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Emergency Medicine Carr, Peter J Rippey, James C R Cooke, Marie L Trevenen, Michelle L Higgins, Niall S Foale, Aileen S Rickard, Claire M Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title | Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title_full | Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title_fullStr | Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title_full_unstemmed | Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title_short | Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics |
title_sort | factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. a multicentre prospective cohort analysis of patient, clinician and product characteristics |
topic | Emergency Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6500093/ https://www.ncbi.nlm.nih.gov/pubmed/30944127 http://dx.doi.org/10.1136/bmjopen-2018-022278 |
work_keys_str_mv | AT carrpeterj factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT rippeyjamescr factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT cookemariel factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT trevenenmichellel factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT higginsnialls factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT foaleaileens factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics AT rickardclairem factorsassociatedwithperipheralintravenouscannulationfirsttimeinsertionsuccessintheemergencydepartmentamulticentreprospectivecohortanalysisofpatientclinicianandproductcharacteristics |