Cargando…

Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes

Background and aim: Labeled leukocytes with (99m)Tc-HMPAO are routinely used for infection imaging. Although cell labeling with (99m)Tc-HMPAO represents an imaging probe to detect infection sites, the diagnostic efficiency of the probe is largely influenced by cell manipulation, multidisciplinary in...

Descripción completa

Detalles Bibliográficos
Autores principales: Silvia, Migliari, Antonino, Sammartano, Carla, Cidda, Giorgio, Baldari, Maura, Scarlattei, Giulio, Serreli, Caterina, Ghetti, Silvia, Pipitone, Giuseppe, Lippi, Livia, Ruffini
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mattioli 1885 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502120/
https://www.ncbi.nlm.nih.gov/pubmed/30333459
http://dx.doi.org/10.23750/abm.v89i3.7064
_version_ 1783416211000786944
author Silvia, Migliari
Antonino, Sammartano
Carla, Cidda
Giorgio, Baldari
Maura, Scarlattei
Giulio, Serreli
Caterina, Ghetti
Silvia, Pipitone
Giuseppe, Lippi
Livia, Ruffini
author_facet Silvia, Migliari
Antonino, Sammartano
Carla, Cidda
Giorgio, Baldari
Maura, Scarlattei
Giulio, Serreli
Caterina, Ghetti
Silvia, Pipitone
Giuseppe, Lippi
Livia, Ruffini
author_sort Silvia, Migliari
collection PubMed
description Background and aim: Labeled leukocytes with (99m)Tc-HMPAO are routinely used for infection imaging. Although cell labeling with (99m)Tc-HMPAO represents an imaging probe to detect infection sites, the diagnostic efficiency of the probe is largely influenced by cell manipulation, multidisciplinary interventions (i.e., biologist, technicians) and available technology (i.e., SPECT, SPECT/CT). The aim of the study was to assess in vitro and in vivo accuracy of a comprehensive approach for quality assessment (QA) of all steps of the procedure. Methods: Radiochemical purity (RCP), pH, labeling efficiency (LE) were measured in 320 procedures. White Cell Viability Factor (WVF) was determined in consecutive blood samples. Images (490 studies) were scored using a 5-point scale. Training program was evaluated using a Learning Questionnaire and a score system. Results: Pre/post-labelling WVF was 0.99% (max value 1%) in all blood samples. LE (mean value 72%) and RCP (>80% until 55 minutes) yielded considerably high values. The vast majority of images were scored as diagnostic by three independent observer (90% with score ≥4). Conclusions: This method appears highly reproducible and easy to use in clinical routine for leukocyte labeling, especially when standardized training and total QA system are implemented. (www.actabiomedica.it)
format Online
Article
Text
id pubmed-6502120
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Mattioli 1885
record_format MEDLINE/PubMed
spelling pubmed-65021202019-05-08 Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes Silvia, Migliari Antonino, Sammartano Carla, Cidda Giorgio, Baldari Maura, Scarlattei Giulio, Serreli Caterina, Ghetti Silvia, Pipitone Giuseppe, Lippi Livia, Ruffini Acta Biomed Original Article Background and aim: Labeled leukocytes with (99m)Tc-HMPAO are routinely used for infection imaging. Although cell labeling with (99m)Tc-HMPAO represents an imaging probe to detect infection sites, the diagnostic efficiency of the probe is largely influenced by cell manipulation, multidisciplinary interventions (i.e., biologist, technicians) and available technology (i.e., SPECT, SPECT/CT). The aim of the study was to assess in vitro and in vivo accuracy of a comprehensive approach for quality assessment (QA) of all steps of the procedure. Methods: Radiochemical purity (RCP), pH, labeling efficiency (LE) were measured in 320 procedures. White Cell Viability Factor (WVF) was determined in consecutive blood samples. Images (490 studies) were scored using a 5-point scale. Training program was evaluated using a Learning Questionnaire and a score system. Results: Pre/post-labelling WVF was 0.99% (max value 1%) in all blood samples. LE (mean value 72%) and RCP (>80% until 55 minutes) yielded considerably high values. The vast majority of images were scored as diagnostic by three independent observer (90% with score ≥4). Conclusions: This method appears highly reproducible and easy to use in clinical routine for leukocyte labeling, especially when standardized training and total QA system are implemented. (www.actabiomedica.it) Mattioli 1885 2018 /pmc/articles/PMC6502120/ /pubmed/30333459 http://dx.doi.org/10.23750/abm.v89i3.7064 Text en Copyright: © 2018 ACTA BIO MEDICA SOCIETY OF MEDICINE AND NATURAL SCIENCES OF PARMA http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution 4.0 International License
spellingShingle Original Article
Silvia, Migliari
Antonino, Sammartano
Carla, Cidda
Giorgio, Baldari
Maura, Scarlattei
Giulio, Serreli
Caterina, Ghetti
Silvia, Pipitone
Giuseppe, Lippi
Livia, Ruffini
Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title_full Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title_fullStr Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title_full_unstemmed Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title_short Novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mTc-HMPAO labeled leukocytes
title_sort novel approach for quality assessment and improving diagnostic accuracy in cell-based infection imaging using (99)mtc-hmpao labeled leukocytes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502120/
https://www.ncbi.nlm.nih.gov/pubmed/30333459
http://dx.doi.org/10.23750/abm.v89i3.7064
work_keys_str_mv AT silviamigliari novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT antoninosammartano novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT carlacidda novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT giorgiobaldari novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT maurascarlattei novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT giulioserreli novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT caterinaghetti novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT silviapipitone novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT giuseppelippi novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes
AT liviaruffini novelapproachforqualityassessmentandimprovingdiagnosticaccuracyincellbasedinfectionimagingusing99mtchmpaolabeledleukocytes