Cargando…

Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement

If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alt...

Descripción completa

Detalles Bibliográficos
Autores principales: Meyer, Carolin, van Gaalen, Kerstin, Leschinger, Tim, Scheyerer, Max J., Neiss, Wolfram F., Staat, Manfred, Müller, Lars P., Wegmann, Kilian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6501275/
https://www.ncbi.nlm.nih.gov/pubmed/31143778
http://dx.doi.org/10.1155/2019/9232813
_version_ 1783416083925958656
author Meyer, Carolin
van Gaalen, Kerstin
Leschinger, Tim
Scheyerer, Max J.
Neiss, Wolfram F.
Staat, Manfred
Müller, Lars P.
Wegmann, Kilian
author_facet Meyer, Carolin
van Gaalen, Kerstin
Leschinger, Tim
Scheyerer, Max J.
Neiss, Wolfram F.
Staat, Manfred
Müller, Lars P.
Wegmann, Kilian
author_sort Meyer, Carolin
collection PubMed
description If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features.
format Online
Article
Text
id pubmed-6501275
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-65012752019-05-29 Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement Meyer, Carolin van Gaalen, Kerstin Leschinger, Tim Scheyerer, Max J. Neiss, Wolfram F. Staat, Manfred Müller, Lars P. Wegmann, Kilian Biomed Res Int Research Article If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features. Hindawi 2019-04-22 /pmc/articles/PMC6501275/ /pubmed/31143778 http://dx.doi.org/10.1155/2019/9232813 Text en Copyright © 2019 Carolin Meyer et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Meyer, Carolin
van Gaalen, Kerstin
Leschinger, Tim
Scheyerer, Max J.
Neiss, Wolfram F.
Staat, Manfred
Müller, Lars P.
Wegmann, Kilian
Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title_full Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title_fullStr Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title_full_unstemmed Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title_short Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
title_sort kyphoplasty of osteoporotic fractured vertebrae: a finite element analysis about two types of cement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6501275/
https://www.ncbi.nlm.nih.gov/pubmed/31143778
http://dx.doi.org/10.1155/2019/9232813
work_keys_str_mv AT meyercarolin kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT vangaalenkerstin kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT leschingertim kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT scheyerermaxj kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT neisswolframf kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT staatmanfred kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT mullerlarsp kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement
AT wegmannkilian kyphoplastyofosteoporoticfracturedvertebraeafiniteelementanalysisabouttwotypesofcement